By ABB
SKU
MPN
1SBL171101R8400
Weight
0.306 kg
The AFC16-04-00-84 is a 4-pole (4 N.C) - 690 V IEC or 600 V UL contactor withScrew terminals, mainly controlling power circuits up to 30 A (IEC AC-1) or 30 A UL general use. Within the AF platform, AFC contactors offer an optimized operating time for AC controlled applications with electromagnetic coil (control voltage : 110 V AC 50 Hz / 110 ... 120 V AC 60 Hz). AFC contactors have a block type design and can be easily extended with add-on auxiliary contact blocks and a wide range of additionnal accessories.
Technical Specifications
Dimensions
Product Net Width | 45 mm |
Product Net Depth / Length | 77 mm |
Product Net Height | 86 mm |
Product Net Weight | 0.306 kg |
Technical
Number of Main Contacts NO | 0 |
Number of Main Contacts NC | 4 |
Number of Auxiliary Contacts NO | 0 |
Number of Auxiliary Contacts NC | 0 |
Standards | IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CAN/CSA C22.2 No.60947-1, CAN/CSA C22.2 No.60947-4-1 |
Rated Operational Voltage | Main Circuit 690 V |
Rated Frequency (f) | Main Circuit 50 / 60 Hz |
Conventional Free-air Thermal Current (Ith) | acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 30 A |
Rated Operational Current AC-1 (Ie) | (690 V) 40 °C 30 A |
Rated Operational Current AC-1 (Ie) | (690 V) 60 °C 30 A |
Rated Operational Current AC-1 (Ie) | (690 V) 70 °C 26 A |
Rated Operational Current AC-3 (Ie) | (415 V) 60 °C 5.2 A |
Rated Operational Current AC-3 (Ie) | (440 V) 60 °C 5.7 A |
Rated Operational Current AC-3 (Ie) | (500 V) 60 °C 5.7 A |
Rated Operational Current AC-3 (Ie) | (690 V) 60 °C 5.1 A |
Rated Operational Current AC-3 (Ie) | (380 / 400 V) 60 °C 5.2 A |
Rated Operational Current AC-3 (Ie) | (220 / 230 / 240 V) 60 °C 4.9 A |
Rated Operational Power AC-3 (Pe) | (415 V) 2.2 kW |
Rated Operational Power AC-3 (Pe) | (440 V) 3 kW |
Rated Operational Power AC-3 (Pe) | (500 V) 3 kW |
Rated Operational Power AC-3 (Pe) | (690 V) 4 kW |
Rated Operational Power AC-3 (Pe) | (380 / 400 V) 2.2 kW |
Rated Operational Power AC-3 (Pe) | (220 / 230 / 240 V) 1.1 kW |
Rated Short-time Withstand Current Low Voltage (Icw) | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 150 A |
Rated Short-time Withstand Current Low Voltage (Icw) | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 35 A |
Rated Short-time Withstand Current Low Voltage (Icw) | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 60 A |
Rated Short-time Withstand Current Low Voltage (Icw) | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 300 A |
Rated Short-time Withstand Current Low Voltage (Icw) | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 80 A |
Maximum Breaking Capacity | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 A |
Maximum Breaking Capacity | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 106 A |
Maximum Electrical Switching Frequency | (AC-1) 600 cycles per hour |
Rated Insulation Voltage (Ui) | acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V |
Rated Insulation Voltage (Ui) | acc. to IEC 60947-5-1 and VDE 0110 (Gr. C) 690 V |
Rated Insulation Voltage (Ui) | acc. to UL/CSA 600 V |
Rated Impulse Withstand Voltage (Uimp) | 6 kV |
Maximum Mechanical Switching Frequency | 3600 cycles per hour |
Rated Control Circuit Voltage (Uc) | 50 Hz 110 V |
Rated Control Circuit Voltage (Uc) | 60 Hz 110 ... 120 V |
Coil Consumption | Average Holding Value 50 / 60 Hz 8 V·A |
Coil Consumption | Average Pull-in Value 50 Hz 70 V·A |
Coil Consumption | Average Pull-in Value 60 Hz 66 V·A |
Operate Time | Between Coil De-energization and NC Contact Closing 9 ... 20 ms |
Operate Time | Between Coil De-energization and NO Contact Opening 4 ... 18 ms |
Operate Time | Between Coil Energization and NC Contact Opening 7 ... 21 ms |
Operate Time | Between Coil Energization and NO Contact Closing 10 ... 26 ms |
Mounting on DIN Rail | TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 |
Mounting on DIN Rail | TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715 |
Mounting by Screws (not supplied) | 2 x M4 screws placed diagonally |
Connecting Capacity Main Circuit | Flexible with Ferrule 1/2x 0.75 ... 6 mm² |
Connecting Capacity Main Circuit | Flexible with Insulated Ferrule 1x 0.75 ... 4 mm² |
Connecting Capacity Main Circuit | Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm² |
Connecting Capacity Main Circuit | Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm² |
Connecting Capacity Main Circuit | Rigid 1/2x 1 ... 6 mm² |
Connecting Capacity Auxiliary Circuit | Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² |
Connecting Capacity Control Circuit | Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² |
Connecting Capacity Control Circuit | Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² |
Connecting Capacity Control Circuit | Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² |
Connecting Capacity Control Circuit | Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² |
Connecting Capacity Control Circuit | Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² |
Connecting Capacity Control Circuit | Rigid 1/2x 1 ... 2.5 mm² |
Wire Stripping Length | Control Circuit 10 mm |
Wire Stripping Length | Main Circuit 10 mm |
Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 |
Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20 |
Terminal Type | Screw Terminals |
Technical UL/CSA
Maximum Operating Voltage UL/CSA | Main Circuit 600 V |
General Use Rating UL/CSA | (600 V AC) 30 A |
Tightening Torque UL/CSA | Control Circuit 11 in·lb |
Tightening Torque UL/CSA | Main Circuit 13 in·lb |
Why Proax for ABB AFC16-04-00-84?
Proax is an authorized distributor of ABB AFC16-04-00-84 and one of ABB's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Alternate Names | AFC16040084 |
Pack Size | 1 |
Recommended