Official Distributor
SKU
MPN
CUC-IND-C1ZNI-S/R4QV6
Weight
0.028 kg
Series CUC-IND-C1ZNI
CUC-IND-C1ZNI-S/R4QV6 - RJ45 connector
RJ45 connector, design: RJ45, degree of protection: IP20, number of positions: 6, 100 Mbps, CAT5, material: Metal, connection method: Insulation displacement connection, connection cross section: AWG 26- 24, cable outlet: straight, High degree of resistance to vibration; 360° shielding; one-piece design; special tool-free assembly, VARAN
- Easy and time-saving assembly with IDC fast connection technology
- Can be used internationally due to EAC, UL 1863, and CAN/CSA C22.2
- Ideal companion for servicing or repairs in the field: no special tools required for mounting
Technical Specifications
Product properties
Type | RJ45 |
Sensor Type | VARAN |
Number of Positions | 6 |
Connection profile | RJ45 |
No. of cable outlets | 1 |
Type | RJ45 |
Shielded | no |
Cable outlet | straight |
Positions/contacts | 8P6C |
Insulation characteristics
Overvoltage category | I |
Degree of pollution | 2 |
Electrical properties
Rated voltage (III/3) | 72 V (DC) |
Rated current | 1.75 A |
Contact resistance | < 20 mΩ (Contact) |
Contact resistance | < 100 mΩ (shield) |
Frequency Range | to 100 MHz |
Insulation resistance | > 500 MΩ |
Nominal voltage UN | 48 V |
Nominal current IN | 1.75 A |
Contact resistance per contact pair | < 20 Ω |
Contact resistance | > 10 mΩ (Wire – IDC) |
Transmission medium | Copper |
Transmission characteristics (category) | CAT5 |
Transmission Speed | 100 Mbps |
Connection technology
Connection Method | Insulation displacement connection |
Connection cross section AWG | 4x 26 ... 24 (Data (solid and stranded)) |
Connection cross section AWG | 2x 26 ... 24 (Power (solid and stranded)) |
Conductor Cross Section | 4x 0.25 mm² ... 0.34 mm² (Data (solid and stranded)) |
Conductor Cross Section | 2x 0.32 mm² (Power (solid and stranded)) |
Cable outlet, angle | 180 |
Dimensions
Width | 13.65 mm |
Height | 14.4 mm |
Length | 53 mm |
Material specifications
Material | Plastic |
Flammability rating according to UL 94 | V0 |
Housing Material | Metal |
Housing surface material | Ni |
Cable seal material | NBR |
Contact Material | CuSn |
Contact surface material | Au/Ni |
Contact carrier material | PC |
Locking latch material | Stainless steel |
Material for screw connection | PA |
Cable/line
External Cable Diameter | 5 mm ... 9 mm |
External Cable Diameter | 5 mm ... 9 mm |
Wire diameter including insulation | ≤ 1.6 mm |
Cable cross section | 0.25 mm² |
Test voltage Core/Core | 1000 V |
Test voltage Core/Shield | 1500.00 V |
Mechanical data
Insertion/withdrawal cycles | ≥ 750 |
Insertion force per signal contact | < 20.00 N |
Extraction force per signal contact | < 20 N |
Test specification
Type of test | Vibration test |
Specification | IEC 60068-2-6 |
Frequency | 2-2000 Hz |
Sweep speed | 1 octave/min |
Amplitude | 1.00 mm |
Acceleration | 200.00 m/s² |
Test duration | 20.00 s |
Type of test | Shock testing |
Specification | IEC 60068-2-27 |
Acceleration | 491.00 m/s² |
Number of shocks per direction | 5.00 |
Ambient conditions
Degree of Protection | IP20 |
Ambient Temperature (Operation) | -40 °C ... 70 °C |
Ambient temperature (storage/transport) | -40 °C ... 70 °C |
Mounting
Mounting Type | For field assembly |
Accessories
Why Proax for Phoenix Contact 1406335?
Proax is an authorized distributor of Phoenix Contact 1406335 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size | 1 |