Proax

Currency
0 Items
proax logo
Cart
Phoenix ContactOfficial Distributor

By Phoenix Contact

SKU
MPN
SAC-5P-M12FS/.../...
Series SAC-5P

SAC-5P-M12FS/.../... - Sensor/actuator cable

Sensor/actuator cable, 5-position, free cable end, on Socket straight M12, coding: A, cable length: Free input (0.2 ... 40.0 m)

  • Easy and safe: 100 % electrically tested plug-in components
Technical Specifications

Product properties

ApplicationStandard
ApplicationRobots and drag chains
Number of Positions5
No. of cable outlets1
Shieldedno
CodingA

Insulation characteristics

Overvoltage categoryII
Degree of pollution3

Material specifications

Flammability rating according to UL 94HB
Seal materialNBR
Material of grip bodyTPU, hardly inflammable, self-extinguishing
Contact MaterialCuSn
Contact surface materialNi/Au
Contact carrier materialTPU GF
Material for screw connectionZinc die-cast, nickel-plated

Electrical properties

Insulation resistance≥ 100 MΩ
Nominal voltage UN48 V AC
Nominal voltage UN60 V DC
Nominal current IN4 A

Mechanical data

Insertion/withdrawal cycles≥ 100

Signaling

Status displayNo
Status display presentNo

Conductor connection

Tightening torque0.4 Nm (M12 connector)

Connection 1

Typefree cable end

Connection 2

TypeSocket straight M12
Number of Positions5
Coding typeA

Cable/line

Cable LengthFree input (0.2 ... 40.0 m)

PUR halogen-free black [PUR]

Cable weight33 kg/km
UL AWM style20549
Number of Positions5
Shieldedno
Cable TypePUR halogen-free black [PUR]
Cable TypePUR halogen-free black PUR
Conductor structure signal line42x 0.10 mm
AWG Signal Line22
Conductor Cross Section5x 0.34 mm² (Signal line)
Wire diameter incl. insulation1.27 mm 0.05 mm (Signal line)
External Cable Diameter4.55 mm ±0.15 mm
Outer sheath, materialPUR
External sheath, colorblack-gray RAL 7021
Conductor materialBare Cu litz wires
Material wire insulationPP
Single wire, colorbrown, white, blue, black, green-yellow
Thickness, insulationapprox. 0.50 mm
Max. conductor resistancemax. 58 Ω/km (at 20 °C)
Insulation resistance≥ 16 GΩ*km (at 20 °C)
Nominal voltage, cable300 V
Test voltage3000 V
Smallest bending radius, fixed installation23 mm
Smallest bending radius, movable installation46 mm
Max. bending cycles4000000
Halogen-freein accordance with DIN VDE 0472 part 815
Flame resistancein accordance with UL 758/1581 FT2
Flame resistanceDIN EN 60332-2-2 (20 s)
Resistance to Oilin accordance with DIN EN 60811-2-1
Other resistanceHighly resistant to acids, alkaline solutions and solvents
Other resistancehydrolysis and microbe resistant
Other resistanceResistant to salt water
Other resistancepartly UV-resistant (in accordance with DIN EN ISO 4892-2-A)
Special PropertiesFlexible cable conduit capable
Special PropertiesSilicone-free
Special PropertiesFree of substances which would hinder coating with paint or varnish
Special Propertiesflexible
Ambient Temperature (Operation)-40 °C ... 80 °C (cable, fixed installation)
Ambient Temperature (Operation)-25 °C ... 80 °C (Cable, flexible installation)

PUR halogen-free gray [280]

Shieldedno
Cable TypePUR halogen-free gray [280]
Cable TypePUR halogen-free gray 280
External Cable Diameter4.60 mm

PUR, black, 5th conductor gray [115]

Cable weight35 kg/km
UL AWM style20549 / 10493 (80°C/300 V)
Number of Positions5
Shieldedno
Cable TypePUR, black, 5th conductor gray [115]
Cable TypePUR, black, 5th conductor gray 115
Conductor structure signal line42x 0.10 mm
AWG Signal Line22
Conductor Cross Section5x 0.34 mm²
Wire diameter incl. insulation1.27 mm ±0.02 mm
External Cable Diameter5.00 mm ±0.15 mm
Outer sheath, materialPUR
External sheath, colorblack-gray RAL 7021
Conductor materialBare Cu litz wires
Material, fillerPP
Material wire insulationPP
Single wire, colorbrown, white, blue, black, gray
Thickness, insulation≥ 0.21 mm
Thickness, outer sheathapprox. 0.70 mm
Overall twist5 cores, twisted
Max. conductor resistance≤ 58 Ω/km
Nominal voltage, cable≤ 300 V
Test voltage≥ 3000 V
Minimum bending radius, fixed installation5 x D
Minimum bending radius, flexible installation10 x D
Smallest bending radius, fixed installation25 mm
Smallest bending radius, movable installation50 mm
Max. bending cycles4000000
Halogen-freein accordance with DIN VDE 0472 part 815
Flame resistancein accordance with DIN UL-Style 20549
Flame resistancein accordance with UL 758/1581 FT2
Resistance to Oilin accordance with DIN EN 60811-2-1
Other resistancepartly UV-resistant (in accordance with DIN EN ISO 4892-2-A)
Other resistancehydrolysis and microbe resistant
Other resistanceResistant to salt water
Other resistanceLow adhesion
Other resistanceabrasion-resistant
Special PropertiesFlexible cable conduit capable
Special PropertiesSilicone-free
Special PropertiesFree of substances which would hinder coating with paint or varnish
Special Propertiesflexible
Ambient Temperature (Operation)-40 °C ... 80 °C (cable, fixed installation)
Ambient Temperature (Operation)-25 °C ... 80 °C (Cable, flexible installation)

PUR irradiated halogen-free orange [150]

Number of Positions5
Shieldedno
Cable TypePUR irradiated halogen-free orange [150]
Cable TypePUR irradiated halogen-free orange 150
Conductor structure signal line42x 0.10 mm
AWG Signal Line22
Conductor structure, voltage supply24x 0.15 mm
AWG Power Supply20
Conductor Cross Section4x 0.34 mm² (Signal line)
Conductor Cross Section1x 0.5 mm² (PE connection)
External Cable Diameter5.20 mm ±0.2 mm
Outer sheath, materialPUR
External sheath, colororange RAL 2003
Conductor materialBare Cu litz wires
Material wire insulationPE
Single wire, colorbrown, white, blue, black, green-yellow
Overall twist5 cores, twisted
Max. conductor resistance≤ 57.5 Ω/km (with 0.34 mm² conductor cross section)
Max. conductor resistance≤ 39 Ω/km (with 0.5 mm² conductor cross section)
Nominal voltage, cable250 V (AC)
Test voltage2000 V (50 Hz, 5 minutes)
Smallest bending radius, fixed installation20 mm
Smallest bending radius, movable installation30 mm
Max. bending cycles5000000
Halogen-freeThe cable is halogen-free
Flame resistanceDIN VDE 0472 part 804, test type B
Other resistancehydrolysis and microbe resistant
Other resistanceUV resistant
Other resistanceResistant to welding splashes
Special PropertiesSilicone-free
Special PropertiesIrradiated
Ambient Temperature (Operation)-50 °C ... 105 °C (cable, fixed installation)
Ambient Temperature (Operation)-40 °C ... 105 °C (Cable, flexible installation)

PUR halogen-free orange [180]

Cable weight36 kg/km
UL AWM style20549
Number of Positions5
Shieldedno
Cable TypePUR halogen-free orange [180]
Cable TypePUR halogen-free orange 180
Conductor structure signal line42x 0.10 mm
AWG Signal Line22
Conductor structure, voltage supply28x 0.15 mm
AWG Power Supply20
Conductor Cross Section4x 0.34 mm² (Signal line)
Conductor Cross Section1x 0.5 mm² (PE connection)
Wire diameter incl. insulation1.27 mm ±0.02 mm (Signal line)
Wire diameter incl. insulation1.46 mm ±0.02 mm (PE connection)
External Cable Diameter5.00 mm ±0.15 mm
Outer sheath, materialPUR
External sheath, colororange RAL 2003
Conductor materialBare Cu litz wires
Material wire insulationPP
Single wire, colorbrown, white, blue, black, green-yellow
Thickness, insulation≥ 0.21 mm (Signal line)
Thickness, insulation≥ 0.21 mm (PE connection)
Thickness, insulationapprox. 0.65 mm (Outer cable sheath)
Overall twist5 wires around filler to the core
Max. conductor resistance≤ 58 Ω/km (Signal line)
Max. conductor resistance≤ 39 Ω/km (PE connection)
Insulation resistance≥ 10 GΩ*km (at 20 °C)
Nominal voltage, cable≤ 300 V
Test voltage≥ 3000 V
Halogen-freein accordance with DIN VDE 0472 part 815
Flame resistancein accordance with DIN UL-Style 20549
Ambient Temperature (Operation)-25 °C ... 80 °C (Cable)

PUR POWER 0.75 mm² black [186]

Cable weight67 kg/km
Number of Positions5
Shieldedno
Cable TypePUR POWER 0.75 mm² black [186]
Cable TypePUR POWER 0.75 mm² black 186
Conductor structure signal line42x 0.15 mm
AWG Signal Line18
Conductor Cross Section5x 0.75 mm² (power line)
Wire diameter incl. insulation1.7 mm ±0.05 mm
External Cable Diameter6.30 mm ±0.2 mm
Outer sheath, materialPUR
External sheath, colorblack-gray RAL 7021
Conductor materialBare Cu litz wires
Material wire insulationPVC
Single wire, colorbrown, white, blue, black, gray
Thickness, insulation≥ 0.23 mm (Core insulation)
Thickness, insulation≥ 0.76 mm (Outer cable sheath)
Overall twist5 wires around filler to the core
Max. conductor resistancemax. 26 Ω/km (at 20 °C)
Insulation resistance≥ 1 MΩ*km (at 20 °C)
Nominal voltage, cable≤ 300 V
Test voltage≥ 3000 V
Smallest bending radius, movable installation63 mm
Max. bending cycles2000000
Flame resistancein accordance with DIN UL-Style 20549
Resistance to Oilin accordance with DIN EN 60811-2-1
Ambient Temperature (Operation)-25 °C ... 80 °C (cable, fixed installation)
Ambient Temperature (Operation)-5 °C ... 80 °C (Cable, flexible installation)

PUR halogen-free yellow [240]

Cable weight35 kg/km
UL AWM style20549 / 10493 (80°C/300 V)
Number of Positions5
Shieldedno
Cable TypePUR halogen-free yellow [240]
Cable TypePUR halogen-free yellow 240
Conductor structure signal line42x 0.10 mm
AWG Signal Line22
Conductor Cross Section5x 0.34 mm²
Wire diameter incl. insulation1.27 mm ±0.02 mm
External Cable Diameter5.00 mm ±0.15 mm
Outer sheath, materialPUR
External sheath, coloryellow
Conductor materialBare Cu litz wires
Material wire insulationPP
Single wire, colorbrown, white, blue, black, green-yellow
Thickness, insulation≥ 0.21 mm
Thickness, outer sheathapprox. 0.70 mm
Overall twist5 wires around filler to the core
Length of twist, overall twist55 mm
Max. conductor resistance≤ 58 Ω/km (at 20 °C)
Nominal voltage, cable≤ 300 V
Test voltage≥ 3000 V
Minimum bending radius, fixed installation5 x D
Minimum bending radius, flexible installation10 x D
Smallest bending radius, fixed installation25 mm
Smallest bending radius, movable installation50 mm
Max. bending cycles4000000
Halogen-freein accordance with DIN VDE 0472 part 815
Flame resistancein accordance with DIN UL-Style 20549
Flame resistancein accordance with UL 758/1581 FT2
Resistance to Oilin accordance with DIN EN 60811-2-1
Other resistancehydrolysis and microbe resistant
Other resistanceResistant to salt water
Ambient Temperature (Operation)-40 °C ... 80 °C (cable, fixed installation)
Ambient Temperature (Operation)-25 °C ... 80 °C (Cable, flexible installation)

PUR halogen-free gray [280]

Number of Positions5
Shieldedno
Cable TypePUR halogen-free gray [280]
Cable TypePUR halogen-free gray 280
Conductor structure signal line42x 0.10 mm
AWG Signal Line22
Conductor structure, voltage supply28x 0.15 mm
AWG Power Supply20
Conductor Cross Section0.34 mm²
Wire diameter incl. insulation1.55 mm (Signal line)
Wire diameter incl. insulation1.65 mm (Protective conductor)
External Cable Diameter5.20 mm
External Cable Diameter5.20 mm
Outer sheath, materialPUR
External sheath, colorgray RAL 7001
Conductor materialBare Cu litz wires
Material, fillerFiberglass
Material wire insulationTPE
Single wire, colorbrown, white, blue, black, green-yellow
Thickness, insulation0.39 mm (Signal line)
Thickness, insulation0.37 mm (Protective conductor)
Thickness, insulation0.65 mm (Outer cable sheath)
Overall twist5 wires around filler to the core
Ambient Temperature (Operation)-40 °C ... 80 °C (cable, fixed installation)
Ambient Temperature (Operation)-5 °C ... 80 °C (Cable, flexible installation)

PVC black [PVC]

Cable weight51 kg/km
UL AWM style2464 / 1729 (80°C/300 V)
Number of Positions5
Shieldedno
Cable TypePVC black [PVC]
Cable TypePVC black PVC
Conductor structure signal line19x 0.15 mm
AWG Signal Line22
Conductor Cross Section5x 0.34 mm² (Signal line)
Wire diameter incl. insulation1.26 mm ±0.05 mm
External Cable Diameter5.00 mm ±0.15 mm
Outer sheath, materialPVC
External sheath, colorblack RAL 9005
Conductor materialBare Cu litz wires
Material wire insulationPVC
Single wire, colorbrown, white, blue, black, green-yellow
Thickness, insulation≥ 0.23 mm (Core insulation)
Thickness, outer sheath≥ 0.76 mm
Overall twist5 wires around filler to the core
Max. conductor resistancemax. 57 Ω/km (at 20 °C)
Insulation resistance≥ 200 MΩ*km (at 20 °C)
Nominal voltage, cable≤ 300 V
Test voltage≥ 3000 V
Minimum bending radius, fixed installation5 x D
Minimum bending radius, flexible installation10 x D
Smallest bending radius, fixed installation25 mm
Smallest bending radius, movable installation50 mm
Flame resistanceAs per UL-Style 2464
Resistance to Oilin accordance with DIN EN 60811-2-1
Ambient Temperature (Operation)-25 °C ... 80 °C (cable, fixed installation)
Ambient Temperature (Operation)-10 °C ... 80 °C (Cable, flexible installation)

PVC gray [500]

Cable weight51 kg/km
UL AWM style2464 / 1729 (80°C/300 V)
Number of Positions5
Shieldedno
Cable TypePVC gray [500]
Cable TypePVC gray 500
Conductor structure signal line19x 0.15 mm
AWG Signal Line22
Conductor Cross Section5x 0.34 mm² (Signal line)
Wire diameter incl. insulation1.26 mm ±0.05 mm
External Cable Diameter5.00 mm ±0.15 mm
Outer sheath, materialPVC
External sheath, colorgray RAL 7001
Conductor materialBare Cu litz wires
Material wire insulationPVC
Single wire, colorbrown, white, blue, black, green-yellow
Thickness, insulation≥ 0.23 mm (Core insulation)
Thickness, outer sheath≥ 0.76 mm
Overall twist5 wires around filler to the core
Max. conductor resistancemax. 57 Ω/km (at 20 °C)
Insulation resistance≥ 200 MΩ*km (at 20 °C)
Nominal voltage, cable≤ 300 V
Test voltage≥ 3000 V
Minimum bending radius, fixed installation5 x D
Minimum bending radius, flexible installation10 x D
Smallest bending radius, fixed installation25 mm
Smallest bending radius, movable installation50 mm
Flame resistanceAs per UL-Style 2464
Ambient Temperature (Operation)-40 °C ... 80 °C (cable, fixed installation)
Ambient Temperature (Operation)-25 °C ... 80 °C (Cable, flexible installation)

PVC black 5th conductor gray [515]

Cable weight52 kg/km
UL AWM style2464 / 1729 (80°C/300 V)
Number of Positions5
Shieldedno
Cable TypePVC black 5th conductor gray [515]
Cable TypePVC black 5th conductor gray 515
Conductor structure signal line42x 0.10 mm
AWG Signal Line22
Conductor Cross Section5x 0.34 mm² (Signal line)
Wire diameter incl. insulation1.45 mm ±0.02 mm
External Cable Diameter5.90 mm ±0.15 mm
Outer sheath, materialPVC
External sheath, colorblack RAL 9005
Conductor materialBare Cu litz wires
Material, fillerPP yarn
Material wire insulationPVC
Single wire, colorbrown, white, blue, black, gray
Thickness, insulation≥ 0.23 mm (Core insulation)
Thickness, insulation≥ 0.76 mm (Outer cable sheath)
Overall twist5 wires around filler to the core
Length of twist, overall twist60 mm
Max. conductor resistance≤ 58 Ω/km (at 20 °C)
Insulation resistance≥ 100 MΩ*km (at 20 °C)
Nominal voltage, cable≤ 300 V AC
Test voltage≥ 3000 V AC
Minimum bending radius, fixed installation5 x D
Minimum bending radius, flexible installation10 x D
Smallest bending radius, fixed installation30 mm
Smallest bending radius, movable installation59 mm
Flame resistanceAccording to UL 758/1581 (Cable Flame)
Flame resistanceaccording to UL 758/1581 FT1
Flame resistanceAccording to DIN EN 60332-1-2 (60 s)
Resistance to Oilaccording to DIN EN 60811-2-1, 168 h at 60 °C
Ambient Temperature (Operation)-40 °C ... 80 °C (cable, fixed installation)
Ambient Temperature (Operation)-25 °C ... 80 °C (Cable, flexible installation)

PVC gray 5th conductor gray [520]

Cable weight54 kg/km
Number of Positions5
Shieldedno
Cable TypePVC gray 5th conductor gray [520]
Cable TypePVC gray 5th conductor gray 520
Conductor structure signal line42x 0.10 mm
AWG Signal Line22
Conductor Cross Section0.34 mm²
Wire diameter incl. insulation1.45 mm ±0.02 mm
External Cable Diameter5.90 mm ±0.15 mm
Outer sheath, materialPVC
External sheath, colorgray RAL 7001
Conductor materialBare Cu litz wires
Material, fillerPVC
Material wire insulationPVC
Single wire, colorbrown, white, blue, black, gray
Thickness, insulation≥ 0.23 mm (Core insulation)
Thickness, insulation≥ 0.76 mm (Outer cable sheath)
Overall twist5 wires around filler to the core
Length of twist, overall twist55 mm
Max. conductor resistancemax. 58 Ω/km (at 20 °C)
Insulation resistance≥ 1 GΩ*km (at 20 °C)
Nominal voltage, cable≤ 300 V
Test voltage≥ 3000 V
Flame resistanceAs per UL-Style 2464
Ambient Temperature (Operation)-25 °C ... 80 °C (cable, fixed installation)
Ambient Temperature (Operation)-5 °C ... 80 °C (Cable, flexible installation)

PVC yellow [540]

Number of Positions5
Shieldedno
Cable TypePVC yellow [540]
Cable TypePVC yellow 540
Conductor structure signal line43x 0.10 mm
AWG Signal Line22
Conductor Cross Section0.34 mm²
Wire diameter incl. insulation1.45 mm ±0.02 mm
External Cable Diameter5.90 mm ±0.15 mm
Outer sheath, materialPVC
External sheath, coloryellow
Conductor materialBare Cu litz wires
Material, fillerPVC
Material wire insulationPVC
Single wire, colorbrown, white, blue, black, green-yellow
Thickness, insulationapprox. 0.23 mm (Core insulation)
Thickness, insulationapprox. 0.76 mm (Outer cable sheath)
Overall twist5 wires around filler to the core
Length of twist, overall twist70 mm
Max. conductor resistancemax. 58 Ω/km (at 20 °C)
Insulation resistance≥ 1 MΩ*km (at 20 °C)
Nominal voltage, cable≤ 300 V (AC)
Test voltage3000 V
Smallest bending radius, fixed installation29.5 mm
Smallest bending radius, movable installation59 mm
Flame resistanceAs per UL-Style 2464
Flame resistanceaccording to UL 758/1581 FT1
Resistance to Oilin accordance with DIN EN 60811-2-1
Ambient Temperature (Operation)-40 °C ... 80 °C (cable, fixed installation)
Ambient Temperature (Operation)-25 °C ... 80 °C (Cable, flexible installation)

PVC yellow 105 °C [542]

Cable weight50 kg/km
Number of Positions5
Shieldedno
Cable TypePVC yellow 105 °C [542]
Cable TypePVC yellow 105 °C 542
Conductor structure signal line42x 0.10 mm
AWG Signal Line22
Conductor Cross Section0.34 mm²
Wire diameter incl. insulation1.55 mm ±0.05 mm
External Cable Diameter5.90 mm ±0.2 mm
Outer sheath, materialPVC
External sheath, coloryellow
Conductor materialBare Cu litz wires
Material wire insulationPVC
Single wire, colorbrown, white, blue, black, gray
Thickness, insulation≥ 0.38 mm (Core insulation)
Thickness, insulation≥ 0.76 mm (Outer cable sheath)
Overall twist5 wires around filler to the core
Max. conductor resistancemax. 58 Ω/km (at 20 °C)
Insulation resistance≥ 100 MΩ*km (at 20 °C)
Nominal voltage, cable≤ 300 V
Test voltage≥ 3000 V
Flame resistancein accordance with UL-Style 2517
Ambient Temperature (Operation)-25 °C ... 105 °C (cable, fixed installation)
Ambient Temperature (Operation)-25 °C ... 80 °C (Cable, flexible installation)

Gray, highly flexible PUR [800]

NoteDue to the extremely robust outer sheath, this cable should only be stripped in 5 cm increments.
Cable weight38 kg/km
UL AWM style20549
Number of Positions5
Shieldedno
Cable TypeGray, highly flexible PUR [800]
Cable TypeGray, highly flexible PUR 800
Conductor structure signal line42x 0.10 mm
AWG Signal Line22
Conductor Cross Section5x 0.34 mm² (Signal line)
Wire diameter incl. insulation1.3 mm ±0.05 mm (Signal line)
External Cable Diameter5.10 mm ±0.2 mm
Outer sheath, materialPUR
External sheath, colorgray RAL 7001
Conductor materialBare Cu litz wires
Material, fillerPE
Material wire insulationPP
Single wire, colorblack, brown,blue, white, gray
Overall twist5 wires around filler to the core
Max. conductor resistanceapprox. 53 Ω/km
Insulation resistance≥ 20 MΩ*km
Nominal voltage, cable300 V
Test voltage2000 V
Minimum bending radius, fixed installation4 x D
Minimum bending radius, flexible installation7.5 x D
Smallest bending radius, fixed installation21 mm
Smallest bending radius, movable installation39 mm
Max. bending cycles10000000
Max. bending cycles15000000
Torsion force± 360 °/m
Torsion cycles1000000
Torsional frequency1000000
Halogen-freein accordance with DIN VDE 0472 part 815
Flame resistancein accordance with UL 758/1581 FT2
Resistance to Oilin accordance with DIN EN 60811-2-1
Other resistanceHighly resistant to acids, alkaline solutions and solvents
Other resistanceSilicone-free
Special PropertiesCable jacket is welding spark-resistant, recyclable, matt, low-adhesion, abrasion-resistant, flame-retardant, and self-extinguishing
Special PropertiesFree from silicone and cadmium
Special PropertiesFree of substances which would hinder coating with paint or varnish
Ambient Temperature (Operation)-40 °C ... 80 °C (cable, fixed installation)
Ambient Temperature (Operation)-25 °C ... 80 °C (Cable, flexible installation)

Ambient conditions

Degree of ProtectionIP65
Degree of ProtectionIP67
Degree of ProtectionIP68
Ambient Temperature (Operation)-25 °C ... 90 °C (Plug / socket)

Standards and Regulations

Standard designationM12 connector
Standards/specificationsIEC 61076-2-101

Why Proax for Phoenix Contact 1697111?

Proax is an authorized distributor of Phoenix Contact 1697111 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Pack Size1
Recommended

Not in stock

Request lead time or order—we'll ensure quick delivery

Phoenix Contact Availability