EM-CPS-PS/3AC/24DC/20/8C/IOL - Power supply unit

Primary-switched power supply unit TRIO POWER, Snap-on connection, Cross Power System - installation, input: 3-phase, output: 24 V DC / 20 A

Technical Specifications

AC operation

Network TypeStar network
Nominal input voltage range3x 400 V AC ... 500 V AC
Input voltage range3x 400 V AC ... 500 V AC -20 % ... +15 %
Input Voltage Range AC3x 320 V AC ... 575 V AC
Typical national grid voltage3x 400 V AC
Typical national grid voltage3x 480 V AC
Voltage type of supply voltageAC
Inrush Current≤ 22 A (typical)
Inrush current integral (I2t)≤ 0.25 A2s
AC frequency range50 Hz ... 60 Hz
Mains buffering timetyp. 10 ms (400 V AC)
Mains buffering timetyp. 20 ms (500 V AC)
Current consumption3x 1.2 A (400 V AC)
Current consumption3x 1 A (500 V AC)
Nominal Power Consumption243.6 VA
Protective circuitTransient surge protection; Varistor
Power factor (cos phi)0.55
Typical response time< 1 s
Input fuse3.15 A (internal (device protection), slow-blow)
Recommended breaker for input protection6 A ... 16 A (AC: Characteristics B, C, D, K)
Discharge current to PE< 0.25 mA
Discharge current to PE< (550 V AC, 60 Hz)

Output data

Efficiency> 91 % (400 V AC)
Nominal Output Voltage24 V DC ±1 %
Setting range of the output voltage (USet)24 V DC ... 28 V DC (> 24 V DC, constant capacity restricted)
Nominal output current (IN)20 A
Dynamic Boost (IDyn.Boost)30 A (5 s)
Derating> 60 °C ... 70 °C (2.5 %/K)
Protection against overvoltage at the output (OVP)≤ 30 V DC
Control deviation< 1 % (change in load, static 10 % ... 90 %)
Control deviation< 3 % (Dynamic load change 10 % ... 90 %, 10 Hz)
Control deviation< 0.1 % (change in input voltage ±10 %)
Residual ripple≤ 20 mVPP
Short-circuit-proofyes
No-load proofyes
Output Power480 W
Output Power720 W
Maximum no-load power dissipation< 1 W (400 V AC)
Power loss nominal load max.< 12 W (480 V AC)
Rise time≤ 120 ms (UOUT (10 % ... 90 %))
Connection in parallelno
Connection in seriesNo

Signal: DC OK

Continuous load current100 mA

Signal relay 13/14

Defaultclosed
Digital30 V AC 30 V DC 100 mA

Input

Connection MethodSnap-on connection

Output

Connection MethodPush-in connection
Conductor cross section, rigid min.0.2 mm²
Conductor cross section, rigid max.4 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Single conductor/terminal point, stranded, with ferrule, min.0.2 mm²
Single conductor/terminal point, stranded, with ferrule, max.2.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.12
Stripping length10 mm

Signal

Connection MethodPush-in connection
Conductor cross section, rigid min.0.2 mm²
Conductor cross section, rigid max.1.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.1.5 mm²
Single conductor/terminal point, stranded, with ferrule, min.0.2 mm²
Single conductor/terminal point, stranded, with ferrule, max.1.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.16
Stripping length8 mm

Signaling

Types of signalingLED
Types of signalingFloating signal contact

Signal output: LED status indicator

Signalization designationDC OK
Status displayLED
Colorgreen
DC OKUOUT > 0.9 x UN (UN = 24 V DC)

Electrical properties

Number of phases3.00
Insulation voltage input/output3 kV AC (type test)
Insulation voltage input/output1.5 kV AC (routine test)

Product properties

Product familyTRIO POWER
MTBF (IEC 61709, SN 29500)> 850000 h (25 °C)
MTBF (IEC 61709, SN 29500)> 560000 h (40 °C)
MTBF (IEC 61709, SN 29500)> 290000 h (60 °C)

Insulation characteristics

Protection classI
Degree of pollution2

Dimensions

Width70.5 mm
Height209.7 mm
Depth170 mm

Installation dimensions

Installation distance right/left0 mm / 0 mm
Installation distance right/left (active)14 mm / 14 mm
Installation distance top/bottom50 mm / 50 mm
Installation distance top/bottom (active)50 mm / 50 mm

Mounting

Mounting TypeCross Power System - installation
Assembly instructionsCross Power System
With protective coatingNo

Material specifications

Flammability rating according to UL 94 (housing / terminal blocks)V0
Housing MaterialMetal

Ambient conditions

Degree of ProtectionIP20
Ambient Temperature (Operation)-25 °C ... 70 °C (> 60 °C Derating: 2,5 %/K)
Ambient temperature (storage/transport)-40 °C ... 85 °C
Maximum altitude≤ 4000 m (> 2000 m, Derating: 10 %/1000 m)
Climatic class3K3 (in acc. with EN 60721)
Max. permissible relative humidity (operation)≤ 95 % (at 25 °C, non-condensing)
Shock18 ms, 30g, in each space direction (according to IEC 60068-2-27)
Vibration (Operation)10 ... 150 Hz, amplitude ±0.35 mm, 5g, 90 min. (in accordance with IEC 60068-2-6)
Vibration (Operation)2 Hz ... 15 Hz, amplitude ±1 mm, > 15 Hz, 0.7g (in accordance with DNV GL Class A)

Standards and Regulations

Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installationsEN 50178/VDE 0160 (PELV)
Standard – Limitation of mains harmonic currentsEN 61000-3-2
Standard - Electrical safetyIEC 61010-1 (SELV)
Standard – Safety extra-low voltageIEC 61010 (SELV) / (PELV)
Standard - Safe isolationDIN VDE 0100-410
Standard - Safety of transformersEN 61558-2-16 (air clearances and creepage distances only)

Overvoltage category

EN 61010-1II

Approvals

UL approvalsUL Listed UL 61010-2-201

EMC data

Low Voltage DirectiveConformance with Low Voltage Directive 2014/35/EC
Interference emissionInterference emission in accordance with EN 61000-6-2 (industrial)
EMC requirements for noise immunityEN 61000-6-2
Electromagnetic compatibilityConformance with EMC Directive 2014/30/EU
Conducted noise emissionEN 55016
Conducted noise emissionEN 61000-6-3 (Class B)
Noise emissionEN 55011 (EN 55022)
Noise emissionEN 55016
Noise emissionEN 61000-6-3 (Class B)

Harmonic currents

Frequency RangeClass A, B

Flicker

Frequency Range0 kHz ... 2 kHz

Electrostatic discharge

Standards/regulationsEN 61000-4-2
Contact discharge6 kV (Test Level 4)
Discharge in air8 kV (Test Level 4)
CommentsCriterion B

Electromagnetic HF field

Standards/regulationsEN 61000-4-3
Frequency Range80 MHz ... 6 GHz
Test field strength10 V/m (Test Level 3)
CommentsCriterion A

Fast transients (burst)

Standards/regulationsEN 61000-4-4
Input4 kV (Test Level 4 - asymmetrical)
Output2 kV (Test Level 3 - asymmetrical)
Signal2 kV (Test Level 3 - asymmetrical)
CommentsCriterion B

Surge voltage load (surge)

Standards/regulationsEN 61000-4-5
Input1 kV (Test Level 1 - symmetrical)
Input2 kV (Test Level 1 - asymmetrical)
Output0.5 kV (Test Level 1 - symmetrical)
Output0.5 kV (Test Level 1 - asymmetrical)
Signal1 kV (Test Level 2 - asymmetrical)
CommentsCriterion B

Conducted interference

Standards/regulationsEN 61000-4-6
Input/Outputasymmetrical
Frequency Range0.15 MHz ... 80 MHz
CommentsCriterion A
Voltage10 V (Test Level 3)

Voltage dips

Standards/regulationsEN 61000-4-11
Voltage230 V AC
Frequency50 Hz
Voltage dip70 %
Number of periods25 periods
Additional textTest Level 2
CommentsCriterion A
Voltage dip40 %
Number of periods10 periods
Additional textTest Level 2
CommentsCriterion A
Voltage dip0 %
Number of periods1 period
Additional textTest Level 2
CommentsCriterion A

Criteria

Criterion ANormal operating behavior within the specified limits.
Criterion BTemporary impairment to operational behavior that is corrected by the device itself.

Why Proax for Phoenix Contact 1067898?

Proax is an authorized distributor of Phoenix Contact 1067898 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Pack Size1
Recommended

Available for order

Phoenix Contact Availability