AF140N4-30-11-14
By ABB
SKU
ABBAF140N4301114
MPN
1SFL447001N1411
Weight
1.55 kg
The AF140N4-30-11-14 NEMA Contactor is a 3 pole - 1000 V IEC or 600 V UL contactor with double clamp, controlling motors up to 75 kW / 400 V AC (AC-3) or 100 hp / 480 V UL 200 A (AC-1) or 200 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (250-500 V, 50/60 Hz and DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.
Technical Specifications
Dimensions
| Product Net Width | 90 mm |
| Product Net Depth / Length | 126 mm |
| Product Net Height | 150 mm |
| Product Net Weight | 1.55 kg |
Technical
| Number of Main Contacts NO | 3 |
| Number of Main Contacts NC | 0 |
| Number of Auxiliary Contacts NO | 1 |
| Number of Auxiliary Contacts NC | 1 |
| Number of Poles | 3P |
| Standards | IEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1, UL 508, CSA C22.2 N°14 |
| Rated Operational Voltage | Main Circuit 1000 V |
| Rated Frequency (f) | Main Circuit 50 / 60 Hz |
| Conventional Free-air Thermal Current (Ith) | acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 200 A |
| Rated Operational Current AC-1 (Ie) | (690 V) 40 °C 200 A |
| Rated Operational Current AC-1 (Ie) | (690 V) 70 °C 160 A |
| Rated Operational Current AC-3 (Ie) | (415 V) 55 °C 140 A |
| Rated Operational Current AC-3 (Ie) | (440 V) 55 °C 140 A |
| Rated Operational Current AC-3 (Ie) | (500 V) 55 °C 130 A |
| Rated Operational Current AC-3 (Ie) | (690 V) 55 °C 80 A |
| Rated Operational Current AC-3 (Ie) | (380 / 400 V) 55 °C 140 A |
| Rated Operational Current AC-3 (Ie) | (220 / 230 / 240 V) 55 °C 140 A |
| Rated Operational Current DC-1 (Ie) | (110 V) 2 Poles in Series, 40 °C 160 A |
| Rated Operational Current DC-1 (Ie) | (220 V) 3 Poles in Series, 40 °C 160 A |
| Rated Operational Current DC-3 (Ie) | (110 V) 2 Poles in Series, 40 °C 160 A |
| Rated Operational Current DC-3 (Ie) | (220 V) 3 Poles in Series, 40 °C 160 A |
| Rated Operational Current DC-5 (Ie) | (110 V) 2 Poles in Series, 40 °C 160 A |
| Rated Operational Current DC-5 (Ie) | (220 V) 3 Poles in Series, 40 °C 160 A |
| Rated Operational Power AC-3 (Pe) | (415 V) 75 kW |
| Rated Operational Power AC-3 (Pe) | (440 V) 90 kW |
| Rated Operational Power AC-3 (Pe) | (500 V) 90 kW |
| Rated Operational Power AC-3 (Pe) | (690 V) 75 kW |
| Rated Operational Power AC-3 (Pe) | (380 / 400 V) 75 kW |
| Rated Operational Power AC-3 (Pe) | (220 / 230 / 240 V) 37 kW |
| Rated Breaking Capacity AC-3 | 8 x Ie AC-3 |
| Rated Breaking Capacity AC-3e | 8.5 x Ie AC-3e |
| Rated Making Capacity AC-3 | 10 x Ie AC-3 |
| Rated Making Capacity AC-3e | 12 x Ie AC-3e |
| Short-Circuit Protective Devices | gG Type Fuses 315 A |
| Rated Short-time Withstand Current Low Voltage (Icw) | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 200 A |
| Rated Short-time Withstand Current Low Voltage (Icw) | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 674 A |
| Rated Short-time Withstand Current Low Voltage (Icw) | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 1460 A |
| Rated Short-time Withstand Current Low Voltage (Icw) | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1168 A |
| Rated Short-time Withstand Current Low Voltage (Icw) | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 477 A |
| Maximum Breaking Capacity | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 3000 A |
| Maximum Breaking Capacity | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 1500 A |
| Rated Insulation Voltage (Ui) | acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V |
| Rated Insulation Voltage (Ui) | acc. to UL/CSA 600 V |
| Rated Impulse Withstand Voltage (Uimp) | Main Circuit 8 kV |
| Maximum Electrical Switching Frequency | (AC-1) 300 cycles per hour |
| Maximum Electrical Switching Frequency | (AC-2 / AC-4) 150 cycles per hour |
| Maximum Electrical Switching Frequency | (AC-3) 300 cycles per hour |
| Mechanical Durability | 5 million |
| Maximum Mechanical Switching Frequency | 300 cycles per hour |
| Coil Operating Limits | (acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C) |
| Rated Control Circuit Voltage (Uc) | 50 Hz 250...500 V |
| Rated Control Circuit Voltage (Uc) | 60 Hz 250...500 V |
| Rated Control Circuit Voltage (Uc) | DC Operation 250 ... 500 V |
| Coil Consumption | Holding at Max. Rated Control Circuit Voltage 50 Hz 16.1 V·A |
| Coil Consumption | Holding at Max. Rated Control Circuit Voltage 60 Hz 16.1 V·A |
| Coil Consumption | Holding at Max. Rated Control Circuit Voltage DC 4 V·A |
| Coil Consumption | Holding at Max. Rated Control Circuit Voltage DC 4 W |
| Coil Consumption | Pull-in at Max. Rated Control Circuit Voltage 50 Hz 205 V·A |
| Coil Consumption | Pull-in at Max. Rated Control Circuit Voltage 60 Hz 205 V·A |
| Coil Consumption | Pull-in at Max. Rated Control Circuit Voltage DC 204 V·A |
| Coil Consumption | Pull-in at Max. Rated Control Circuit Voltage DC 204 W |
| Power Loss | at Rated Operating Conditions per Pole 9 W |
| Operate Time | Between Coil De-energization and NO Contact Opening 37 ... 47 ms |
| Operate Time | Between Coil Energization and NO Contact Closing 25 ... 55 ms |
| Connecting Capacity Main Circuit | Flexible 2 x 10 ... 70 mm² |
| Connecting Capacity Main Circuit | Rigid Cu-Cable 2 x 10 ... 95 mm² |
| Connecting Capacity Auxiliary Circuit | Flexible with Ferrule 2x 0.75 ... 2.5 mm² |
| Connecting Capacity Auxiliary Circuit | Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² |
| Connecting Capacity Auxiliary Circuit | Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm² |
| Connecting Capacity Auxiliary Circuit | Flexible 2x 0.75 ... 2.5 mm² |
| Connecting Capacity Auxiliary Circuit | Flexible 2x0.75 ... 2.5 mm² |
| Connecting Capacity Auxiliary Circuit | Solid 2x 1 ... 4 mm² |
| Connecting Capacity Auxiliary Circuit | Solid 2 x 1 ... 4 mm² |
| Connecting Capacity Auxiliary Circuit | Stranded 2x 1 ... 4 mm² |
| Connecting Capacity Auxiliary Circuit | Stranded 2 x 1 .... 4 mm² |
| Connecting Capacity | Flexible 2 x 10 ... 70 mm² |
| Connecting Capacity | Rigid Cu-Cable 2 x 10 ... 95 mm² |
| Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP40 |
| Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 |
| Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00 |
| Tightening torque | Cable Lug 9 N·m |
| Tightening torque | Main Circuit 8 N·m |
| Terminal Type | Double Clamp |
| Product Name | Block Contactor |
Technical UL/CSA
| NEMA Size | 4 |
| Maximum Operating Voltage UL/CSA | Main Circuit 600 V |
ABB EcoSolutions
| End Of Life Disassembling Instructions | 1SFC100112M0001 |
Why Proax for ABB AF140N4-30-11-14?
Proax is an authorized distributor of ABB AF140N4-30-11-14 and one of ABB's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
| Alternate Names | AF140N4301114 |
| Pack Size | 1 |
Recommended