Cooling Fan
MDA1225-24
SKU
ORIMDA122524
Series MD Series DC Axial Fans
4.69 in. (119 mm) DC Axial Fan with Alarm
The MD Series A Type features a built-in alarm circuit that the host controller can recognize if the fan speed drops. This is important for noticing quick drops in the cooling capacity of the fan caused by a service life of the fan or by the ingress of a foreign objects.- Alarm Type
Documents
Technical Specifications
Fan Type | Axial Fan |
Frame Size | 4.69 in |
Thickness | 1 in. |
Power Supply | 24 VDC |
Current | 0.34 |
Type | A Type (with Alarm) |
Function | Low Speed Alarm - Electronic |
Connection Type | Lead Wire |
Speed (r/min) | 3000 |
Max. Air Flow | 95.3 CFM |
Max. Static Pressure | 0.281 inH2O |
Noise Level | 46 dB (A) |
RoHS Compliant | These products do not contain substances that exceed the regulation values in the RoHS Directive. |
Safety Standards | UL |
CE Marking | EMC Directives |
Insulation resistance | 10 MΩ or more when 250 VDC is applied between the windings and the frame after continuous operation under normal ambient temperature and humidity. |
Dielectric strength | Sufficient to withstand 500 VAC at 50 Hz or 60 Hz applied between the windings and the frame for 1 minute after continuous operation under normal ambient temperature and humidity |
Temperature Rise | 18ºF (10ºC) or less measured by the thermometer method after the temperature of the case has stabilized after continuous operation under normal ambient temperature and humidity. |
Insulation Class | UL/CSA Standards: 105 (A), EN Standards: 120 (E) |
Overheat Protection | Built-in Overheat Protection Circuit |
Ambient temperature range | 14ºF ~ 140ºF (-10ºC ~ 60ºC) |
Ambient Humidity | 85% or less (noncondensing) |
Alarm Type | Electronic |
Alarm Activation Speed | 2100 ± 400 r/min |
Output Mode | Open-collector output |
Output Condition | Normal operation: L level (Internal transistor ON)Alarm output: H level (Internal transistor OFF) |
Maximum Rating | Maximum Applied Voltage: 30 VDC max.Maximum Inflow Current: 15 mA max. |
Delay Function | Built-In Starting Delay Time: 10 sec. max. (The alarm function starts monitoring within 10 sec. after the power is turned on.) |
Why Proax for Oriental Motor MDA1225-24?
Proax is the authorized distributor of Oriental Motor MDA1225-24. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Alternate Names | MDA122524 |
Pack Size | 1 |
Recommended