Proax

Currency
0 Items
proax logo
Cart
Phoenix ContactOfficial Distributor

By Phoenix Contact

SKU
MPN
2861755
Weight
0.178 kg
This product is Not Cancellable/Not Returnable

IB IL INC-IN-PAC - Function module

Inline, Position detection terminal, Incremental encoder input: 1, Symmetrical and asymmetrical encoders, Digital inputs: 3, 24 V DC, Digital outputs: 1, 0.5 A, transmission speed in the local bus: 500 kbps, degree of protection: IP20, including Inline connectors and marking fields

  • Supports incremental encoders with symmetrical signals in accordance with EIA standard RS-422 (line driver)
  • Supports incremental encoder with asymmetrical signals (push-pull)
  • Supplies encoder with 5 V or 24 V voltage
  • Three digital inputs for connecting two limit switches or a home position switch
  • Maximum input frequency of 300 kHz
  • 25-bit actual position value
  • Precise evaluation via 1x, 2x, or 4x sampling
  • Direction of rotation indicator via LED
Technical Specifications

Dimensions

Width24.4 mm
Height140.5 mm
Depth71.5 mm

Utilization restriction

CCCex noteUse in potentially explosive areas is not permitted in China.

Inline local bus

Number of interfaces2
Connection MethodInline data jumper
Transmission Speed500 kbps
Transmission physicsCopper

Module

ID code (dec.)127
ID code (hex)7F
Length code (hex)02
Length code (dec)02
Process data channel32 bit
Input address area4 Byte
Output address area4 Byte
Register length4 Byte
Required parameter data 1 Byte
Required configuration data 5 Byte

Digital:

Input nameDigital inputs
Description of the inputEN 61131-2 type 1
Number of Inputs3
Connection MethodSpring-cage connection
Connection technology3-conductor
Input voltage range "0" signal-3 V DC ... 5 V DC
Input voltage range "1" signal15 V DC ... 30 V DC
Nominal input voltage UIN24 V DC
Nominal input current at UINtyp. 2.7 mA

Encoder

Number of Inputs1 (Symmetrical or asymmetrical)
Input nameIncremental encoder input
Encoder signalsSymmetrical and asymmetrical encoders
Cable Lengthmax. 30 m (shielded cable, to ensure conformance with EMC Directive)

Digital:

Output nameDigital outputs
Connection MethodSpring-cage connection
Connection technology2-conductor
Number of Outputs1 (NPN, double assignment of input E3)

Product properties

Product familyInline
Typemodular
Scope of deliveryincluding Inline connectors and marking fields
Operating modeProcess data mode with two words

Insulation characteristics

Overvoltage categoryII (IEC 60664-1, EN 60664-1)
Pollution degree2 (IEC 60664-1, EN 60664-1)

Encoder

Number1
Nominal Output Voltage5 V DC
Voltage range4.75 V DC ... 5.25 V DC
Current carrying capacitymax. 250 mA
Protective circuitShort-circuit protection; Electrical and thermal
Number1
Nominal Output Voltage24 V DC
Voltage range19.2 V DC ... 30 V DC
Current carrying capacitymax. 250 mA
Protective circuitShort-circuit protection; Electronic and thermal
Numbermax. 1 (A, /A, B, /B, Z, /Z)
DesignationSymmetrical incremental encoders
Encoder supply voltage5 V DC
Encoder supply voltage24 V DC
Signal voltage levelDifferential signal (signal – inverted signal) ±0.5 V, minimum; ±6 V, maximum
Common mode voltage range signal - ground-10 V DC ... 13.2 V DC
Input Frequencymax. 300 kHz
Numbermax. 1 (A, B, (Z))
DesignationAsymmetrical incremental encoder
Encoder supply voltage5 V DC
Encoder supply voltage24 V DC
Signal voltage levelLow ≤ 2.5 V, high ≥ 3.5 V (up to 27 V, maximum)
Input Frequencymax. 300 kHz

Potentials: Communications power (UL)

Supply Voltage7.5 V DC (via voltage jumper)
Current drawmax. 70 mA
Power consumptionmax. 525 mW

Potentials: Main circuit supply (UM)

Supply Voltage24 V DC (via voltage jumper)
Supply Voltage Range19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Current drawmax. 1 A
Current drawtyp. 340 mA

Electrical isolation/isolation of the voltage ranges

Test voltage: 7.5 V supply (bus logics)/24 V supply (I/O)500 V AC, 50 Hz, 1 min.
Test voltage: 24 V supply (I/O) / functional ground500 V AC, 50 Hz, 1 min.
Test voltage: 7.5 V supply (bus logic)/functional ground500 V AC, 50 Hz, 500 min.

Connection technology

Connection nameInline connector

Conductor connection

Connection MethodSpring-cage connection
Conductor cross section rigid0.08 mm² ... 1.5 mm²
Conductor cross section flexible0.08 mm² ... 1.5 mm²
Conductor cross section AWG28 ... 16
Stripping length8 mm

Inline connector

Connection MethodSpring-cage connection
Conductor cross section, rigid0.08 mm² ... 1.5 mm²
Conductor cross section, flexible0.08 mm² ... 1.5 mm²
Conductor cross section AWG28 ... 16
Stripping length8 mm

Ambient conditions

Ambient Temperature (Operation)-25 °C ... 55 °C
Degree of ProtectionIP20
Air pressure (operation)70 kPa ... 106 kPa (up to 3000 m above sea level)
Air pressure (storage/transport)70 kPa ... 106 kPa (up to 3000 m above sea level)
Ambient temperature (storage/transport)-25 °C ... 85 °C
Permissible humidity (operation)10 % ... 95 % (non-condensing)
Permissible humidity (storage/transport)10 % ... 95 % (non-condensing)

Standards and Regulations

Protection classIII (IEC 61140, EN 61140, VDE 0140-1)

Mounting

Mounting TypeDIN rail mounting
Accessories

Why Proax for Phoenix Contact IB IL INC-IN-PAC?

Proax is an authorized distributor of Phoenix Contact IB IL INC-IN-PAC and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Alternate NamesIBILINCINPAC
Pack Size1
Recommended

Available for order