Proax

Currency
0 Items
proax logo
Cart
Phoenix ContactOfficial Distributor

By Phoenix Contact

SKU
MPN
IB IL 24 DO 8-2A-PAC
Weight
0.206 kg
This product is Not Cancellable/Not Returnable
Series IB-IL

IB IL 24 DO 8-2A-PAC - Digital module

Inline, Digital output terminal, Digital outputs: 8, 24 V DC, 2 A, connection technology: 4-conductor, transmission speed in the local bus: 500 kbps, degree of protection: IP20, including Inline connectors and marking fields

  • 8 digital outputs
  • Connection of actuators in 2-, 3-, and 4-conductor technology
  • Nominal current per output: 2 A
  • Total current of the terminal: 8 A
  • Short-circuit and overload-protected outputs
  • Diagnostic and status indicators
  • Approved for use in a safety-related segment circuit (refer to the information in the data sheet)
Technical Specifications

Dimensions

Width48.8 mm
Height119.8 mm
Depth71.5 mm
Note on dimensionsHousing dimensions

Inline local bus

Number of interfaces2
Connection MethodInline data jumper
Transmission Speed500 kbps

Module

ID code (dec.)189
ID code (hex)BD
Length code (hex)81
Length code (dec)129
Process data channel8 bit
Input address area0 Byte
Output address area1 Byte
Register length8 bit
Required parameter data 3 Byte
Required configuration data 4 Byte

Digital:

Output nameDigital outputs
Connection MethodSpring-cage connection
Connection technology4-conductor
Number of Outputs8
Protective circuitOverload protection, short-circuit protection of outputs
Output Voltage24 V DC (US - 1 V)
Output Currentmax. 2 A (per channel)
Output Currentmax. 8 A (per device, at 50% simultaneity)
Maximum Output Current per channel2 A
Maximum Output Current per module8 A (with 50% simultaneity)
Nominal Output Voltage24 V DC
Output voltage when switched offmax. 1 V (at 1 MΩ)
Output current when switched offmax. 1 µA
Nominal load, inductive48 VA (1,2 H, 12 Ω)
Nominal load, lamp48 W
Nominal load, ohmic48 W
Maximum operating frequency with ohmic nominal load500 Hz (this switching frequency is limited by the data rate selected, the number of bus devices, the structure of the bus, the software used and the control or computer system used)
Reverse voltage resistance to short pulsesReverse voltage proof
Behavior with overloadAuto restart
Behavior with inductive overloadOutput can be destroyed
Behavior at voltage switch-offThe output follows the power supply without delay
Overcurrent shut-downmin. 3 A
Output current with ground connection interrupt when switched offmax. 1 µA

Product properties

Product familyInline
Typemodular
Scope of deliveryincluding Inline connectors and marking fields
No. of channels8
Operating modeProcess data mode with one byte
Diagnostics messagesShort-circuit or overload of the digital outputs Error message in the diagnostic code (bus) and display (2 Hz) via the LED (D) on the module

Insulation characteristics

Overvoltage categoryII (IEC 60664-1, EN 60664-1)
Pollution degree2 (IEC 60664-1, EN 60664-1)

Electrical properties

Maximum power dissipation for nominal condition2.7 W

Potentials: Communications power (UL)

Supply Voltage7.5 V DC (via voltage jumper)
Current drawmax. 60 mA
Power consumptionmax. 0.45 W

Potentials: Segment circuit supply (US)

Supply Voltage24 V DC (via voltage jumper)
Supply Voltage Range19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Current drawmax. 8 A

Electrical isolation/isolation of the voltage ranges

Test voltage: 5 V supply, incoming remote bus/7.5 V supply (bus logics)500 V AC, 50 Hz, 1 min.
Test voltage: 5 V supply, outgoing remote bus/7.5 V supply (bus logics)500 V AC, 50 Hz, 1 min.
Test voltage: 7.5 V supply (bus logics)/24 V supply (I/O)500 V AC, 50 Hz, 1 min.
Test voltage: 24 V supply (I/O) / functional ground500 V AC, 50 Hz, 1 min.

Connection technology

Connection nameInline connector

Conductor connection

Connection MethodSpring-cage connection
Conductor cross section rigid0.08 mm² ... 1.5 mm²
Conductor cross section flexible0.08 mm² ... 1.5 mm²
Conductor cross section AWG28 ... 16
Stripping length8 mm

Inline connector

Connection MethodSpring-cage connection
Conductor cross section, rigid0.08 mm² ... 1.5 mm²
Conductor cross section, flexible0.08 mm² ... 1.5 mm²
Conductor cross section AWG28 ... 16
Stripping length8 mm

Ambient conditions

Ambient Temperature (Operation)-25 °C ... 55 °C
Degree of ProtectionIP20
Air pressure (operation)70 kPa ... 106 kPa (up to 3000 m above sea level)
Air pressure (storage/transport)70 kPa ... 106 kPa (up to 3000 m above sea level)
Ambient temperature (storage/transport)-25 °C ... 85 °C
Permissible humidity (operation)10 % ... 95 % (according to DIN EN 61131-2)
Permissible humidity (storage/transport)10 % ... 95 % (according to DIN EN 61131-2)

Standards and Regulations

Protection classIII (IEC 61140, EN 61140, VDE 0140-1)

Mounting

Mounting TypeDIN rail mounting
Accessories

Why Proax for Phoenix Contact 2861603?

Proax is an authorized distributor of Phoenix Contact 2861603 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Pack Size1
Recommended

Not in stock

Request lead time or order—we'll ensure quick delivery

Phoenix Contact Availability