Series ELR-H

ELR H3-ES-SC-230AC/500AC-0,6 - Hybrid motor starter

Hybrid motor starter for starting 3~ AC motors up to 550 V AC, with 230 V AC input, 0.6 A output current, and emergency stop function.

  • 22.5 mm wide
  • Safety level in accordance with IEC 61508-1: SIL 3, ISO 13849: PL e
  • Reduction in wiring
  • Long service life
  • Space saving
  • 3-phase loop bridges
  • Low-wear switching
Technical Specifications

Product properties

Product familyCONTACTRON
Operating mode100% operating factor

Insulation characteristics: Air clearances and creepage distances between the power circuits

Insulationsafe isolation

Electrical properties

Number of phases3
Service life electrical3x 107 cycles
Reversing frequency≤ 2 Hz
Maximum power dissipation2.9 W
Minimum power dissipation2.6 W
Coordination type1

Air clearances and creepage distances between the power circuits

Rated Insulation Voltage500 V
Rated surge voltage6 kV

Supply

Rated control circuit supply voltage US230 V AC
Control supply voltage range92 V AC ... 253 V AC
Rated control supply current IS4 mA
Mains frequency50/60 Hz
Protective circuitSurge protection

Control

Rated actuating voltage UC230 V AC
Triggering voltage range92 V AC ... 253 V AC
Mains frequency50 Hz 60 Hz 50/60 Hz
Switching threshold44 V AC (“0” signal)
Switching threshold85 V AC (“1” signal)
Switching level< 5 V AC (For EMERGENCY STOP)
Typical turn-off time< 70 ms

AC output

Rated operating voltage Ue500 V AC
Operating voltage range42 V AC ... 550 V AC
Rated operating current Ie0.6 A (AC-51)
Rated operating current Ie0.6 A (AC-53a)
Mains frequency50/60 Hz
Load current range75 mA ... 600 mA (see to derating)
Trigger characteristic in acc. with IEC 60947-4-2Class 10A
Cooling time20 min. (for auto reset)
Leakage current0 mA
Residual voltage< 0.2 V
Protective circuitSurge protection

Acknowledge output

NoteConfirmation 01: floating changeover contact

Control circuits

Connection MethodScrew connection
Stripping length8 mm
Screw threadM3
Conductor cross section rigid0.2 mm² ... 2.5 mm²
Conductor cross section flexible0.2 mm² ... 2.5 mm²
Conductor cross section AWG24 ... 14

Load circuit

Connection MethodScrew connection
Stripping length8 mm
Screw threadM3
Conductor cross section rigid0.2 mm² ... 2.5 mm²
Conductor cross section flexible0.2 mm² ... 2.5 mm²
Conductor cross section AWG24 ... 14

Signaling

Status displayYellow LED
Operating voltage displayGreen LED
Error indicationRed LED

Dimensions

Width22.5 mm
Height107 mm
Depth114 mm

Material specifications

Flammability rating according to UL 94V0 (Housing)

Ambient conditions

Degree of ProtectionIP20
Ambient Temperature (Operation)-25 °C ... 70 °C
Ambient temperature (storage/transport)-40 °C ... 80 °C

UL data

SCCR100 kA (480 V AC (fuse: 30 A class CC/30 A class J (high fault)))
SCCR5 kA (480 V AC (fuse: 20 A RK5 (standard fault)))
FLA0.6 A (480 V)

Standards/regulations

Standards/regulationsDIN EN 50178
Standards/regulationsEN 60947

Power station requirements

Standards/regulationsDWR 1300/ZXX01/DD/7080.8d

Air clearances and creepage distances between the power circuits

Standards/regulationsDIN EN 50178

Mounting

Assembly instructionsCan be aligned with spacing = 20 mm
Mounting PositionVertical (horizontal DIN rail)

Why Proax for Phoenix Contact 2900686?

Proax is an authorized distributor of Phoenix Contact 2900686 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Pack Size1
Recommended

Available for order

Phoenix Contact Availability