CADEN
Cart

2803069

Official Distributor

By Phoenix Contact

SKU
PHX2803069
MPN
DT-UFB-V24/S-9-SB
Series DT-UFB-V24

DT-UFB-V24/S-9-SB - Surge protection device

Attachment plug with surge protection for V.24 interface. Connection: D-SUB-9 plug/socket, installation in lines

  • Easy network integration via D-SUB connection
  • No signal interference with adapted protective circuit
  • Can be installed in a control cabinet by removing the ground connection adapter
Technical Specifications

Product properties

Product familyDATATRAB
IEC test classificationB2
IEC test classificationC1
IEC test classificationC2
IEC test classificationC3
VDE requirement classB2
VDE requirement classC1
VDE requirement classC2
VDE requirement classC3
TypeAttachment plug for DIN rail mounting
Number of Positions9

Insulation characteristics

Overvoltage categoryII

Connection data

Connection MethodD-SUB-9

Dimensions

Width25 mm
Height102 mm
Depth63.5 mm

Material specifications

ColorSilver
Colorblack (RAL 9005)
Housing MaterialZinc die-cast

Mechanical data

Open side panelNo

Protective circuit

Direction of actionLine-Line & Line-Signal Ground/Shield & Signal Ground/Shield-Earth Ground
Maximum continuous voltage UC15 V DC
Maximum continuous voltage UC10 V AC
Rated current≤ 1 A (25 °C)
Operating effective current IC at UC≤ 5 µA (per wire)
Residual current IPE≤ 1 µA
Nominal discharge current In (8/20) µs (line-line)≤ 250 A
Nominal discharge current In (8/20) µs (line-ground)≤ 250 A
Nominal discharge current In (8/20) µs (line-signal ground)≤ 250 A
Nominal discharge current In (8/20) µs (signalground-earth)≤ 5 kA
Total discharge current Itotal (8/20) µs5 kA
Nominal pulse current Ian (10/1000) µs (line-line)50 A
Nominal pulse current Ian (10/1000) µs (line-earth)50 A
Nominal pulse current Ian (10/1000) µs (line-signalground)50 A
Nominal pulse current Ian (10/700) µs (line-line)50 A
Nominal pulse current Ian (10/700) µs (line-earth)50 A
Nominal pulse current Ian (10/700) µs (line-signalground)50 A
Output voltage limitation at 1 kV/µs (line-line) static≤ 50 V
Output voltage limitation at 1 kV/µs (line-signalground) static≤ 30 V
Residual voltage at In (conductor-conductor)≤ 55 V
Residual voltage at In (line-signalground)≤ 30 V
Voltage protection level Up (line-line)≤ 55 V (C1 - 250 A)
Voltage protection level Up (line-line)≤ 55 V (B2 - 25 A)
Voltage protection level Up (line-earth)≤ 450 V (C1 - 250 A)
Voltage protection level Up (line-earth)≤ 400 V (B2 - 25 A)
Voltage protection level Up (line-signalground)≤ 30 V (C1 - 250 A)
Voltage protection level Up (line-signalground)≤ 30 V (B2 - 25 A)
Response time tA (line-line)≤ 1 ns
Response time tA (line-earth)≤ 100 ns
Response time tA (line-signalground)≤ 1 ns
Response time tA (shield-ground)≤ 100 ns
Input attenuation aE, sym.typ. 0.3 dB (≤ 700 kHz / 100 Ω)
Input attenuation aE, sym.typ. 0.3 dB (≤ 700 kHz / 150 Ω)
Input attenuation aE, asym.typ. 0.3 dB (≤ 400 kHz / 100 Ω)
Input attenuation aE, asym.typ. 0.3 dB (≤ 400 kHz / 150 Ω)
Cut-off frequency fg (3 dB), sym. in 100 Ω systemtyp. 2.5 MHz
Cut-off frequency fg (3 dB), sym. in 150 Ω systemtyp. 2.5 MHz
Cut-off frequency fg (3 dB), asym. (signal ground) in 100 Ω systemtyp. 1.3 MHz
Cut-off frequency fg (3 dB), asym. (signal ground) in 150 Ω systemtyp. 1.3 MHz
Capacity (core-core)typ. 1 nF (f=1 MHz / VR= 0 V)
Capacity (line-signalground)typ. 2 nF (f=1 MHz / VR= 0 V)
Surge protection fault messagenone
Impulse durability (line-line)B2 - 1 kV / 25 A
Impulse durability (line-line)C1 - 500 V / 250 A
Impulse durability (line-signalground)B2 - 1 kV/25 A
Impulse durability (line-signalground)C1 - 500 V/250 A
Impulse durability (signalground-earth)B2 - 4 kV / 100 A
Impulse durability (signalground-earth)C1 - 100 V / 500 A
Impulse durability (signalground-earth)C2 - 10 kV/5 kA
Alternating current carrying capacity (signalground-earth)5 A - 1 s

Ambient conditions

Degree of ProtectionIP20
Ambient Temperature (Operation)-40 °C ... 85 °C

Standards and Regulations

VDE requirement classB2
VDE requirement classC1
VDE requirement classC2
VDE requirement classC3

Air clearances and creepage distances

Standards/regulationsIEC 60664-1 / VDE 0110-1

Standards Information technology specification

Standards/regulationsIEC 61643-21
Standards/regulationsIEC 61643-21
Standards/specificationsDIN EN 61643-21
Note2002
Standards/specificationsIEC 61643-21
Note2000

Mounting

Mounting TypeConnection-specific attachment plug and DIN rail, 35 mm
Accessories

Why Proax for Phoenix Contact 2803069?

Proax is an authorized distributor of Phoenix Contact 2803069 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size1
Recommended

CAD$393.17

Not in stock

Request lead time or order—we'll ensure quick delivery

Phoenix Contact Availability