SKU
MPN
DEK-REL- 5/I/1
Weight
0.022 kg
This product is Not Cancellable/Not Returnable
Series DEK-REL
DEK-REL- 5/I/1 - Relay Module
Relay terminal block, with soldered-in miniature relays, contact (AgNi+Au): small to medium loads, 1 N/O contact, input voltage 5 V AC/DC, for assembly on NS 35/7.5, terminal width 6.2 mm
- Reduced costs as N terminal block is no longer required
- Up to 73 % more space
- Wiring reduced to a minimum
- 2-layer contact with hard gold plating for universal applications from 1 mA to 5 A continuous current
- 2 kVrms electrical isolation between input and output
- Integrated input circuit
Technical Specifications
Notes
Note on application | Use of EB 80-DIK... bridges in the DEK terminal blocks: Absorption of humidity from the ambient air as well as an unfavorable tolerance between a larger number of DEK terminal blocks and the EB 80-DIK... bridge may cause (minor) expansion of the DEK housing. When the EB 80-DIK... bridges are used, therefore, it is recommended that these be disconnected after about 10 to 12 DEK terminal blocks and a wire bridge to the next DEK terminal block be inserted in their place. |
Product properties
Product family | DEK |
Application | Output function |
Operating mode | 100% operating factor |
Mechanical service life | approx. 2x 10⁷ cycles |
Insulation characteristics
Insulation | Basic insulation |
Insulation | Basic insulation |
Overvoltage category | III |
Pollution degree | 2 |
Electrical properties
Maximum power dissipation for nominal condition | 0.12 W |
Test voltage (Winding/contact) | 2 kV AC (50 Hz, 1 min., winding/contact) |
Coil side
Nominal input voltage UN | 5 V AC/DC |
Input voltage range | 4.5 V AC/DC ... 5.5 V AC/DC (20 °C) |
Drive and function | monostable |
Drive (polarity) | polarized |
Typical input current at UN | 23 mA |
Typical response time | 8 ms |
Typical release time | 15 ms |
Protective circuit | Bridge rectifier; Bridge rectifier |
Operating voltage display | Yellow LED |
Switching
Contact switching type | 1 N/O contact |
Type of switch contact | Double contact |
Contact Material | AgNi, hard gold-plated |
Maximum Switching Voltage | 250 V AC |
Maximum Switching Voltage | 125 V DC |
Minimum Switching Voltage | 0.1 V |
Limiting Continuous Current | 3 A (5 A up to 35°C at 24 V DC) |
Maximum Inrush Current | 5 A |
Min. switching current | 1 mA |
Interrupting rating (ohmic load) max. | 72 W (at 24 V DC) |
Interrupting rating (ohmic load) max. | 60 W (at 48 V DC) |
Interrupting rating (ohmic load) max. | 50 W (at 60 V DC) |
Interrupting rating (ohmic load) max. | 50 W (at 110 V DC) |
Interrupting rating (ohmic load) max. | 750 VA (for 250 V AC) |
Interrupting rating (ohmic load) max. | 120 W (at 24 V DC - up to 35°) |
Connection data
Connection Method | Screw connection |
Stripping length | 8 mm |
Screw thread | M3 |
Conductor cross section rigid | 0.2 mm² ... 2.5 mm² |
Conductor cross section flexible | 0.2 mm² ... 2.5 mm² |
Conductor cross section AWG | 24 ... 14 |
Tightening torque | 0.5 Nm |
Dimensions
Width | 6.2 mm |
Height | 80 mm |
Depth | 56 mm |
Material specifications
Color | green (RAL 6021) |
Ambient conditions
Ambient Temperature (Operation) | -20 °C ... 50 °C |
Ambient temperature (storage/transport) | -20 °C ... 70 °C |
Standards and Regulations
Standards/regulations | IEC 60947-5-1 |
Mounting
Mounting Type | DIN rail mounting |
Assembly instructions | in rows with zero spacing |
Mounting Position | any |
Accessories
Why Proax for Phoenix Contact 2941183?
Proax is an authorized distributor of Phoenix Contact 2941183 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size | 1 |
Recommended