2809487
SKU
PHX2809487
MPN
C-UFB- 5DC/E-LAN
Weight
0.11 kg
Series C-UFB
C-UFB- 5DC/E-LAN - Surge protection device
Attachment plug with surge protection for LAN interfaces, connection: BNC socket/plug
Technical Specifications
Product properties
| IEC test classification | C2 |
| IEC test classification | C3 |
| IEC test classification | D1 |
| VDE requirement class | C2 |
| VDE requirement class | C3 |
| VDE requirement class | D1 |
| Type | Attachment plug |
| Number of Positions | 1 |
Connection data
| Connection Method | BNC 50 Ω |
Dimensions
| Width | 25.4 mm |
| Height | 25.4 mm |
| Depth | 93 mm |
Material specifications
| Housing Material | Aluminum |
Mechanical data
| Open side panel | No |
Protective circuit
| Direction of action | Line-Signal Ground/Shield & Signal Ground/Shield-Earth Ground |
| Maximum continuous voltage UC (line-line) | - 7.5 V DC (Line-shield) |
| Maximum continuous voltage UC (line-shield) | 0.5 V DC (7.5 V DC) |
| Operating effective current IC at UC | ≤ 100 µA |
| Residual current IPE | ≤ 1 µA |
| Nominal discharge current In (8/20) µs (line-ground) | 10 kA |
| Nominal discharge current In (8/20) µs (line-shield) | 10 kA |
| Nominal discharge current In (8/20) µs (shield-ground) | 10 kA |
| Total surge current (8/20) µs | 10 kA |
| Output voltage limitation at 1 kV/µs (line-earth) spike | ≤ 600 V |
| Output voltage limitation at 1 kV/µs (line-line) static | ≤ 12 V |
| Output voltage limitation at 1 kV/µs (line-earth) static | ≤ 600 V |
| Residual voltage at In (conductor-conductor) | ≤ 25 V |
| Residual voltage at In (conductor-ground) | ≤ 400 V |
| Voltage protection level Up (line-line) | ≤ 25 V (Line-shield) |
| Voltage protection level Up (line-earth) | ≤ 600 V |
| Response time tA (line-line) | ≤ 1 ns |
| Response time tA (line-earth) | ≤ 100 ns |
| Input attenuation aE, asym. | 0.3 dB (≤ 40 MHz / 50 Ω) |
| Cut-off frequency fg (3 dB), asym. (PE) in 100 Ω system | typ. 200 MHz (50 Ω / core shield) |
| Cut-off frequency fg (3 dB), asym. (shield) in 100 Ω system | typ. 200 MHz (50 Ω) |
| Capacity (line-signalground) | 25 pF (f =1 MHz / VR= 0 V) |
| Resistance per path | 2.35 Ω ±10 % |
| Impulse durability (line-line) | C2 - 10 kV / 5 kA |
| Impulse durability (line-earth) | C2 - 10 kV / 5 kA |
| Impulse durability (line-earth) | D1 - 2.5 kA |
Ambient conditions
| Degree of Protection | IP20 |
| Ambient Temperature (Operation) | -40 °C ... 80 °C |
Standards and Regulations
| VDE requirement class | C2 |
| VDE requirement class | C3 |
| VDE requirement class | D1 |
Air clearances and creepage distances
| Standards/regulations | VDE 0110-1 / IEC 60664-1 |
Standards Information technology specification
| Standards/regulations | IEC 61643-21 |
| Standards/regulations | IEC 61643-21 |
Mounting
| Mounting Type | Connection-specific intermediate plugging |
Why Proax for Phoenix Contact 2809487?
Proax is an authorized distributor of Phoenix Contact 2809487 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
| Pack Size | 10 |