ILB PB AI4 AO2 - I/O module

Inline Block IO analog input/output module, PROFIBUS, inputs: 0-20 mA, 4-20 mA, ±20 mA, 0-5 V, ±5 V,0-10 V, ±10 V, Pt 100, Pt 1000, Ni 1000..., outputs: 0-5 V, ±5 V, 0-10 V, ±10V, 0-20 mA, ±20 mA, 4-20 mA, 2, 3, 4-conductor connection

  • Difference measurement or resistance thermometer (RTD)
  • 2 analog outputs (shielded)
  • 4 analog inputs (shielded)
Technical Specifications

Dimensions

Width156 mm
Height141 mm
Depth57 mm

Utilization restriction

EMC noteEMC: class A product, see manufacturer's declaration in the download area

Material specifications

Colorgreen

Inline local bus

Connection MethodD-SUB-9 female connector
Transmission Speed9.6 kbps ... 12 Mbps
Transmission physicsCopper

Module

Input address area8 Byte
Output address area4 Byte

Analog: General

Input nameAnalog inputs
Description of the inputDifferential input, incl. sensor supply (24 V DC)
Number of Inputsmax. 4 (Differential inputs, voltage or current can be chosen separately)
A/D conversion timetyp. 180 µs
A/D converter resolution16 bit
Connection MethodSpring-cage connection
Connection technology2-, 3-, 4-conductor (shielded)
Current Input Signal0 mA ... 20 mA
Current Input Signal4 mA ... 20 mA
Current Input Signal-20 mA ... 20 mA
Input resistance current inputtyp. 107 Ω
Voltage input signal-5 V ... 5 V
Voltage input signal0 V ... 10 V
Voltage input signal-10 V ... 10 V
Input resistance of voltage inputtyp. 276 kΩ
Data formatsIB IL
Limit frequency (3 dB)120 Hz (default for 4.5 ms filter)
Limit frequency (3 dB)450 Hz (for 1.1 ms filter)
Measured value resolution16 bits (15 bits + sign bit)

Analog: Voltage inputs

Number of Inputs4 (differential inputs, voltage)
Voltage input signal0 V ... 5 V
Voltage input signal-5 V ... 5 V
Voltage input signal0 V ... 10 V
Voltage input signal-10 V ... 10 V
Protective circuitOverload protection, short-circuit protection of sensor supply

Analog:

Number of Inputs4 (Differential inputs, current)
Current Input Signal0 mA ... 20 mA
Current Input Signal4 mA ... 20 mA
Current Input Signal-20 mA ... 20 mA
Input resistance current inputtyp. 107 Ω
Protective circuitElectronic short-circuit protection

Analog

Input nameAnalog RTD inputs
Number of Inputs4
Sensor types (RTD) that can be usedPt 100, Pt 500, Pt 1000, Ni 100, Ni 1000, Ni 1000 L&G
Linear resistance measuring range0 Ω ... 3200 Ω
Linear resistance measuring range0 Ω ... 9500 Ω
Protective circuitOverload protection, short-circuit protection of sensor supply

Analog:

Output nameAnalog outputs
Connection MethodSpring-cage connection
Connection technology2-conductor (shielded)
Number of Outputs2
D/A conversion timetyp. 70 µs
D/A converter resolution16 bit
Protective circuitShort-circuit protection of outputs
Data formatsIB IL
Representation of output values16 bits (15 bits + sign)
Process data update17 ms
Current Output Signal0 mA ... 20 mA
Current Output Signal4 mA ... 20 mA
Current Output Signal-20 mA ... 20 mA
Load/Output Load Current Outputto 500 Ω
Voltage output signal0 V ... 5 V
Voltage output signal-5 V ... 5 V
Voltage output signal0 V ... 10 V
Voltage output signal-10 V ... 10 V
Load/output load voltage output> 2 kΩ

Product properties

Product familyInline
TypeBlock design
TypeInline

Potentials: Communications power (UL)

Supply Voltage24 V DC
Supply Voltage Range19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Current drawmax. 150 mA (AO-I nominal load)
Current drawtyp. 100 mA
Supply Voltage24 V DC
Supply Voltage Range19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Current drawmax. 220 mA (maximum full load)

Potentials

Supply Voltage24 V DC
Current drawmax. 220 mA (maximum full load)

Connection technology

Connection nameInline connector

Conductor connection

Connection MethodSpring-cage connection
Conductor cross section rigid0.08 mm² ... 1.5 mm²
Conductor cross section flexible0.08 mm² ... 1.5 mm²
Conductor cross section AWG28 ... 16
Stripping length8 mm

Inline connector

Connection MethodSpring-cage connection
Conductor cross section, rigid0.08 mm² ... 1.5 mm²
Conductor cross section, flexible0.08 mm² ... 1.5 mm²
Conductor cross section AWG28 ... 16
Stripping length8 mm

Ambient conditions

Ambient Temperature (Operation)-25 °C ... 60 °C
Degree of ProtectionIP20
Air pressure (operation)80 kPa ... 108 kPa (up to 2000 m above sea level)
Air pressure (storage/transport)66 kPa ... 108 kPa (up to 3500 m above sea level)
Ambient temperature (storage/transport)-25 °C ... 85 °C
Permissible humidity (operation)10 % ... 85 % (non-condensing)
Permissible humidity (storage/transport)10 % ... 95 % (non-condensing)

Standards and Regulations

Protection classIII (IEC 61140, EN 61140, VDE 0140-1)

Mounting

Mounting TypeDIN rail mounting

Why Proax for Phoenix Contact 2878874?

Proax is an authorized distributor of Phoenix Contact 2878874 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size1
Recommended

Not in stock

Request lead time or order—we'll ensure quick delivery

Phoenix Contact Availability