1019427
SKU
PHX1019427
MPN
SCC 15-F
Weight
0.028 kg
SCC 15-F - Shield connection clamp
Shield connection clamp, number of positions: 1, connection method: Spring-cage connection, mounting type: Mounting panel, color: black
- Convenient single-handed installation
- Shield connection clamps for cable diameters up to 20 mm
- Modern spring technology protects against vibrations
- Low transfer impedance due to large-surface shield connection
- High corrosion resistance
- Unique marking surface for cable designations
- As components, it is not possible to certify shield connections in accordance with the requirements of the directive and standards for electrical equipment in potentially explosive areas. As such, shield connection clamps can be used in the Ex area even without an appropriate approval or marking.
Technical Specifications
General
| Note | The shield connection clamps must not be used for strain relief of cables/conductors. |
| Note | Do not use for pretective conductor connection. |
Product properties
| Number of Positions | 1 |
Electrical properties
| Maximum power dissipation for nominal condition | 0 W |
Connection data
| Stripping length | 50 mm |
Dimensions
| Width | 19 mm |
| Height | 47.6 mm |
| Depth | 35 mm |
Material specifications
| Color | black |
| Flammability rating according to UL 94 | V0 |
| Insulating material group | CTI 600 |
| Insulating material | PA 6.6 |
| Static insulating material application in cold | -60 °C |
| Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) | 130 °C |
| Relative insulation material temperature index (Elec., UL 746 B) | 130 °C |
| Fire protection for rail vehicles (DIN EN 45545-2) R22 | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R23 | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R24 | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R26 | HL 1 - HL 3 |
| Calorimetric heat release NFPA 130 (ASTM E 1354) | 28 MJ/kg |
| Surface flammability NFPA 130 (ASTM E 162) | passed |
| Specific optical density of smoke NFPA 130 (ASTM E 662) | passed |
| Smoke gas toxicity NFPA 130 (SMP 800C) | passed |
Cable/line
| External Cable Diameter | 8 mm ... 15 mm |
Mechanical strength
| Result | Test passed |
Needle-flame test
| Time of exposure | 30 s |
| Result | Test passed |
Oscillation/broadband noise
| Specification | DIN EN 50155 (VDE 0115-200):2018-05 |
| Spectrum | Service life test category 2, bogie-mounted |
| Frequency | f1 = 5 Hz to f2 = 250 Hz |
| ASD level | 6.12 (m/s²)²/Hz |
| Acceleration | 3.12g |
| Test duration per axis | 5 h |
| Test directions | X-, Y- and Z-axis |
| Result | Test passed |
Shocks
| Specification | DIN EN 50155 (VDE 0115-200):2018-05 |
| Pulse shape | Half-sine |
| Acceleration | 30g |
| Shock duration | 18 ms |
| Number of shocks per direction | 3 |
| Test directions | X-, Y- and Z-axis (pos. and neg.) |
| Result | Test passed |
Ambient conditions
| Ambient temperature (storage/transport) | -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C) |
| Ambient temperature (assembly) | -5 °C ... 70 °C |
| Ambient temperature (actuation) | -5 °C ... 70 °C |
| Permissible humidity (storage/transport) | 30 % ... 70 % |
Mounting
| Mounting Type | Mounting panel |
Why Proax for Phoenix Contact 1019427?
Proax is an authorized distributor of Phoenix Contact 1019427 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
| Pack Size | 20 |