PSI-GPRS/GSM-MODEM/RS232-QB - Modem
Industrial GPRS/GSM modem for mounting on EN DIN rails. GSM and GPRS. 850 + 900 + 1800 + 1900 MHz. Serial V.24 (RS-232) interface. TCP/IP stack. Alarm input and output. 24 V DC supply voltage.
- Fixed latency
- High electromagnetic compatibility
- Can be used worldwide
- Can be used regardless of controller manufacturer
- Firewall
- One switching output on backplane, can be activated via SMS with password protection
- Encryption of SIM card PINs
- Connection establishment with password protection
- GSM mobile phone network: 850, 900, 1800, and 1900 MHz
- IPT-compatible
- Integrated TCP/IP stack for integrating devices without a TCP/IP stack into a network
- Data rates of up to 53.6 kbps
- Connection establishment via data phone number (CSD)
- Client/server functionality
- Connection establishment via IP addresses
Technical Specifications
Utilization restriction
CCCex note | Use in potentially explosive areas is not permitted in China. |
Insulation characteristics
Degree of pollution | 2 |
Electrical properties
Electrical isolation | VCC // RS-232 // GSM |
Maximum power dissipation for nominal condition | 8.4 W |
Mains type | Cellular communication |
Test voltage data interface/power supply | 1.5 kV (50 Hz, 1 min.) |
Test voltage data interfaces | 1500 V |
Supply
Supply Voltage Range | 10 V DC ... 30 V DC (via pluggable COMBICON screw terminal block) |
Nominal Supply Voltage | 24 V DC ±5 % (as an alternative or redundant, via backplane bus contact and system current supply) |
Typical current consumption | < 350 mA (24 V DC) |
Typical current consumption | < 80 mA (stand by) |
Digital
Description of the input | Digital input |
Number of Inputs | 2 |
Voltage input signal | 9 V DC ... 60 V DC |
Current Input Signal | 5 mA |
Signal
Output name | Digital output |
Number of Outputs | 1 |
Voltage output signal | 10 V DC ... 30 V DC |
Current Output Signal | ≤ 80 mA (24 V) |
Supply
Tightening torque | 0.56 Nm ... 0.79 Nm |
Interfaces
Signal | RS-232 |
Data: V.24 (RS-232) interface in acc. with ITU-T V.28, EIA/TIA-232, DIN 66259-1
Transmission Speed | 1.2/2.4/9.6/19.2/38.4/57.6/115.2 kbps (can be set manually and automatically) |
Connection Method | D-SUB 9 plug |
Transmission length | 15 m |
File format/coding | Serial asynchronous UART/NRZ, 7/8 data, 1/2 stop, 1 parity, 10/11-bit character length |
Data flow control/protocols | Software handshake, Xon/Xoff or hardware handshake RTS/CTS |
Wireless
Interface description | GSM / GPRS |
Frequency Range | 850 MHz (2 W (EGSM)) |
Frequency Range | 900 MHz (2 W (EGSM)) |
Frequency Range | 1800 MHz (1 W (EGSM)) |
Frequency Range | 1900 MHz (1 W (EGSM)) |
Data rate | ≤ 85.6 kbps |
Antenna | 50 Ω impedance SMA antenna socket |
SIM Interface | 1.8 volt, 3 volt |
GSM | CSD 9.6/14.4 kbps |
GPRS | Class 10, Class B |
GPRS | CS1 ... CS4 |
Network function | 4 time slots for receiving data, 2 time slot for transmitting data. The PIN is saved in the modem. After a voltage interruption, there is automatic redialing into the network Integrated TCP/IP Stack, independent connection establishment. |
Network check | LED to show data signal quality |
Dimensions
Width | 22.5 mm |
Height | 99 mm |
Depth | 118.6 mm |
Material specifications
Material (Housing) | PA V0 |
Ambient conditions
Degree of Protection | IP20 |
Ambient Temperature (Operation) | -25 °C ... 60 °C |
Altitude | ≤ 5000 m (For restrictions, see the manufacturer's declaration for altitude operation) |
Altitude | ≤ 2000 m (in acc. with UL) |
CE
Certificate | CE-compliant |
UL, USA/Canada
Identification | 508 Listed |
Identification | Class I, Zone 2, AEx nA IIC T4 |
Identification | Class I, Zone 2, Ex nA IIC T4 Gc X |
Corrosive gas test
Identification | ISA-S71.04-1985 G3 Harsh Group A |
EMC data
Noise immunity | EN 61000-6-2:2005 |
Electromagnetic compatibility | Conformance with RED Directive 2014/53/EU |
Noise emission | EN 55032 |
Electrostatic discharge
Standards/regulations | EN 61000-4-2 |
Contact discharge | ± 6 kV (Test Level 3) |
Discharge in air | ± 8 kV (Test Level 3) |
Indirect discharge | ± 6 kV |
Comments | Criterion B |
Electromagnetic HF field
Standards/regulations | EN 61000-4-3 |
Frequency Range | Test Level 3 |
Field intensity | 10 V/m |
Comments | Criterion A |
Fast transients (burst)
Standards/regulations | EN 61000-4-4 |
Input | ± 2 kV (Test Level 3) |
Signal | ± 1 kV (Test Level 3) |
Comments | Criterion B |
Surge current load (surge)
Standards/regulations | EN 61000-4-5 |
Input | ± 2 kV |
Signal | ± 1 kV |
Comments | Criterion B |
Conducted interference
Standards/regulations | EN 61000-4-6 |
Comments | Criterion A |
Voltage | 10 V |
Emitted interference
Standards/regulations | EN 55032 |
Comments | Class A, industrial applications |
Criteria
Criterion A | Normal operating behavior within the specified limits. |
Criterion B | Temporary impairment to operational behavior that is corrected by the device itself. |
Mounting
Mounting Type | DIN rail mounting |
Accessories
- 2707437 - DIN rail connector, color: green, nominal current: 8 A (parallel contacts), rated voltage (III/2): 125 V, number of positions: 5, product range: TBUS5-22,5.., pitch: 3.81 mm, mounting: DIN rail mounting, locking: without, mounting: without, type of packaging: packed in cardboard, Item with gold-plated contacts, bus connectors for connecting with electronics housings, 5 parallel contacts
Why Proax for Phoenix Contact 2313106?
Proax is an authorized distributor of Phoenix Contact 2313106 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size | 1 |
Recommended