2900068
SKU
PHX2900068
MPN
UM- D37SUB/M/HC3/16DO/MR/MT
Weight
0.777 kg
Series UM-D
UM- D37SUB/M/HC3/16DO/MR/MT - Active module
16-channel relay module (1 changeover contact) for Honeywell C300 output modules. On the control side, the module is controlled via D-SUB 37-pos. or FLK 50-pos. A screw connection with knife disconnection is available on the field side.
Technical Specifications
Product properties
| No. of channels | 16 |
| Operating mode | 100% operating factor |
| Mechanical service life | 2x 10⁷ cycles |
Insulation characteristics
| Insulation | Reinforced insulation |
Insulation characteristics: Air clearances and creepage distances, input/output
| Insulation | Reinforced insulation |
| Overvoltage category | III |
| Pollution degree | 2 |
Insulation characteristics: Air and creepage distances, output/output
| Insulation | Basic insulation |
| Overvoltage category | III |
| Pollution degree | 2 |
Air clearances and creepage distances, input/output
| Rated Insulation Voltage | 300 V |
| Rated surge voltage | 6 kV (1.2/50 μs) |
Air and creepage distances, output/output
| Rated Insulation Voltage | 300 V |
| Rated surge voltage | 4 kV (1.2/50 μs) |
Supported controller HONEYWELL Experion PKS C300/C-Series
| Suitable I/O card | TDOB01 (non-redundant) |
| Suitable I/O card | TDOB11 (redundant) |
Input data
| Nominal input voltage UN | 24 V DC |
| Input voltage range in reference to UN | 0.85 ... 1.1 |
| Input voltage range | 20.4 V DC ... 26.4 V DC |
| Typical input current at UN | 9 mA |
| Typical response time | 5 ms |
| Typical release time | 7 ms |
| Protective circuit | Freewheeling diode |
| Status display/channel | Yellow LED |
Switching
| Contact switching type | 1 changeover contact |
| Type of switch contact | Single contact |
| Contact Material | AgSnO |
| Maximum Switching Voltage | 250 V AC/DC |
| Minimum Switching Voltage | 12 V AC/DC |
| Limiting Continuous Current | 4 A (see derating curve) |
| Min. switching current | 10 mA |
| Interrupting rating (ohmic load) max. | 96 W (at 24 V DC) |
| Interrupting rating (ohmic load) max. | 20 W (at 48 V DC) |
| Interrupting rating (ohmic load) max. | 18 W (at 60 V DC) |
| Interrupting rating (ohmic load) max. | 23 W (at 110 V DC) |
| Interrupting rating (ohmic load) max. | 40 W (at 220 V DC) |
| Interrupting rating (ohmic load) max. | 1000 VA (for 250 V AC) |
Controller level
| Connection Method | D-SUB pin strip |
| Number of Connections | 1 |
| Number of Positions | 37 |
Field level
| Connection Method | Screw connection with disconnect knife |
| Stripping length | 8 mm |
| Screw thread | M3 |
| Conductor cross section rigid | 0.2 mm² ... 4 mm² |
| Conductor cross section flexible | 0.2 mm² ... 2.5 mm² |
| Conductor cross section AWG | 24 ... 12 |
Control side
| Connection Method | Flat-ribbon cable connector in acc. with IEC 60603-13 |
| Number of Connections | 1 |
| Number of Positions | 50 |
Signaling
| Status display present | Yes |
Dimensions
| Width | 259 mm |
| Height | 126 mm |
| Depth | 66 mm |
Ambient conditions
| Degree of Protection | IP00 |
| Degree of protection (Installation location) | ≥ IP54 (Installation location) |
| Ambient Temperature (Operation) | -15 °C ... 50 °C |
| Ambient temperature (storage/transport) | -15 °C ... 50 °C |
| Altitude | ≤ 2000 m |
Air clearances and creepage distances, input/output
| Standards/regulations | EN 61010-2-201 |
Air and creepage distances, output/output
| Standards/regulations | EN 61010-2-201 |
Mounting
| Mounting Type | DIN rail mounting |
| Assembly instructions | in rows with zero spacing |
| Mounting Position | any |
Notes
| Notes on operation | Do not connect adjacent channels to SELV/ PELV and voltages dangerous to the touch. |
| Notes on operation | The outputs are not suitable for switching different outer conductors. |
| Notes on operation | Against adjacent modules in the support rail direction at least one functional insulation on the output-side is complied with. If the application has higher requirements on the insulation (basic insulation or reinforced insulation), then these must be realized through suitable measures (e. g. partition plates). |
| Notes on operation | For proper use, the specifications of the installation directive (see Downloads) must be observed. For applications or use with third-party products, the specifications, and the safety and warning instructions of the respective third-party manufacturer must also be met. |
Why Proax for Phoenix Contact 2900068?
Proax is an authorized distributor of Phoenix Contact 2900068 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
| Pack Size | 1 |
Recommended