Proax

Currency
0 Items
proax logo
Cart
Phoenix ContactOfficial Distributor

By Phoenix Contact

SKU
MPN
EM-CPS-PS/3AC/24DC/5
Weight
0.746 kg
Series EM-CPS-PS

EM-CPS-PS/3AC/24DC/5 - Power supply unit

Primary-switched power supply unit TRIO POWER, Snap-on connection, Cross Power System - installation, input: 3-phase, output: 24 V DC / 5 A

  • Push-in connections for easy 24 V DC control voltage connection
  • Fast startup: Tool-free mounting and automatic contacting in just one step (CrossPowerSystem)
  • Reliable startup of high loads, thanks to the dynamic boost
  • Electrically robust, thanks to high electric strength
  • Maximum flexibility, thanks to the temperature range of -25°C … +70°C and device startup at -40°C
Technical Specifications

AC operation

Network TypeStar network
Nominal input voltage range3x 400 V AC ... 500 V AC
Nominal input voltage range2x 400 V AC ... 500 V AC
Input voltage range3x 400 V AC ... 500 V AC -20 % ... +15 %
Input voltage range2x 400 V AC ... 500 V AC -10 % ... +15 %
Input Voltage Range AC3x 320 V AC ... 575 V AC
Typical national grid voltage3x 400 V AC
Typical national grid voltage3x 480 V AC
Voltage type of supply voltageAC
Inrush current integral (I2t)≤ 0.25 A2s
Inrush current limitation≤ 22 A
AC frequency range50 Hz ... 60 Hz
Mains buffering timetyp. 20 ms (400 V AC)
Mains buffering timetyp. 20 ms (500 V AC)
Current consumption3x 0.4 A (400 V AC)
Current consumption3x 0.3 A (500 V AC)
Current consumption2x 0.6 A (400 V AC)
Current consumption2x 0.5 A (500 V AC)
Nominal Power Consumption243.6 VA
Protective circuitTransient surge protection; Varistor
Power factor (cos phi)0.55
Typical response time< 1 s
Input fuse3.15 A (internal (device protection), slow-blow)
Discharge current to PE< 0.25 mA
Discharge current to PE< (550 V AC, 60 Hz)

Output data

Efficiencytyp. 91 % (400 V AC)
Nominal Output Voltage24 V DC ±1 %
Setting range of the output voltage (USet)24 V DC ... 28 V DC (> 24 V DC, constant capacity restricted)
Nominal output current (IN)5 A
Dynamic Boost (IDyn.Boost)7.5 A (5 s)
Derating> 60 °C ... 70 °C (2.5 %/K)
Protection against overvoltage at the output (OVP)≤ 30 V DC
Control deviation< 1 % (change in load, static 10 % ... 90 %)
Control deviation< 3 % (Dynamic load change 10 % ... 90 %, 10 Hz)
Control deviation< 0.1 % (change in input voltage ±10 %)
Residual ripple≤ 20 mVPP
Short-circuit-proofyes
No-load proofyes
Output Power120 W
Output Power180 W
Maximum no-load power dissipation< 1 W (400 V AC)
Power loss nominal load max.< 12 W (480 V AC)
Rise time≤ 120 ms (UOUT (10 % ... 90 %))
Connection in parallelyes, for redundancy and increased capacity
Connection in seriesyes

Signal: DC OK

Continuous load current100 mA

Signal relay 13/14

Defaultclosed
Digital30 V AC 30 V DC 100 mA

Input

Connection MethodSnap-on connection

Output

Connection MethodPush-in connection
Conductor cross section, rigid min.0.2 mm²
Conductor cross section, rigid max.4 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Single conductor/terminal point, stranded, with ferrule, min.0.2 mm²
Single conductor/terminal point, stranded, with ferrule, max.2.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.12
Stripping length10 mm

Signal

Connection MethodPush-in connection
Conductor cross section, rigid min.0.2 mm²
Conductor cross section, rigid max.1.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.1.5 mm²
Single conductor/terminal point, stranded, with ferrule, min.0.2 mm²
Single conductor/terminal point, stranded, with ferrule, max.1.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.16
Stripping length8 mm

Signaling

Types of signalingLED
Types of signalingFloating signal contact

Signal output: LED status indicator

Signalization designationDC OK
Status displayLED
Colorgreen
DC OKUOUT > 0.9 x UN (UN = 24 V DC)

Electrical properties

Number of phases3.00
Insulation voltage input/output3 kV AC (type test)
Insulation voltage input/output1.5 kV AC (routine test)

Product properties

Product familyTRIO POWER
MTBF (IEC 61709, SN 29500)> 2300000 h (25 °C)
MTBF (IEC 61709, SN 29500)> 1300000 h (40 °C)
MTBF (IEC 61709, SN 29500)> 620000 h (60 °C)

Insulation characteristics

Protection classII (in closed control cabinet)
Degree of pollution2

Dimensions

Width36 mm
Height160 mm
Depth159 mm

Installation dimensions

Installation distance right/left0 mm / 0 mm
Installation distance right/left (active)14 mm / 14 mm
Installation distance top/bottom50 mm / 50 mm
Installation distance top/bottom (active)50 mm / 50 mm

Mounting

Mounting TypeCross Power System - installation
Assembly instructionsCross Power System
With protective coatingNo

Material specifications

Flammability rating according to UL 94 (housing / terminal blocks)V0
Housing MaterialPlastic
Type of housingPolycarbonate
Hood versionPolycarbonate

Ambient conditions

Degree of ProtectionIP20
Ambient Temperature (Operation)-25 °C ... 70 °C (> 60 °C Derating: 2,5 %/K)
Ambient temperature (storage/transport)-40 °C ... 85 °C
Maximum altitude≤ 4000 m (> 2000 m, Derating: 10 %/1000 m)
Climatic class3K3 (in acc. with EN 60721)
Max. permissible relative humidity (operation)≤ 95 % (at 25 °C, non-condensing)
Shock18 ms, 30g, in each space direction (according to IEC 60068-2-27)
Vibration (Operation)10 ... 150 Hz, amplitude ±0.35 mm, 5g, 90 min. (in accordance with IEC 60068-2-6)
Vibration (Operation)2 Hz ... 15 Hz, amplitude ±1 mm, > 15 Hz, 0.7g (in accordance with DNV GL Class A)

Standards and Regulations

Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installationsEN 50178/VDE 0160 (PELV)
Standard – Limitation of mains harmonic currentsEN 61000-3-2
Standard - Electrical safetyIEC 61010-1 (SELV)
Standard – Safety extra-low voltageIEC 61010 (SELV) / (PELV)
Standard - Safe isolationDIN VDE 0100-410
Standard - Safety of transformersEN 61558-2-16 (air clearances and creepage distances only)

Overvoltage category

EN 61010-1II

Approvals

UL approvalsUL Listed UL 61010-2-201

Conformity/Approvals

SIL in accordance with IEC 615080

EMC data

Low Voltage DirectiveConformance with Low Voltage Directive 2014/35/EC
Interference emissionInterference emission in accordance with EN 61000-6-2 (industrial)
EMC requirements for noise immunityEN 61000-6-2
Electromagnetic compatibilityConformance with EMC Directive 2014/30/EU
Conducted noise emissionEN 55016
Conducted noise emissionEN 61000-6-4 (Class A)
Noise emissionEN 55011 (EN 55022)
Noise emissionEN 55016
Noise emissionEN 61000-6-4 (Class A)

Harmonic currents

Frequency RangeClass A, B

Flicker

Frequency Range0 kHz ... 2 kHz

Electrostatic discharge

Standards/regulationsEN 61000-4-2
Contact discharge6 kV (Test Level 4)
Discharge in air8 kV (Test Level 4)
CommentsCriterion A

Electromagnetic HF field

Standards/regulationsEN 61000-4-3
Frequency Range80 MHz ... 6 GHz
Test field strength10 V/m (Test Level 3)
CommentsCriterion A

Fast transients (burst)

Standards/regulationsEN 61000-4-4
Input4 kV (Test Level 4 - asymmetrical)
Output2 kV (Test Level 3 - asymmetrical)
Signal1 kV (Test Level 2 - asymmetrical)
CommentsCriterion A

Surge voltage load (surge)

Input2 kV (Test Level 1 - asymmetrical)
Output0.5 kV (Test Level 1 - asymmetrical)

Conducted interference

Standards/regulationsEN 61000-6-2

Voltage dips

Standards/regulationsEN 61000-4-11
Voltage230 V AC
Frequency50 Hz
Voltage dip70 %
Number of periods25 periods
Additional textTest Level 2
CommentsCriterion A
Voltage dip40 %
Number of periods10 periods
Additional textTest Level 2
CommentsCriterion A
Voltage dip0 %
Number of periods1 period
Additional textTest Level 2
CommentsCriterion A

Criteria

Criterion ANormal operating behavior within the specified limits.
Criterion BTemporary impairment to operational behavior that is corrected by the device itself.
Accessories

Why Proax for Phoenix Contact 1064922?

Proax is an authorized distributor of Phoenix Contact 1064922 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Pack Size1
Recommended

Not in stock

Request lead time or order—we'll ensure quick delivery

Phoenix Contact Availability