Proax

Currency
0 Items
proax logo
Cart
ABBOfficial Distributor

By ABB

SKU
MPN
1SBN020314R1000
TEF5-OFF is a frontal electronic timer used to realize the timing function and allow a compact solution in the cabinet compared to separate timers. TEF5 electronic timers are front-mounted and locked on UA16..UA75, AX contactors or NX contactor relays. A mechanical indicator allows to show the state of the contactor. TEF5 electronic timers are supplied by direct wiring to the coil terminals A1 - A2 of the contactor or contactor relay. A varistor is integrated on the timer to offer a built-in protection against surges in the contactor coil. The TEF45 is available for a wide control voltage range 24...240 V AC/DC. TEF5 allow time-delayed functions up to 100 s in 3 distinct time ranges, independently of the control system. The time delay ranges are selected by a switch and the time delay can be adjusted by means of a rotary switch. The timing function of TEF5-OFF is activated by opening the device on which the timer is mounted. The OFF-delay version operates without additional control supply.
Technical Specifications

Dimensions

Product Net Width44 mm
Product Net Depth / Length62.5 mm
Product Net Height40.5 mm
Product Net Weight0.065 kg

Technical

Number of Auxiliary Contacts NO1
Number of Auxiliary Contacts NC1
StandardsIEC/EN 60947-5-1, UL 508, CSA C22-2 No. 14-18
Rated Operational VoltageAuxiliary Circuit 240 V AC
Rated Frequency (f)Auxiliary Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)acc. to IEC 60947-5-1, Θ = 40 °C 5 A
Rated Operational Current AC-15 (Ie)(24 / 127 V) 3 A
Rated Operational Current AC-15 (Ie)(220 / 240 V) 1.5 A
Rated Short-time Withstand Current Low Voltage (Icw)for 0.1 s 8 A
Rated Short-time Withstand Current Low Voltage (Icw)for 1 s 8 A
Maximum Electrical Switching Frequency(AC-15) 1200 cycles per hour
Maximum Electrical Switching Frequency(DC-13) 900 cycles per hour
Rated Operational Current DC-13 (Ie)(24 V) 1 A / 24 W
Rated Insulation Voltage (Ui)acc. to IEC 60947-5-1 400 V
Rated Insulation Voltage (Ui)acc. to UL/CSA 300 V
Rated Impulse Withstand Voltage (Uimp)4 kV
Maximum Mechanical Switching Frequency1800 cycles per hour
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20
Terminal TypeScrew Terminals
Suitable forGA75
Suitable forGAE75
Suitable forUA16
Suitable forUA26
Suitable forUA30
Suitable forUA50
Suitable forUA63
Suitable forUA75
Suitable forAX06
Suitable forAX09
Suitable forAX12
Suitable forAX18
Suitable forAX25
Suitable forAX32
Suitable forAX40
Suitable forAX50
Suitable forAX65
Suitable forAX80

Technical UL/CSA

Tightening Torque UL/CSAAuxiliary Circuit 9 in·lb

Why Proax for ABB TEF5-OFF?

Proax is an authorized distributor of ABB TEF5-OFF and one of ABB's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Alternate NamesTEF5OFF
Pack Size1
Recommended