SKU
MPN
MCR-S-1-5-UI-SW-DCI-NC
Weight
0.204 kg
This product is Not Cancellable/Not Returnable
Series MCR-S
MCR-S-1-5-UI-SW-DCI-NC - Current transducers
MCR current transducer, programmable and configurable, for measuring direct, alternating and distorted currents, with relay and transistor output, input current 0 ... 0.2 A to 0 ... 11 A, unconfigured
- Device can be set via DIP switches or MCR/PI-CONF-WIN configuration software
- 3-way isolation
- True r.m.s. value measurement
Technical Specifications
Utilization restriction
EMC note | EMC: class A product, see manufacturer's declaration in the download area |
Insulation characteristics
Overvoltage category | III |
Pollution degree | 2 |
Electrical properties
Total error | ≤ 1.5 % (Temperature range) |
Maximum power dissipation for nominal condition | 2.2 W |
Measuring category | III |
Test voltage output/power supply | 500 V AC (50 Hz, 60 s) |
Test voltage input/output | 4 kV AC (50 Hz, 60 s) |
Test voltage input/power supply | 4 kV AC (50 Hz, 60 s) |
Protective circuit | Surge protection; 33 V suppressor diode |
Step response (10-90%) | 330 ms (AC) |
Step response (10-90%) | 40 ms (DC) |
Temperature coefficient, typical | < 0.025 %/K |
Maximum transmission error | < 0.5 % (of nominal range value under nominal conditions) |
Rated Insulation Voltage | 300 V AC (to earth) |
Supply
Supply Voltage Range | 20 V DC ... 30 V DC |
Max. current consumption | < 50 mA (without load) |
Measurement
Number of Inputs | 3 |
Configurable/programmable | Yes, unconfigured |
Input current range | 0 A AC/DC ... 11 A AC/DC (Permitted continuous overload: 120%) |
Measuring Range | 0 A AC/DC ... 1 A AC/DC |
Measuring Range | 0 A AC/DC ... 5 A AC/DC |
Measuring Range | 0 A AC/DC ... 10 A AC/DC |
Setting range for min. input current | 0 mA AC/DC ... 200 mA AC/DC |
Setting range for max. input current | 0 A AC/DC ... 11 A AC/DC |
LSB: Current | 1 µA (1 A) |
LSB: Current | 2 µA (2 A) |
LSB: Current | 5 µA (5 A) |
LSB: Current | 10 µA (10 A) |
LSB: Current | 50 µA (50 A) |
LSB: Current | 100 µA (100 A) |
Overload capacity | 2 x IN (continuous) |
Surge strength | 20 x IN (1 s) |
Frequency measuring range | 15 Hz ... 400 Hz |
Curve type | AC, DC or distorted currents |
Operate threshold | 2 % (of measuring range nominal value 1/5/10 A) |
Switching: Relay
Contact switching type | 1 changeover contact |
Contact Material | AgSnO, hard gold-plated |
Maximum Switching Voltage | 30 V AC |
Maximum Switching Voltage | 36 V DC |
Maximum Switching Voltage | 250 V AC |
Limiting Continuous Current | 50 mA (for gold layer, 30 V AC/ 36 V DC) |
Limiting Continuous Current | 2 A (in case of a destroyed gold layer, 250 V AC) |
Switching: Transistor
Continuous load current | 80 mA (Not short-circuit proof) |
Output voltage range | 19 V ... 29 V (supply voltage - 1 V) |
Setting range of the threshold value | 1 % ... 110 % |
Setting range of the response delay | 0.1 s ... 20 s |
Status display | Yellow LED |
Signal: Voltage/current
Configurable/programmable | Yes, unconfigured |
Voltage output signal | 0 V ... 5 V |
Voltage output signal | 1 V ... 5 V |
Voltage output signal | 0 V ... 10 V |
Voltage output signal | 2 V ... 10 V |
Voltage output signal | -5 V ... 5 V |
Voltage output signal | -10 V ... 10 V |
Voltage output signal | 10 V ... 0 V |
Voltage output signal | 10 V ... 2 V |
Voltage output signal | 10 V ... -10 V |
Voltage output signal | 5 V ... 0 V |
Voltage output signal | 5 V ... 1 V |
Voltage output signal | 5 V ... -5 V |
Current Output Signal | 0 mA ... 20 mA |
Current Output Signal | 4 mA ... 20 mA |
Current Output Signal | 20 mA ... 0 mA |
Current Output Signal | 20 mA ... 4 mA |
Load/output load voltage output | > 10 kΩ |
Load/Output Load Current Output | < 500 Ω |
Connection data
Connection Method | Screw connection |
Stripping length | 8 mm |
Screw thread | M3 |
Conductor cross section rigid | 0.2 mm² ... 2.5 mm² |
Conductor cross section flexible | 0.2 mm² ... 2.5 mm² |
Conductor cross section AWG | 24 ... 14 |
Signaling
Status display | Green LED |
Item dimensions
Width | 22.5 mm |
Height | 99 mm |
Depth | 114.5 mm |
Material specifications
Color | green (RAL 6021) |
Housing Material | Polyamide PA non-reinforced |
Ambient conditions
Degree of Protection | IP20 |
Ambient Temperature (Operation) | -20 °C ... 60 °C |
Ambient temperature (storage/transport) | -40 °C ... 85 °C |
Altitude | < 2000 m |
Permissible humidity (operation) | 10 % ... 95 % (non-condensing) |
CE
Certificate | CE-compliant |
UL, USA/Canada
Identification | Class I, Zone 2, AEx nA nC IIC T4, Ex nA nC IIC T4 Gc X |
Identification | Class I, Div. 2, Groups A, B, C and D or Non-Hazardous Locations Only |
EMC data
Low Voltage Directive | Conformance with Low Voltage Directive |
Noise immunity | EN 61000-6-2 |
Electromagnetic compatibility | Conformance with EMC directive |
Noise emission | EN 61000-6-4 |
Standards and Regulations
Standards/regulations | IEC 61010-2-030 |
Mounting
Mounting Type | DIN rail mounting |
Mounting Position | any |
Accessories
Why Proax for Phoenix Contact 2814731?
Proax is an authorized distributor of Phoenix Contact 2814731 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size | 1 |