Proax

Currency
0 Items
proax logo
Cart
Phoenix ContactOfficial Distributor

By Phoenix Contact

SKU
MPN
PT 2,5-PE/L RD/L BU/L
Weight
0.032 kg
Series PT

PT 2,5-PE/L RD/L BU/L - Protective conductor terminal

Protective conductor terminal, number of connections: 8, number of positions: 4, connection method: Push-in connection, Protective conductor connection, Rated cross section: 2.5 mm2, cross section: 0.14 mm2 - 4 mm2, connection method: Push-in connection, Feed-through level, Rated cross section: 2.5 mm2, cross section: 0.14 mm2 - 4 mm2, mounting type: NS 35/7,5, NS 35/15, color: gray

Technical Specifications

General

NoteWhen establishing a connection on the open housing side of a feed-through modular terminal block of the same series and size, the block must be provided with a cover if the expected insulation voltage is >690 V.
NoteThe max. load current must not be exceeded by the total current of all connected conductors.

Product properties

Number of Positions4
Number of Connections8
Number of rows4

Insulation characteristics

Overvoltage categoryIII
Degree of pollution3

Electrical properties

Rated surge voltage6 kV

Connection data

Number of connections per level2
Nominal cross section2.5 mm²

Protective conductor connection

Stripping length8 mm ... 10 mm
Internal cylindrical gageA3
Internal cylindrical gageB3
Connection in acc. with standardIEC 60947-7-2
Conductor cross section rigid0.14 mm² ... 4 mm²
Cross section AWG26 ... 12 (converted acc. to IEC)
Conductor cross section flexible0.14 mm² ... 4 mm²
Conductor cross section, flexible [AWG]26 ... 12 (converted acc. to IEC)
Conductor cross-section flexible (ferrule without plastic sleeve)0.14 mm² ... 2.5 mm²
Flexible conductor cross section (ferrule with plastic sleeve)0.14 mm² ... 2.5 mm²
Nominal cross section2.5 mm²

Feed-through level

Stripping length8 mm ... 10 mm
Connection in acc. with standardIEC 60947-7-1
Conductor cross section rigid0.14 mm² ... 4 mm²
Cross section AWG26 ... 12 (converted acc. to IEC)
Conductor cross section flexible0.14 mm² ... 4 mm²
Conductor cross section, flexible [AWG]26 ... 12 (converted acc. to IEC)
Conductor cross-section flexible (ferrule without plastic sleeve)0.14 mm² ... 2.5 mm²
Flexible conductor cross section (ferrule with plastic sleeve)0.14 mm² ... 2.5 mm²
Nominal Current18 A
Maximum Load Current20 A (with 4 mm² conductor cross-section)
Nominal Voltage500 V
Nominal cross section2.5 mm²

Protective conductor connection Connection cross sections directly pluggable

Conductor cross section rigid0.34 mm² ... 4 mm²
Conductor cross section, rigid [AWG]20 ... 12 (converted acc. to IEC)
Conductor cross section flexible0.5 mm² ... 2.5 mm²
Conductor cross-section flexible (ferrule without plastic sleeve)0.5 mm² ... 2.5 mm²
Flexible conductor cross section (ferrule with plastic sleeve)0.5 mm² ... 2.5 mm²

Feed-through level Connection cross sections directly pluggable

Conductor cross section rigid0.34 mm² ... 4 mm²
Conductor cross section, rigid [AWG]20 ... 12 (converted acc. to IEC)
Conductor cross section flexible0.5 mm² ... 2.5 mm²
Conductor cross-section flexible (ferrule without plastic sleeve)0.5 mm² ... 2.5 mm²
Flexible conductor cross section (ferrule with plastic sleeve)0.5 mm² ... 2.5 mm²

Dimensions

Width5.2 mm
End cover width2.2 mm
Height142.4 mm
Depth on NS 35/7,568.6 mm
Depth on NS 35/1576.1 mm

Material specifications

Colorgray
Flammability rating according to UL 94V0
Insulating material groupI
Insulating materialPA
Static insulating material application in cold-60 °C
Relative insulation material temperature index (Elec., UL 746 B)130 °C
Fire protection for rail vehicles (DIN EN 45545-2) R22HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26HL 1 - HL 3
Surface flammability NFPA 130 (ASTM E 162)passed
Specific optical density of smoke NFPA 130 (ASTM E 662)passed
Smoke gas toxicity NFPA 130 (SMP 800C)passed

Mechanical data

Open side panelYes

Oscillation/broadband noise

SpecificationDIN EN 50155 (VDE 0115-200):2022-06
SpectrumService life test category 1, class B, body mounted
Frequencyf1 = 5 Hz to f2 = 150 Hz
ASD level0.964 (m/s²)²/Hz
Acceleration0.58g
Test duration per axis5 h
Test directionsX-, Y- and Z-axis
ResultTest passed

Shocks

SpecificationDIN EN 50155 (VDE 0115-200):2022-06
Pulse shapeHalf-sine
Acceleration5g
Shock duration30 ms
Number of shocks per direction3
Test directionsX-, Y- and Z-axis (pos. and neg.)
ResultTest passed

Ambient conditions

Ambient Temperature (Operation)-60 °C ... 110 °C (Operating temperature range incl. self-heating; for max. short-term operating temperature, see RTI Elec.)
Ambient temperature (storage/transport)-25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
Ambient temperature (assembly)-5 °C ... 70 °C
Ambient temperature (actuation)-5 °C ... 70 °C
Permissible humidity (operation)20 % ... 90 %
Permissible humidity (storage/transport)30 % ... 70 %

Standards and Regulations

Connection in acc. with standardIEC 60947-7-2
Connection in acc. with standardIEC 60947-7-1

Mounting

Mounting TypeNS 35/7,5
Mounting TypeNS 35/15

Why Proax for Phoenix Contact 1336370?

Proax is an authorized distributor of Phoenix Contact 1336370 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Pack Size1
Recommended

Not in stock

Request lead time or order—we'll ensure quick delivery

Phoenix Contact Availability