Plug, M12 x 1, straight, shielded
1422762
SKU
PHX1422762
MPN
NBC-MS/ 1,0-94C
Weight
0.084 kg
Series NBC-MS
NBC-MS/ 1,0-94C - Network cable
Network cable, Ethernet CAT5, 8-position, PUR halogen-free, water blue RAL 5021, shielded (Tinned copper braided shield), Plug straight M12 SPEEDCON, on free cable end, cable length: 1 m
Technical Specifications
Product properties
| Sensor Type | Ethernet |
| Number of Positions | 8 |
| Shielded | yes |
| Coding | A |
Insulation characteristics
| Overvoltage category | III |
| Degree of pollution | 3 |
Interfaces
| Bus system | Ethernet |
| Signal type/category | Ethernet CAT5 (IEC 11801:2002) |
Signaling
| Status display | No |
| Status display present | No |
Electrical properties
| Nominal voltage UN | 30 V AC |
| Nominal voltage UN | 30 V DC |
| Nominal current IN | 2 A |
| Transmission medium | Copper |
| Transmission characteristics (category) | CAT5 (IEC 11801:2002) |
Connection 1
| Type | Plug straight M12 SPEEDCON |
| Locking Type | SPEEDCON |
Connection 2
| Type | free cable end |
Cable/line
| Cable Length | 1 m |
Ethernet drag chain CAT5, 4-pair [94C]
| Cable weight | 57 kg/km |
| UL AWM style | 20963 (80°C/30 V) |
| Number of Positions | 8 |
| Shielded | yes |
| Cable Type | Ethernet drag chain CAT5, 4-pair [94C] |
| Conductor structure | 4x2xAWG26/19, S/UTP |
| Signal runtime | 5.3 ns/m |
| Conductor structure signal line | 19x 0.10 mm |
| AWG Signal Line | 26 |
| Conductor Cross Section | 4x 2x 0.14 mm² |
| Wire diameter incl. insulation | 1 mm |
| External Cable Diameter | 6.90 mm +0.1 mm ... 0.2 mm |
| Outer sheath, material | PUR |
| External sheath, color | water blue RAL 5021 |
| Conductor material | Bare Cu litz wires |
| Material wire insulation | PP |
| Single wire, color | white/blue-blue, white/orange-orange, white/green-green, white/brown-brown |
| Thickness, outer sheath | 0.85 mm |
| Twisted pairs | 2 cores to the pair |
| Overall twist | Four pairs and four fillers to the core |
| Optical shield covering | 90 % |
| Insulation resistance | ≥ 500 MΩ*km |
| Coupling resistance | ≤ 100.00 mΩ/m (at 10 MHz) |
| Loop resistance | ≤ 290.00 Ω/km |
| Wave impedance | 100 Ω ±5 Ω (at 100 MHz) |
| Cable capacity | approx. 50 nF/km (at 1 kHz) |
| Nominal voltage, cable | ≤ 100 V |
| Test voltage Core/Core | 700 V (50 Hz, 1 min.) |
| Test voltage Core/Shield | 700.00 V (50 Hz, 1 min.) |
| Minimum bending radius, fixed installation | 4 x D |
| Minimum bending radius, flexible installation | 8 x D |
| Smallest bending radius, fixed installation | 28 mm |
| Smallest bending radius, movable installation | 56 mm |
| Max. bending cycles | 5000000 |
| Tensile strength | ≤ 100 N |
| Near end crosstalk attenuation (NEXT) | 65.3 dB (with 1 MHz) |
| Near end crosstalk attenuation (NEXT) | 56.3 dB (at 4 МHz) |
| Near end crosstalk attenuation (NEXT) | 50.3 dB (at 10 MHz) |
| Near end crosstalk attenuation (NEXT) | 47.2 dB (at 16 MHz) |
| Near end crosstalk attenuation (NEXT) | 45.8 dB (at 20 МHz) |
| Near end crosstalk attenuation (NEXT) | 42.9 dB (at 31.25 МHz) |
| Near end crosstalk attenuation (NEXT) | 38.4 dB (at 62.5 МHz) |
| Near end crosstalk attenuation (NEXT) | 35.3 dB (at 100 MHz) |
| Power-summated near end crosstalk attenuation (PSNEXT) | 62.3 dB (with 1 MHz) |
| Power-summated near end crosstalk attenuation (PSNEXT) | 53.3 dB (at 4 МHz) |
| Power-summated near end crosstalk attenuation (PSNEXT) | 47.3 dB (at 10 MHz) |
| Power-summated near end crosstalk attenuation (PSNEXT) | 44.2 dB (at 16 MHz) |
| Power-summated near end crosstalk attenuation (PSNEXT) | 42.8 dB (at 20 МHz) |
| Power-summated near end crosstalk attenuation (PSNEXT) | 39.9 dB (at 31.25 МHz) |
| Power-summated near end crosstalk attenuation (PSNEXT) | 35.4 dB (at 62.5 МHz) |
| Power-summated near end crosstalk attenuation (PSNEXT) | 32.3 dB (at 100 MHz) |
| Return attenuation (RL) | 23 dB (at 4 МHz) |
| Return attenuation (RL) | 24.1 dB (at 8 МHz) |
| Return attenuation (RL) | 25 dB (at 10 MHz) |
| Return attenuation (RL) | 25 dB (at 16 MHz) |
| Return attenuation (RL) | 25 dB (at 20 МHz) |
| Return attenuation (RL) | 23.6 dB (at 31.25 МHz) |
| Return attenuation (RL) | 21.5 dB (at 62.5 МHz) |
| Return attenuation (RL) | 20.1 dB (at 100 MHz) |
| Shield attenuation | 3.2 dB (with 1 MHz) |
| Shield attenuation | 6 dB (at 4 МHz) |
| Shield attenuation | 9.5 dB (at 10 MHz) |
| Shield attenuation | 12.1 dB (at 16 MHz) |
| Shield attenuation | 13.6 dB (at 20 МHz) |
| Shield attenuation | 17.1 dB (at 31.25 МHz) |
| Shield attenuation | 24.8 dB (at 62.5 МHz) |
| Shield attenuation | 32 dB (at 100 MHz) |
| Halogen-free | according to IEC 60754-1 |
| Flame resistance | according to IEC 60332-1-2 |
| Resistance to Oil | in accordance with EN 60811-2-1 |
| Ambient Temperature (Operation) | -40 °C ... 80 °C (cable, fixed installation) |
| Ambient Temperature (Operation) | -20 °C ... 80 °C (Cable, flexible installation) |
| Ambient temperature (installation) | -20 °C ... 80 °C |
Ambient conditions
| Degree of Protection | IP65 |
| Degree of Protection | IP67 |
| Degree of Protection | IP65/IP67 |
M12
| Standard designation | M12 connector |
| Standards/specifications | IEC 61076-2-101 |
Why Proax for Phoenix Contact 1422762?
Proax is an authorized distributor of Phoenix Contact 1422762 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
| Pack Size | 1 |
Recommended