OTDC100U11 PV Disconnect Switch, Terminal bolt kit included, Handle and shaft need to be ordered separately, Base mounting, UL 1000 VDC 100 A, IEC 1000 VDC 160 A
Technical Specifications

ABB EcoSolutions

ABB EcoSolutionsYes
ABB Site Meeting Group Waste To Landfill TargetUL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions1SCC301114M0201
Environmental InformationNA
Environmental Product Declaration - EPD1SCC301248D0201
Improved Energy Efficiency for CustomersProduct Efficiency - Product considered more energy-efficient compared to similar product on market or older products from the same line
Recyclability Rate of the Product acc. to EN45555Design for Closing Resource Loops - Standard EN45555 - 66,5 %

Dimensions

Product Frame SizeS1.0
Product Net Width115.5 mm
Product Net Width4.5 in
Product Net Height176 mm
Product Net Height6.9 in
Product Net Depth / Length83.5 mm
Product Net Depth / Length3.3 in
Product Net Weight1.2 kg
Product Net Weight2.7 lb

Technical

Connection configurationSingle circuit 2a, 2b
Conventional Free-air Thermal Current (Ith)Θ = 40 °C 160 A
Conventional Thermal Current (Ithe)Fully Enclosed 160 A
Degree of ProtectionFront IP20
Handle TypeHandle and shaft not included
Mounting TypeBase mounting
Number of Circuits1
Number of Poles2P
Operating modeFront
Pollution degree3
Position of Line TerminalsTop In - Bottom Out
Position of Line TerminalsBottom In - Top Out
Positive Opening Operation Torque (Direct Opening Action)5 … 8 N·m
Power Lossat Rated Operating Conditions per Pole 4 W
Protection TypeCircuit breaker
Rated Impulse Withstand Voltage (Uimp)12 kV
Rated Insulation Voltage (Ui)1500 V
Rated Operational Current DC-21B (Ie)(1000 V) 160 A
Rated Operational Voltage1000 V
Rated Short-Circuit Making Capacity (Icm)(1000 V DC) 10 kA
Rated Short-time Withstand Current Low Voltage (Icw)(1000 V DC) 10 kA
Rated Short-time Withstand Current Low Voltage (Icw)for 1 s 5 kA
Rated Short-time Withstand Current Low Voltage (Icw)for 0.1 s 10 kA
Shaft Diameter6 mm
Shaft Diameter0.24 in
Special FunctionsNo
StandardsUL98B and IEC 60947-1, -3
Switches Operating MechanismMechanism Between the Poles
Switches Operating Mechanism11 (Between the Poles)
Terminal TypeLug terminals
Terminal Width19.5 mm
Terminal Width0.77 in
Tightening torqueCable Lug 15 … 22 N·m
Tightening torqueCable Lug 133 … 195 lbf·in
UtilizationPhotovoltaic
Utilization categorySwitching of resistive loads, including moderate overloads - occasional actuation (DC-21B)

Technical UL/CSA

Maximum Operating Voltage1000Vdc, UL 98B
Ampere Rating100A,1000Vdc,UL98B
Short-circuit current rating (SCCR)10 kA
Short-circuit current rating (SCCR)1000 V DC
Tightening torqueCable Lug 15 … 22 N·m
Tightening torqueCable Lug 133 … 195 lbf·in

Why Proax for ABB OTDC100U11?

Proax is an authorized distributor of ABB OTDC100U11 and one of ABB's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size1
Recommended

Not in stock

Request lead time or order—we'll ensure quick delivery

ABB Availability