Surge protection device - TT-EX(I)- 24DC

Terminal block with three-stage surge protection for a floating Ex-i signal circuit, separate PE connection, nominal voltage: 24 V DC, for mounting on NS 35/7.5, terminal block width: 6.2 mm, terminal block height: 54.6 mm. HART-compatible

  • Versions with and without disconnect knife
  • To terminate a row of TERMITRAB TT... devices, covers are available in the corresponding colors
  • Other voltage levels available on request
  • Protection of a floating double wire in intrinsically safe circuits
  • Multi-stage modular terminal blocks with screw connection technology
  • Disconnection of signal circuits by disconnect knife
Technical Specifications

Dimensions

Height79.6 mm
Width6.2 mm
Depth54.6 mm

Ambient conditions

Ambient Temperature (Operation)-40 °C ... 80 °C
Altitude≤ 2000 m (amsl (above mean sea level))
Degree of ProtectionIP20 (with end cover)

General

Housing MaterialPA 6.6
Flammability rating according to UL 94V-0
Colorsky blue RAL 5015
Standards for cearances and creepage distancesEN 60079-11
Mounting TypeDIN rail: 35 mm
TypeDouble-level terminal block with PE foot – separate PE connection
Direction of actionLine-Line & Line-Earth Ground

Protective circuit

IEC test classificationC1
IEC test classificationC2
IEC test classificationC3
IEC test classificationD1
Nominal voltage UN24 V DC
Maximum continuous voltage UC30 V DC
Maximum continuous voltage UC21 V AC
Rated current250 mA (40 °C)
Operating effective current IC at UC≤ 5 µA
Residual current IPE≤ 1 µA
Nominal discharge current In (8/20) µs (line-line)5 kA
Nominal discharge current In (8/20) µs (line-earth)5 kA
Pulse discharge current Iimp (10/350) µs (line-earth)500 A
Total discharge current Itotal (8/20) µs10 kA
Nominal pulse current Ian (10/1000) µs (line-line)100 A
Nominal pulse current Ian (10/1000) µs (line-earth)100 A
Output voltage limitation at 1 kV/µs (line-line) spike≤ 50 V
Output voltage limitation at 1 kV/µs (line-earth) spike≤ 1.7 kV
Output voltage limitation at 1 kV/µs (line-line) static≤ 50 V
Output voltage limitation at 1 kV/µs (line-earth) static≤ 1.7 kV
Voltage protection level Up (line-line)≤ 55 V (C1 - 1 kV / 500 A)
Voltage protection level Up (line-line)≤ 75 V (C2 - 10 kV / 5 kA)
Voltage protection level Up (line-line)≤ 50 V (C3 - 10 A)
Voltage protection level Up (line-line)≤ 50 V (C3 - 100 A)
Voltage protection level Up (line-earth)≤ 2.2 kV (C2 - 10 kV / 5 kA)
Voltage protection level Up (line-earth)≤ 1.5 kV (C3 - 10 A)
Voltage protection level Up (line-earth)≤ 2 kV (C3 - 100 A)
Voltage protection level Up (line-earth)≤ 2 kV (D1 - 500 A)
Response time tA (line-line)≤ 1 ns
Response time tA (line-earth)≤ 100 ns
Input attenuation aE, sym.typ. 0.7 dB (≤ 400 kHz/50 Ω)
Input attenuation aE, sym.typ. 0.3 dB (≤ 200 kHz / 150 Ω)
Cut-off frequency fg (3 dB), sym. in 50 Ω systemtyp. 6 MHz
Cut-off frequency fg (3 dB), sym. in 150 Ω systemtyp. 2 MHz
Capacity (line-line)≤ 2 nF
Resistance per path4.7 Ω ±20 %
Surge protection fault messagenone
Max. required back-up fuse250 mA (T)
Impulse durability (line-line)C1 - 1 kV / 500 A
Impulse durability (line-line)C2 - 10 kV / 5 kA
Impulse durability (line-line)C3 - 100 A
Impulse durability (line-earth)C2 - 10 kV / 5 kA
Impulse durability (line-earth)C3 - 100 A
Impulse durability (line-earth)D1 - 500 A
Alternating current carrying capacity (line-earth)0.5 A - 1 s

Connection data

Connection MethodScrew terminal blocks
Screw threadM3
Tightening torque0.6 Nm
Stripping length8 mm
Conductor cross section flexible0.2 mm² ... 2.5 mm²
Conductor cross section solid0.2 mm² ... 4 mm²
Conductor cross section AWG24 ... 14

Standards and Regulations

Standards/specificationsEN 61643-21 2001 + A1:2009 + A2:2013
Standards/specificationsEN 60079-0 2012
Standards/specificationsEN 60079-11 2012
Standards/specificationsEN 60079-26 2007
Standards/specificationsIEC 60079-0 2011
Standards/specificationsIEC 60079-11 2011
Standards/specificationsIEC 60079-26 2006

Ex data

Maximum inner capacitance Ci2 nF
Max. internal inductance Li1 µH
Maximum inner time factor (Ri/Li)0.1 µs
Max. input current Ii250 mA (TA < 40 °C)
Max. input voltage Ui30 V DC
max. input power Pi0.75 W
Ambient Temperature (Operation)-40 °C ... 40 °C (T6 / 85 °C)
Ambient Temperature (Operation)-40 °C ... 50 °C (T5 / T 100 °C)
Ambient Temperature (Operation)-40 °C ... 80 °C (T4 / 135 °C)

Conformity / approvals

ATEX??? II 1G Ex ia IIC T4...T6 Ga
ATEX??? II 1D Ex ia IIIC T135°C...T85°C Da
IECExEx ia IIC T4...T6 Ga
IECExEx ia IIIC T135 °C...T85 °C Da

Environmental Product Compliance

REACh SVHCLead 7439-92-1
China RoHSEnvironmentally Friendly Use Period = 50 years
China RoHSFor details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Accessories

Why Proax for Phoenix Contact 2832124?

Proax is an authorized distributor of Phoenix Contact 2832124 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size10
Recommended

Price N/A

Sold in quantities of 10

Not in stock

Request lead time or order—we'll ensure quick delivery

Phoenix Contact Availability