UM-4SL/SPT/ADR541/CS - Passive module
Interface module for the connection of the field side via spring-cage connection to the Yokogawa ADR 541 card. Fuse (5 x 20) with fuse failure display (LED) per channel. AKB 334 system connection to the controller.
Technical Specifications
Product properties
| Operating mode | 100% operating factor |
Insulation characteristics: Air clearances and creepage distances between the power circuits
| Overvoltage category | II |
| Pollution degree | 2 |
Electrical properties
| Max. permissible current | 630 mA (per path, protected by fuse (5x20 slow-blow)) |
| Max. permissible total current | 6.3 A |
| Nominal voltage UN | 24 V DC |
| Nominal voltage UN | 19.2 V DC ... 30 V DC |
Air clearances and creepage distances between the power circuits
| Rated Insulation Voltage | 50 V DC |
| Rated surge voltage | 0.5 kV (Functional insulation) |
Supported controller YOKOGAWA CS3000 CentumVP
| Suitable I/O card | ADR541 |
Field level
| Connection Method | Spring-cage connection |
| Number of Positions | 32 |
| Conductor cross section rigid | 0.2 mm² ... 4 mm² |
| Conductor cross section flexible | 0.2 mm² ... 2.5 mm² |
| Conductor cross section AWG | 24 ... 12 |
Controller level
| Connection Method | COMBICON connectors |
| Number of Connections | 4 |
| Number of Positions | 18 |
| Note | Yokogawa AKB334-compatible |
Signaling
| Status display present | Yes, if the fuse fails |
| Operating voltage display | Green LED |
Item dimensions
| Width | 232 mm |
| Height | 125.4 mm |
| Depth | 98.3 mm |
Ambient conditions
| Degree of Protection | IP00 |
| Degree of protection (Installation location) | ≥ IP54 (Installation location) |
| Ambient Temperature (Operation) | -20 °C ... 50 °C |
| Ambient temperature (storage/transport) | -20 °C ... 70 °C |
| Altitude | ≤ 2000 m |
Air clearances and creepage distances between the power circuits
| Standards/regulations | DIN EN 50178 |
Mounting
| Mounting Type | DIN rail mounting |
| Assembly instructions | in rows with zero spacing |
| Mounting Position | any |
Notes
| Notes on operation | Voltage monitoring on the module does not work in combination with upstream HESILED fuse terminal blocks with integrated LED display. |
| Notes on operation | No additional touch protection is required when using a SELV/PELV voltage (≤ 25 V AC or 60 V DC). |
| Notes on operation | At least one functional insulation against adjacent modules is complied with (in the support rail direction). If the application has stricter requirements for the insulation (basic insulation or reinforced insulation), they must be realized by applying suitable measures (e. g. partition plates). |
| Notes on operation | For proper use, the specifications of the installation directive (see Downloads) must be observed. For applications or use with third-party products, the specifications, and the safety and warning instructions of the respective third-party manufacturer must also be met. |
Why Proax for Phoenix Contact 2968522?
Proax is an authorized distributor of Phoenix Contact 2968522 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
| Pack Size | 1 |
Recommended