SUBCON-PLUS-PROFIB/AX - D-SUB bus connector
D-SUB connector, 9-pos., male connector, axial version with two cable entries, bus system: PROFIBUS DP up to 12 Mbps, termination resistor can be switched on via slide switch, pin assignment: 3, 5, 6, 8; spring-cage connection terminal blocks
Technical Specifications
Utilization restriction
| CCCex note | Use in potentially explosive areas is not permitted in China. |
Product properties
| MTTF | 6706 Years (SN 29500 standard, temperature 25°C, operating cycle 21%) |
| MTTF | 1817 Years (SN 29500 standard, temperature 40°C, operating cycle 34.25%) |
| MTTF | 155 Years (SN 29500 standard, temperature 40°C, operating cycle 100%) |
| Pin assignment | 3, 5, 6, 8 |
Electrical properties
| Maximum power dissipation for nominal condition | 0.025 W |
| Nominal voltage UN | 5 V |
| Nominal current IN | 100 mA |
| Transmission medium | Copper |
Connection data
| Tightening torque | ... 0.4 Nm |
D-SUB connection
| Connection Method | D-SUB connector |
PCB connection
| Connection Method | Spring-cage connection |
| Stripping length | 9 mm |
| Conductor cross section, rigid min. | 0.12 mm² |
| Conductor cross section, rigid max. | 0.5 mm² |
| Single-wire/terminal point, rigid AWG min. | 26 |
| Single-wire/terminal point, rigid AWG max. | 20 |
Interfaces
| Bus system | PROFIBUS DP |
| Signal | PROFIBUS |
Dimensions
| Width | 17 mm |
| Height | 31.5 mm |
| Length | 58.2 mm |
Material specifications
| Material (Housing) | ABS (metal-plated) |
Cable/line
| External Cable Diameter | 7.6 mm ... 8.4 mm (Incoming bus line) |
Mechanical data
| Insertion/withdrawal cycles | > 200 |
Ambient conditions
| Degree of Protection | IP40 |
| Ambient Temperature (Operation) | -20 °C ... 75 °C |
| Ambient temperature (storage/transport) | -25 °C ... 80 °C |
| Altitude | ≤ 5000 m (For restrictions, see the manufacturer's declaration for altitude operation) |
| Permissible humidity (operation) | 10 % ... 95 % (non-condensing) |
| Permissible humidity (storage/transport) | 5 % ... 95 % (non-condensing) |
ATEX
| Identification | II 3 G Ex ec IIC T4 Gc |
| Certificate | PxCIF15ATEX2744348X |
| Note | Please follow the special installation instructions in the documentation! |
UKEX
| Identification | II 3 G Ex ec IIC T4 Gc |
| Certificate | PxCIMA22UKEX2744348X |
Corrosive gas test
| Identification | ISA-S71.04-1985 G3 Harsh Group A |
Standards and Regulations
| Free from substances that could impair the application of coating | in accordance with VW-AUDI-Seat central standard P-VW 3.10.7 57 65 0 |
Accessories
SUBCON-PLUS-PROFIB/PG/SC2 - D-SUB connector, 9-pos., male connector, 35° cable entry, bus system: PROFIBUS DP up to 12 Mbps with PG D-SUB socket for connecting a programming device, termination resistor can be switched on via slide switch, pin assignment: 3, 5, 6, 8; screw connection terminal blocks
SUBCON-PLUS-PROFIB/90/PG/IDC - D-SUB connector, 9-pos., male connector, 90° cable entry, bus system: PROFIBUS DP up to 12 Mbps with PG D-SUB socket for connecting a programming device, termination resistor can be switched on via slide switch, pin assignment: 3, 5, 6, 8; IDC terminal block connection
Why Proax for Phoenix Contact 2744377?
Proax is an authorized distributor of Phoenix Contact 2744377 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
| Pack Size | 1 |
Recommended
SUBCON-PLUS-PROFIB/90/PG/IDC - D-SUB connector, 9-pos., male connector, 90° cable entry, bus system: PROFIBUS DP up to 12 Mbps with PG D-SUB socket for connecting a programming device, termination resistor can be switched on via slide switch, pin assignment: 3, 5, 6, 8; IDC terminal block connection
SUBCON-PLUS-PROFIB/90/PG/SC - D-SUB connector, 9-pos., male connector, 90° cable entry, bus system: PROFIBUS DP up to 12 Mbps with PG D-SUB socket for connecting a programming device, termination resistor can be switched on via slide switch, pin assignment: 3, 5, 6, 8; screw connection terminal blocks
SUBCON-PLUS-PROFIB/PG - D-SUB connector, 9-pos., male connector, 35° cable entry, bus system: PROFIBUS DP up to 12 Mbps with Pg D-SUB socket for connecting a programming device, termination resistor can be switched on via slide switch, pin assignment: 3, 5, 6, 8; spring-cage connection terminal blocks
SUBCON-PLUS-PROFIB/PG/SC2 - D-SUB connector, 9-pos., male connector, 35° cable entry, bus system: PROFIBUS DP up to 12 Mbps with PG D-SUB socket for connecting a programming device, termination resistor can be switched on via slide switch, pin assignment: 3, 5, 6, 8; screw connection terminal blocks