Phoenix ContactOfficial Distributor

By Phoenix Contact

SKU
MPN
NBC-M12FSY/2,0-94H
Weight
0.255 kg
Series NBC-M

NBC-M12FSY/2,0-94H - Hybrid cable

Hybrid cable, Ethernet hybrid CAT5 (100 Mbps), 8-position, PUR halogen-free, black RAL 9005, shielded (Tinned copper braided shield), Advanced Shielding Technology, Socket straight M12, coding: Y / IP65/IP67, on free cable end, cable length: 2 m, Power with Ethernet (PWE)

Technical Specifications

Product properties

ApplicationStandard
Sensor TypeEthernet hybrid
Number of Positions8
No. of cable outlets1
Shieldedyes
CodingY

Interfaces

Bus systemEthernet
Signal type/categoryEthernet hybrid CAT5 (IEC 11801), 100 Mbps

Signaling

Status displayNo
Status display presentNo

Electrical properties

Nominal voltage UN48 V AC (Power and data)
Nominal voltage UN50 V DC (Power and data)
Nominal current IN6 A (Power)
Nominal current IN0.5 A (Data)
Transmission mediumCopper

Material specifications

Flammability rating according to UL 94V0

Connection 1

Dimensional drawingM12 hybrid plug pin assignment, 8-pos., Y-coded, socket side view
TypeM12 Socket, straight, 8-position, AST, Keying: Y
Number of Positions8
Shieldedyes
Signal type/categoryEtherCAT® CAT5 (IEC 11801), 100 Mbps
Signal type/categoryPROFINET CAT5 (IEC 11801)
Insertion/withdrawal cycles≥ 100
Insulation resistance≥ 100 MΩ
Overvoltage categoryII
Degree of pollution3
Tightening torque0.4 Nm
Contact MaterialCuZn
Contact surface materialNi/Au
Contact carrier materialPA 6.6
Material for screw connectionZinc die-cast, nickel-plated
Seal materialFKM
Flammability rating according to UL 94V0
Degree of ProtectionIP65
Degree of ProtectionIP67
Ambient Temperature (Operation)-25 °C ... 85 °C
Standard designationM12 connector
Standards/regulationsIEC 61076-2-113

Connection 2

Typefree cable end

Cable/line

Cable Length2 m

Ethernet hybrid [94H]

Cable weight110 kg/km
UL AWM style20233 (80°C/300 V)
Number of Positions8
Shieldedyes
Cable TypeEthernet hybrid [94H]
Conductor structure1x4x AWG 26+1x4x AWG 18
Conductor structure signal line19x 0.10 mm
AWG Signal Line26
Conductor Cross Section4x 0.15 mm² (Data)
Conductor Cross Section4x 0.85 mm² (Power)
Wire diameter incl. insulation1.05 mm (Data)
Wire diameter incl. insulation1.4 mm (Power)
External Cable Diameter8.80 mm ±0.2 mm
Outer sheath, materialPUR
External sheath, colorblack RAL 9005
Conductor materialBare Cu litz wires
Material wire insulationPP (Data)
Material wire insulationPP (Power)
Single wire, colorwhite/orange, orange, white/green, green, white, blue, brown, black
Overall twist1 star quad and 4 wires with 2 fillers
Optical shield covering85 %
Insulation resistance≥ 5 GΩ*km
Loop resistance≤ 280.00 Ω/km (Data)
Loop resistance≤ 45.00 Ω/km (Power)
Wave impedance100 Ω ±15 Ω (4 MHz ... 100 MHz)
Working capacitancenom. 50 nF (per kilometer)
Differential impedance100 Ω ±5 % (at 100 MHz)
Nominal voltage, cable≤ 125 V (Peak value, not for high-power applications)
Test voltage Core/Core2000 V (50 Hz, 1 min.)
Test voltage Core/Shield2000.00 V (50 Hz, 1 min.)
Minimum bending radius, fixed installation4 x D
Minimum bending radius, flexible installation8 x D
Smallest bending radius, fixed installation36 mm
Smallest bending radius, movable installation71 mm
Max. bending cycles2000000
Tensile strength85 N (in accordance with DIN EN 50565-1 for flexible installation)
Tensile strength295 N (in accordance with DIN EN 50565-1 for fixed installation)
Near end crosstalk attenuation (NEXT)56.3 dB (at 4 МHz)
Near end crosstalk attenuation (NEXT)50.3 dB (at 10 MHz)
Near end crosstalk attenuation (NEXT)47.2 dB (at 16 MHz)
Near end crosstalk attenuation (NEXT)45.8 dB (at 20 МHz)
Near end crosstalk attenuation (NEXT)42.9 dB (at 31.25 МHz)
Near end crosstalk attenuation (NEXT)38.4 dB (at 62.5 МHz)
Near end crosstalk attenuation (NEXT)35.3 dB (at 100 MHz)
Shield attenuation6.2 dB (at 4 МHz)
Shield attenuation9.8 dB (at 10 MHz)
Shield attenuation12.4 dB (at 16 MHz)
Shield attenuation13.9 dB (at 20 МHz)
Shield attenuation17.6 dB (at 31.25 МHz)
Shield attenuation25.4 dB (at 62.5 МHz)
Shield attenuation32.8 dB (at 100 MHz)
Shield attenuation≥ 80.00 dB (30 MHz ... 100 MHz)
Halogen-freeaccording to IEC 60754-1
Halogen-freein accordance with DIN VDE 0472 part 815
Flame resistancein accordance with UL 1581, Section 1060
Flame resistancein acc. with UL 1581, section 1061
Flame resistancein accordance with UL 2556, Section 9.3
Resistance to Oilin accordance with IEC 60811-404
Resistance to OilAccording to DIN EN 50363-10-2
Other resistanceLow adhesion
Other resistanceHydrolysis resistance (DIN EN 50396)
Special PropertiesFree of substances which would hinder coating with paint or varnish
Special PropertiesSilicone-free
Ambient Temperature (Operation)-40 °C ... 80 °C (cable, fixed installation)
Ambient Temperature (Operation)-30 °C ... 70 °C (Cable, flexible installation)

Ambient conditions

Degree of ProtectionIP65
Degree of ProtectionIP67
Degree of ProtectionIP65/IP67

Standards and Regulations

Standard designationM12 connector
Standards/specificationsIEC 61076-2-113

Why Proax for Phoenix Contact 1149277?

Proax is an authorized distributor of Phoenix Contact 1149277 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Pack Size1
Recommended

Not in stock

Request lead time or order—we'll ensure quick delivery

Phoenix Contact Availability