The figure shows a 7-position version
SKU
MPN
HDFK 16
Weight
0.04 kg
This product is Not Cancellable/Not Returnable
Series HDFK
HDFK 16 - Panel feed-through terminal block
Panel feed-through terminal block, connection method: Screw connection with tension sleeve, Screw connection with tension sleeve, number of positions: 1, load current: 76 A, cross section: 0.5 mm2 - 25 mm2, connection direction of the conductor to plug-in direction: 0 °, width: 12 mm
- Well-known connection principle allows worldwide use
- Low temperature rise, thanks to maximum contact force
- Tool-free snap-in principle enables easy mounting on the device panel
- Automatic panel thickness compensation enables universal use
Technical Specifications
Product properties
Product family | HDFK 16 |
Number of Positions | 1 |
Pitch | 12.1 mm |
Number of Connections | 2 |
Number of rows | 1 |
Number of potentials | 1 |
Insulation characteristics
Overvoltage category | III |
Degree of pollution | 3 |
Electrical properties
Nominal current IN | 76 A |
Nominal voltage UN | 500 V |
Degree of pollution | 3 |
Rated voltage (III/3) | 500 V |
Rated surge voltage (III/3) | 6 kV |
Connection technology
Connector system | HDFK 16 |
Nominal cross section | 16 mm² |
Conductor connection exterior
Connection Method | Screw connection with tension sleeve |
Connection direction of the conductor to plug-in direction | 0 ° |
Conductor cross section rigid | 0.5 mm² ... 25 mm² |
Conductor cross section flexible | 0.5 mm² ... 16 mm² |
Conductor cross section flexible, with ferrule without plastic sleeve | 0.5 mm² ... 16 mm² |
Conductor cross section, flexible, with ferrule, with plastic sleeve | 0.5 mm² ... 16 mm² |
2 conductors with same cross section, solid | 0.5 mm² ... 6 mm² |
2 conductors with same cross section, flexible | 0.5 mm² ... 6 mm² |
2 conductors with same cross section, flexible, with ferrule without plastic sleeve | 0.5 mm² ... 6 mm² |
2 conductors with the same cross section, flexible, with TWIN ferrule with plastic sleeve | 0.5 mm² ... 6 mm² |
Internal cylindrical gage | B7 |
Stripping length | 16 mm |
Tightening torque | 2 Nm ... 2.3 Nm |
Conductor connection interior
Connection Method | Screw connection with tension sleeve |
Connection direction of the conductor to plug-in direction | 0 ° |
Conductor cross section rigid | 0.5 mm² ... 25 mm² |
Conductor cross section flexible | 0.5 mm² ... 16 mm² |
Conductor cross section flexible, with ferrule without plastic sleeve | 0.5 mm² ... 16 mm² |
Conductor cross section, flexible, with ferrule, with plastic sleeve | 0.5 mm² ... 16 mm² |
2 conductors with same cross section, solid | 0.5 mm² ... 6 mm² |
2 conductors with same cross section, flexible | 0.5 mm² ... 6 mm² |
2 conductors with same cross section, flexible, with ferrule without plastic sleeve | 0.5 mm² ... 6 mm² |
2 conductors with the same cross section, flexible, with TWIN ferrule with plastic sleeve | 0.5 mm² ... 6 mm² |
Internal cylindrical gage | B7 |
Stripping length | 16 mm |
Tightening torque | 2 Nm ... 2.3 Nm |
Material data - contact
Note | WEEE/RoHS-compliant, free of whiskers according to IEC 60068-2-82/JEDEC JESD 201 |
Contact Material | Cu alloy |
Surface characteristics | tin-plated |
Material data - housing
Color (Housing) | gray (7042) |
Insulating material | PA |
Insulating material group | I |
CTI according to IEC 60112 | 600 |
Flammability rating according to UL 94 | V0 |
Glow wire flammability index GWFI according to EN 60695-2-12 | 850 |
Glow wire ignition temperature GWIT according to EN 60695-2-13 | 775 |
Temperature for the ball pressure test according to EN 60695-10-2 | 125 °C |
Safety note
Safety note | • Only electrically qualified personnel may install and operate the product.To recognize and prevent danger, the qualified personnel must be familiar with the basics of electrical engineering. |
Safety note | • Observe the technical data provided here and refer to the documents listed under “Downloads”. The download area contains important information, such as installation notes, technical drawings, and 3D data. |
Safety note | • The cable entry funnel is not safe to touch. Never connect or disconnect the terminal when it is energized. Take appropriate steps to ensure touch protection. |
Safety note | There is no electrical contact to the housing. Make sure that protective grounding is provided for green/yellow color variants and articles marked with PE. |
Dimensions
Pitch | 12.1 mm |
Width [w] | 12 mm |
External dimensions
Height [h1] | 40 mm |
Length [l1] | 32.3 mm |
Internal dimensions
Height [h2] | 38.1 mm |
Length [l2] | 26.5 mm |
Air clearances and creepage distances | 1. Insulation coordination
Insulating material group | I |
Comparative tracking index (IEC 60112) | CTI 600 |
Rated insulation voltage (III/3) | 500 V |
Rated surge voltage (III/3) | 6 kV |
minimum clearance value - non-homogenous field (III/3) | 5.5 mm |
minimum creepage distance (III/3) | 6.3 mm |
Packaging specifications
Type of packaging | packed in cardboard |
Why Proax for Phoenix Contact 3001721?
Proax is an authorized distributor of Phoenix Contact 3001721 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size | 50 |
Recommended
- HDFK 10A - Panel feed-through terminal block, connection method: Screw connection with tension sleeve, Screw connection with tension sleeve, number of positions: 1, load current: 57 A, cross section: 0.5 mm2 - 16 mm2, connection direction of the conductor to plug-in direction: 0 °, width: 10.1 mm. External part, with current bar
- HDFK 10A GNYE - Panel feed-through terminal block, connection method: Screw connection with tension sleeve, Screw connection with tension sleeve, number of positions: 1, load current: 57 A, cross section: 0.5 mm2 - 16 mm2, connection direction of the conductor to plug-in direction: 0 °, width: 10.1 mm
- HDFK 10A WH (VPE1000) - Panel feed-through terminal block, connection method: Screw connection with tension sleeve, Screw connection with tension sleeve, number of positions: 1, load current: 57 A, cross section: 0.5 mm2 - 16 mm2, connection direction of the conductor to plug-in direction: 0 °, width: 10.1 mm
- HDFK 10I - Panel feed-through terminal block, connection method: Screw connection with tension sleeve, Screw connection with tension sleeve, number of positions: 1, load current: 57 A, cross section: 0.5 mm2 - 16 mm2, connection direction of the conductor to plug-in direction: 0 °, width: 10.1 mm. Internal part, without current bar
- HDFK 10I-AMK - Panel feed-through terminal block, connection method: Screw connection with tension sleeve, Screw connection with tension sleeve, number of positions: 1, load current: 57 A, cross section: 0.5 mm2 - 16 mm2, connection direction of the conductor to plug-in direction: 0 °, width: 10.1 mm