DEK-OE-230AC/ 48DC/100/SO 46 - Solid-state relay terminal block
Solid-state relay interface designed to prevent interference on the control side, input: 230 V AC, output: 48 V DC/100 mA
- Use of AC output cards, resulting in residual AC currents
- Resistant to interference currents
- Applications with long control lines
- High relay release voltage
Technical Specifications
Notes
Order information: | The housing is open on one side. The appropriate cover is D-DEK 1,5 GN (2716949). |
Note on application | Use of EB 80-DIK... bridges in the DEK terminal blocks: Absorption of humidity from the ambient air as well as an unfavorable tolerance between a larger number of DEK terminal blocks and the EB 80-DIK... bridge may cause (minor) expansion of the DEK housing. When the EB 80-DIK... bridges are used, therefore, it is recommended that these be disconnected after about 10 to 12 DEK terminal blocks and a wire bridge to the next DEK terminal block be inserted in their place. |
Product properties
Product family | DEK |
Application | Filter to prevent interference |
Operating mode | 100% operating factor |
Insulation characteristics
Insulation | Basic insulation |
Insulation | Basic insulation |
Overvoltage category | III |
Pollution degree | 2 |
Electrical properties
Test voltage (Input/output) | 2.5 kV AC (Input/output) |
Input data
Nominal input voltage UN | 230 V AC |
Input voltage range in reference to UN | 0.9 ... 1.1 |
Input voltage range | 207 V AC ... 253 V AC |
Switching threshold "0" signal, voltage | ≤ 92 V AC |
Switching threshold "1" signal voltage | > 207 V AC |
Typical input current at UN | 2.5 mA |
Typical response time | 4.4 ms |
Typical turn-off time | 14 ms |
Operating voltage display | Yellow LED |
Protective circuit | Surge protection; Varistor |
Protective circuit | RC element; RC element |
Transmission frequency | 5 Hz |
Output data
Contact switching type | 1 N/O contact |
Design of digital output | electronic |
Output voltage range | 3 V DC ... 48 V DC |
Limiting Continuous Current | 100 mA |
Voltage drop at max. limiting continuous current | ≤ 0.9 V |
Output circuit | 3-conductor, ground-referenced |
Protective circuit | Reverse polarity protection; Polarity protection diode |
Protective circuit | Free running; Freewheeling diode |
Connection data
Connection Method | Screw connection |
Stripping length | 8 mm |
Screw thread | M3 |
Conductor cross section rigid | 0.2 mm² ... 2.5 mm² |
Conductor cross section flexible | 0.2 mm² ... 2.5 mm² |
Conductor cross section AWG | 24 ... 14 |
Tightening torque | 0.5 Nm |
Dimensions
Width | 6.2 mm |
Height | 80 mm |
Depth | 56 mm |
Material specifications
Color | green (RAL 6021) |
Ambient conditions
Ambient Temperature (Operation) | 0 °C ... 50 °C |
Ambient temperature (storage/transport) | 0 °C ... 70 °C |
Standards and Regulations
Standards/regulations | IEC 60947-5-1 |
Mounting
Mounting Type | DIN rail mounting |
Assembly instructions | in rows with zero spacing |
Mounting Position | any |
Accessories
Why Proax for Phoenix Contact 2964678?
Proax is an authorized distributor of Phoenix Contact 2964678 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size | 10 |
Recommended