Official Distributor
SKU
Weight
3.042 kg
Series VIP-PA-PWR
VIP-PA-PWR/36XOE/ 6,0M/1756 - Adaptateur frontal
Adaptateur frontal VIP VARIOFACE avec câble rond blindé pré-équipé pour ControlLogix® 1756 E/S, 1 x 36 conducteurs individuels peuvent être raccordés
- Les différents modules E/S sont verrouillés sur l'automate pour garantir la solidité de la connexion
- Un levier intégré facilite le retrait de la carte E/S
- Étiquette de repérage montable
- Liaison 1:1
- Extrémité non terminée d'un côté
- Repérage des fils : 1, 2, 3, 4, ...
- Équiper les fils d'embouts
- Raccordement de blindage : type UL AWN, style 1007, câble 18 AWG (0,82 mm²), noir, longueur : 0,5 m
Technical Specifications
Insulation characteristics
Overvoltage category | II |
Pollution degree | 2 |
Electrical properties
Max. permissible operating voltage | 250 V AC/DC |
Max. permissible current | 3 A (per single wire at 60°C) |
Max. permissible current | 4 A (per single wire at 40°C) |
Supported controller ALLEN-BRADLEY ControlLogix
Suitable I/O card | 1756-IB16D |
Suitable I/O card | 1756-IB16I |
Suitable I/O card | 1756-IB32 |
Suitable I/O card | 1756-IF16 |
Suitable I/O card | 1756-IF8 |
Suitable I/O card | 1756-IF8I |
Suitable I/O card | 1756-IRT8I |
Suitable I/O card | 1756-OB16D |
Suitable I/O card | 1756-OB16I |
Suitable I/O card | 1756-OB32 |
Suitable I/O card | 1756-HSC |
Suitable I/O card | 1756-IA16I |
Suitable I/O card | 1756-IA32 |
Suitable I/O card | 1756-IB16IF |
Suitable I/O card | 1756-IB16ISOE |
Suitable I/O card | 1756-IF16H |
Suitable I/O card | 1756-IF4FXOF2F |
Suitable I/O card | 1756-IF8H |
Suitable I/O card | 1756-IF8IH |
Suitable I/O card | 1756-IH16I |
Suitable I/O card | 1756-IH16ISOE |
Suitable I/O card | 1756-IM16I |
Suitable I/O card | 1756-IR12 |
Suitable I/O card | 1756-IT16 |
Suitable I/O card | 1756-IV32 |
Suitable I/O card | 1756-LSC8XIB8I |
Suitable I/O card | 1756-OA16I |
Suitable I/O card | 1756-OB16IEF |
Suitable I/O card | 1756-OB16IEFS |
Suitable I/O card | 1756-OB16IS |
Suitable I/O card | 1756-OB8EI |
Suitable I/O card | 1756-OF8I |
Suitable I/O card | 1756-OF8IH |
Suitable I/O card | 1756-OH8I |
Suitable I/O card | 1756-OV32E |
Suitable I/O card | 1756-OW16I |
Suitable I/O card | 1756-OX8I |
Controller level
Connection Method | Plug-in connection |
Note | Can be plugged onto 36-pos. I/O modules |
Field level
Connection Method | Single wires |
Number of Connections | 36 |
Number of Positions | 1 |
Note | The wires are marked and fitted with ferrules |
Cable
Length | 6 m |
Cable/line
Number of Positions | 36 |
Shielded | yes |
Conductor type | Assembled shielded round cable |
AWG Signal Line | 18 |
Conductor Cross Section | 36x 0.82 mm² |
Wire diameter incl. insulation | 1.7 mm ±0.0254 |
External Cable Diameter | 15.88 mm ±0.3 mm |
Outer sheath, material | PVC |
External sheath, color | gray |
Conductor material | Tin-plated Cu litz wires |
Cable resistance | ≤ 40 Ω/km (20 °C) |
Insulation resistance | ≥ 20 MΩ*km (20 °C) |
Smallest bending radius, fixed installation | 109.5 mm |
Smallest bending radius, movable installation | 156.2 mm |
Halogen-free | no |
Flame resistance | UL VW-1 |
Flame resistance | CSA FT-1 |
1X1.0 [PVC]
Cable Type | 1X1.0 [PVC] |
ControlLogix plug (1) | () = black |
ControlLogix plug (2) | () = brown |
ControlLogix plug (3) | () = red |
ControlLogix plug (4) | () = orange |
ControlLogix plug (5) | () = yellow |
ControlLogix plug (6) | () = green |
ControlLogix plug (7) | () = blue |
ControlLogix plug (8) | () = violet |
ControlLogix plug (9) | () = gray |
ControlLogix plug (10) | () = white |
ControlLogix plug (11) | () = white-black |
ControlLogix plug (12) | () = white-brown |
ControlLogix plug (13) | () = white-red |
ControlLogix plug (14) | () = white-orange |
ControlLogix plug (15) | () = white-yellow |
ControlLogix plug (16) | () = white-green |
ControlLogix plug (17) | () = white-blue |
ControlLogix plug (18) | () = white-violet |
ControlLogix plug (19) | () = white-gray |
ControlLogix plug (20) | () = brown-black |
ControlLogix plug (21) | () = brown-red |
ControlLogix plug (22) | () = brown-orange |
ControlLogix plug (23) | () = brown-yellow |
ControlLogix plug (24) | () = brown-green |
ControlLogix plug (25) | () = brown-blue |
ControlLogix plug (26) | () = brown-violet |
ControlLogix plug (27) | () = brown-gray |
ControlLogix plug (28) | () = brown-white |
ControlLogix plug (29) | () = green-black |
ControlLogix plug (30) | () = green-brown |
ControlLogix plug (31) | () = green-red |
ControlLogix plug (32) | () = green-orange |
ControlLogix plug (33) | () = green-blue |
ControlLogix plug (34) | () = green-violet |
ControlLogix plug (35) | () = green-gray |
ControlLogix plug (36) | () = green-white |
Cable Type | Front adapter with cable and 36 open cable ends |
Ambient conditions
Degree of protection (IP20) | IP20 |
Ambient Temperature (Operation) | 0 °C ... 60 °C |
Ambient temperature (storage/transport) | -20 °C ... 70 °C |
Altitude | < 2000 m |
UL data
Max. permissible relative humidity (operation) | < 95 % |
Standards and Regulations
Standards/regulations | UL 61010-2-201 |
Notes
Notes on operation | For proper use, the specifications of the installation directive (see Downloads) must be observed. For applications or use with third-party products, the specifications, and the safety and warning instructions of the respective third-party manufacturer must also be met. |
Why Proax for Phoenix Contact 2908862?
Proax is an authorized distributor of Phoenix Contact 2908862 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size | 1 |
Recommended
- VIP-Power Cabling, adaptateur frontal avec câble rond blindé pré-équipé pour la connexion de tous les modules courant E/S à 36 pôles ControlLogix® 1756. 1 x 36 conducteurs individuels (munis chacun d'un embout et marqués) peuvent être raccordés (raccordement sur le terrain, par exemple via 36 blocs de jonction).
- VIP-Power Cabling, adaptateur frontal avec câble rond blindé pré-équipé pour la connexion de tous les modules courant E/S à 20 pôles ControlLogix® 1756. 1 x 20 conducteurs individuels (munis chacun d'un embout et marqués) peuvent être raccordés (raccordement sur le terrain, par exemple via 20 blocs de jonction).