2902879
SKU
PHX2902879
MPN
QUINT-ORING/24DC/2X40/1X80
Weight
1.2 kg
Series QUINT-ORING
QUINT-ORING/24DC/2X40/1X80 - Redundancy module
Active QUINT redundancy module for DIN rail mounting with ACB (Auto Current Balancing) Technology and monitoring functions, input: 24 V DC/2x 40 A, output: 24 V DC/1 x 80 A, including mounted UTA 107/30 universal DIN rail adapter
- Service life of the redundant solution is doubled, thanks to uniform distribution of the load
- Save energy
- Permanent monitoring of redundancy
- Consistent redundancy up to the load
Technical Specifications
DC operation
| Nominal input voltage range | 24 V DC |
| Input voltage range | 18 V DC ... 28 V DC (SELV) |
| Input voltage range DC | 18 V DC ... 28 V DC (SELV) |
| Voltage type of supply voltage | DC |
| Reverse polarity protection | < yes60 V |
| Nominal input current (IN) | 2x 40 A (-25 °C ... 60 °C) |
| Nominal input current (IN) | 1x 80 A (-25 °C ... 60 °C) |
| Maximum current Imax | 2x 45 A (-25 °C ... 40 °C) |
| Maximum current Imax | 1x 90 A (-25 °C ... 40 °C) |
| Maximum current Imax | 215 A (12 ms, SFB Technology) |
| Transient surge protection | Varistor |
| Voltage drop, input/output | 0.2 V (IOUT = 80 A) |
Output data
| Efficiency | > 98 % |
| Nominal Output Voltage | UIn - 0,2 V |
| Nominal output current (IN) | 80 A (Increasing power) |
| Nominal output current (IN) | 40 A (Redundancy) |
| Derating | 60 °C ... 70 °C (2.5 %/K) |
| Protection against overvoltage at the output (OVP) | ≤ 32 V DC |
| Power loss nominal load max. | 16 W (IOUT = 80 A) |
| Connection in series | No |
Signal: Redundancy OK, 13/14
| Output description | Group contact |
| Maximum Switching Voltage | max. 30 V AC/DC |
| Maximum Inrush Current | ≤ 100 mA (short-circuit-proof) |
Signal: ACB (Auto Current Balancing) OK, 23/24
| Output description | Contact closed: Δ UIN ≤ 300 mV |
| Maximum Switching Voltage | max. 30 V AC/DC |
| Maximum Inrush Current | ≤ 100 mA (short-circuit-proof) |
Signal
| Maximum Inrush Current | ≤ 100 mA (short-circuit-proof) |
Input
| Connection Method | Screw connection |
| Conductor cross section, rigid min. | 0.5 mm² |
| Conductor cross section, rigid max. | 16 mm² |
| Conductor cross section flexible min. | 0.5 mm² |
| Conductor cross section flexible max. | 16 mm² |
| Conductor cross section AWG min. | 6 |
| Stripping length | 10 mm |
| Screw thread | M4 |
| Tightening torque, min | 1.2 Nm |
| Tightening torque max | 1.5 Nm |
Output
| Connection Method | Screw connection |
| Conductor cross section, rigid min. | 0.5 mm² |
| Conductor cross section, rigid max. | 35 mm² |
| Conductor cross section flexible min. | 0.5 mm² |
| Conductor cross section flexible max. | 35 mm² |
| Conductor cross section AWG min. | 2 |
| Stripping length | 18 mm |
| Screw thread | M5 |
| Tightening torque, min | 2.5 Nm |
| Tightening torque max | 4.5 Nm |
Signal
| Connection Method | Screw connection |
| Conductor cross section, rigid min. | 0.2 mm² |
| Conductor cross section, rigid max. | 6 mm² |
| Conductor cross section flexible min. | 0.2 mm² |
| Conductor cross section flexible max. | 4 mm² |
| Conductor cross section AWG min. | 16 |
| Conductor cross section AWG max. | 10 |
| Stripping length | 10 mm |
| Screw thread | M3 |
| Tightening torque, min | 0.5 Nm |
| Tightening torque max | 0.6 Nm |
Signaling
| Types of signaling | Relay contact, floating, current limited |
Signal output: Redundancy OK, 13/14
| Status display | LED redundancy OK |
| Note on status display | green |
Signal output: ACB (Auto Current Balancing) OK, 23/24
| Status display | ACB OK LED |
| Note on status display | LED bar graph green |
Electrical properties
| Insulation voltage input, output / housing | 500 V |
Product properties
| Product family | QUINT ORING |
| MTBF (IEC 61709, SN 29500) | > 720000 h (40 °C) |
| LED | yes |
Insulation characteristics
| Protection class | III |
| Degree of pollution | 2 |
Dimensions
| Width | 66 mm |
| Height | 130 mm |
| Depth | 125 mm |
| Horizontal pitch | 3.7 Div. |
Installation dimensions
| Installation distance right/left | 5 mm / 5 mm |
| Installation distance top/bottom | 50 mm / 50 mm |
Alternative assembly
| Width | 122 mm |
| Height | 130 mm |
| Depth | 69 mm |
Mounting
| Mounting Type | DIN rail: 35 mm |
| Assembly instructions | alignable: PN ≥50%, 5 mm horizontally, 15 mm next to active components, 50 mm verticallyalignable: PN <50%, 0 mm horizontally, 40 mm vertically top, 20 mm vertically bottom |
| Mounting Position | horizontal DIN rail NS 35, EN 60715 |
Material specifications
| Housing Material | Metal |
| Type of housing | Aluminum (AlMg3) |
| Hood version | Galvanized sheet steel, free from chrome (VI) |
Ambient conditions
| Degree of Protection | IP20 |
| Ambient Temperature (Operation) | -25 °C ... 70 °C (> 60 °C Derating: 2,5 %/K) |
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
| Ambient temperature (start-up type tested) | -40 °C |
| Maximum altitude | 2000 m |
| Maximum altitude | 2000 m |
| Climatic class | 3K3 (in acc. with EN 60721) |
| Max. permissible relative humidity (operation) | ≤ 95 % (at 25 °C, non-condensing) |
| Shock | 18 ms, 30g, in each space direction (according to IEC 60068-2-27) |
| Vibration (Operation) | < 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6) |
| Vibration (Operation) | 15 Hz ... 150 Hz, 2.3g, 90 min. |
Standards and Regulations
| Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations | EN 50178/VDE 0160 (PELV) |
| Standard - Electrical safety | EN 60950-1/VDE 0805 (SELV) |
| Standard – Safety extra-low voltage | IEC 60950-1 (SELV) and EN 60204-1 (PELV) |
Approvals
| UL approvals | UL/C-UL listed UL 508 |
| UL approvals | UL/C-UL Recognized UL 60950-1 |
| UL approvals | UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D (Hazardous Location) |
Conformity/Approvals
| SIL in accordance with IEC 61508 | 0 |
EMC data
| Low Voltage Directive | Conformance with Low Voltage Directive 2014/35/EC |
| EMC requirements for noise emission | EN 61000-6-3 |
| EMC requirements for noise emission | EN 61000-6-4 |
| EMC requirements for noise immunity | EN 61000-6-1 |
| EMC requirements for noise immunity | EN 61000-6-2 |
| Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
Electrostatic discharge
| Standards/regulations | EN 61000-4-2 |
| Contact discharge | 8 kV (Test Level 4) |
| Discharge in air | 15 kV (Test Level 4) |
| Comments | Criterion B |
Electromagnetic HF field
| Standards/regulations | EN 61000-4-3 |
| Frequency Range | 80 MHz ... 1 GHz |
| Test field strength | 20 V/m (Test Level 3) |
| Frequency Range | 1 GHz ... 2 GHz |
| Test field strength | 10 V/m (Test Level 3) |
| Frequency Range | 2 GHz ... 3 GHz |
| Test field strength | 10 V/m (Test Level 3) |
| Comments | Criterion A |
Fast transients (burst)
| Standards/regulations | EN 61000-4-4 |
| Input | 2 kV (Test Level 3 - asymmetrical) |
| Output | 2 kV (Test Level 3 - asymmetrical) |
| Signal | 2 kV (Test Level 4 - asymmetrical) |
| Comments | Criterion B |
Surge voltage load (surge)
| Standards/regulations | EN 61000-4-5 |
| Input | 0.5 kV (Test Level 1 - symmetrical) |
| Input | 0.5 kV (Test Level 1 - asymmetrical) |
| Output | 0.5 kV (Test Level 1 - symmetrical) |
| Output | 0.5 kV (Test Level 1 - asymmetrical) |
| Signal | 1 kV (Test Level 2 - asymmetrical) |
| Comments | Criterion B |
Conducted interference
| Standards/regulations | EN 61000-4-6 |
| I/O/S | asymmetrical |
| Frequency Range | 0.15 MHz ... 80 MHz |
| Comments | Criterion A |
| Voltage | 10 V (Test Level 3) |
Emitted interference
| Standards/regulations | EN 61000-6-3 |
| Radio interference voltage in acc. with EN 55011 | EN 55011 (EN 55022) Class B, area of application: Industry and residential |
| Emitted radio interference in acc. with EN 55011 | EN 55011 (EN 55022) Class B, area of application: Industry and residential |
Criteria
| Criterion A | Normal operating behavior within the specified limits. |
| Criterion B | Temporary impairment to operational behavior that is corrected by the device itself. |
Accessories
Why Proax for Phoenix Contact 2902879?
Proax is an authorized distributor of Phoenix Contact 2902879 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
| Pack Size | 1 |
Recommended