Series FLK
FLK 50-4X14/EZ-DR/200KONFEK/S - Cable
Assembled shielded round cable; connection 1: IDC/FLK socket strip (1x 50-position); connection 2: IDC/FLK socket strip (4x 14-position) (The braided shield is routed to four separate cable ends.); cable length: 2 m
Technical Specifications
Insulation characteristics
Insulation | Functional insulation |
Insulation characteristics: Air clearances and creepage distances
Insulation | Functional insulation |
Overvoltage category | II |
Pollution degree | 2 |
Ambient conditions
Degree of Protection | IP00 |
Degree of protection (Installation location) | ≥ IP54 (Installation location) |
Ambient Temperature (Operation) | -40 °C ... 70 °C (fixed installation) |
Ambient Temperature (Operation) | -10 °C ... 70 °C (flexible installation) |
Ambient temperature (storage/transport) | -40 °C ... 80 °C |
Altitude | ≤ 2000 m |
Electrical properties
Operating Voltage | ≤ 25 V AC |
Operating voltage (DC) | ≤ 60 V DC |
Nominal operating mode | 100% operating factor |
Current (Per path, 50°C) | ≤ 1 A |
Current (Per path, 70°C) | ≤ 0.6 A |
Air clearances and creepage distances
Rated Insulation Voltage | 63 V |
Rated surge voltage | 0.6 kV |
Supported controller SIEMENS S7-400
Suitable I/O card | 6ES7421-1BL01-0AA0 |
Suitable I/O card | 6ES7422-1BL00-0AA0 |
Suitable I/O card | 6ES7422-7BL00-0AB0 |
Supported controller ALLEN-BRADLEY ControlLogix
Suitable I/O card | 1756-IB32 |
Suitable I/O card | 1756-OB32 |
Supported controller ALLEN-BRADLEY PLC 5
Suitable I/O card | 1771 IBN |
Suitable I/O card | 1771 OBN |
Supported controller HONEYWELL Experion PKS C200
Suitable I/O card | TC-IDD 321 |
Suitable I/O card | TC-ODD 321 |
Supported controller SCHNEIDER ELECTRIC Modicon TSX QUANTUM
Suitable I/O card | DDI 353 |
Suitable I/O card | DDI 853 |
Suitable I/O card | DAI 353 |
Suitable I/O card | DAI 453 |
Suitable I/O card | DDO 353 |
Supported controller SIEMENS S7-300 / ET 200 M
Suitable I/O card | CPU 313C-2DP |
Suitable I/O card | CPU 314C-2PtP |
Suitable I/O card | 6ES7321-1BL00-0AA0 |
Suitable I/O card | 6ES7322-1BL00-0AA0 |
Suitable I/O card | 6ES7323-1BL00-0AA0 |
Suitable I/O card | 6ES7331-7NF00-0AB0 |
Suitable I/O card | 6ES7331-7PF01-0AB0 |
Suitable I/O card | 6ES7331-7PF11-0AB0 |
Suitable I/O card | 6ES7350-2AH01-0AE0 |
Suitable I/O card | 6ES7357-4AH01-0AE0 |
Suitable I/O card | CPU 314C-2DP |
Suitable I/O card | CPU 313C |
Suitable I/O card | CPU 313C-2PtP |
Cable/line
Cable Length | 2 m |
14X0.14 [PVC]
Number of Positions | 14 |
Shielded | yes |
Cable Type | 14X0.14 [PVC] |
Conductor type | Assembled shielded round cable |
Conductor structure signal line | 7x 0.16 mm |
AWG Signal Line | 26 |
Conductor Cross Section | 14x 0.14 mm² |
Wire diameter incl. insulation | 1 mm ±0.03 mm |
External Cable Diameter | 6.70 mm ±0.4 mm |
Outer sheath, material | Semi-rigid PVC |
External sheath, color | gray |
Conductor material | Tin-plated Cu litz wires |
Cable resistance | ≤ 145 Ω/km (20 °C) |
Insulation resistance | ≥ 20 MΩ*km (20 °C) |
Smallest bending radius, fixed installation | 71 mm |
Smallest bending radius, movable installation | 128 mm |
Max. bending cycles | 5000 (at a radius of ≥ 15x outside diameter) |
Halogen-free | no |
Flame resistance | IEC 60332-1-2 (raw cable) |
Flame resistance | VDE 0842, Part 332-1-2 (raw cable) |
Flame resistance | IEC 60332-3-22 (raw cable) |
Flame resistance | UL VW-1 |
Flame resistance | CSA FT-1 |
Resistance to Oil | can withstand occasional splashes (raw cable) |
IDC/FLK50 (1) | IDC/FLK14-1 (9) = gray |
IDC/FLK50 (2) | IDC/FLK14-1 (11) = white-black |
IDC/FLK50 (3) | IDC/FLK14-1 (1) = black |
IDC/FLK50 (4) | IDC/FLK14-1 (2) = brown |
IDC/FLK50 (5) | IDC/FLK14-1 (3) = red |
IDC/FLK50 (6) | IDC/FLK14-1 (4) = orange |
IDC/FLK50 (7) | IDC/FLK14-1 (5) = yellow |
IDC/FLK50 (8) | IDC/FLK14-1 (6) = green |
IDC/FLK50 (9) | IDC/FLK14-1 (7) = blue |
IDC/FLK50 (10) | IDC/FLK14-1 (8) = violet |
IDC/FLK50 (11) | IDC/FLK14-1 (10) = white |
IDC/FLK50 (12) | IDC/FLK14-1 (12) = white-brown |
IDC/FLK50 (13) | IDC/FLK14-2 (9) = gray |
IDC/FLK50 (14) | IDC/FLK14-2 (11) = white-black |
IDC/FLK50 (15) | IDC/FLK14-2 (1) = black |
IDC/FLK50 (16) | IDC/FLK14-2 (2) = brown |
IDC/FLK50 (17) | IDC/FLK14-2 (3) = red |
IDC/FLK50 (18) | IDC/FLK14-2 (4) = orange |
IDC/FLK50 (19) | IDC/FLK14-2 (5) = yellow |
IDC/FLK50 (20) | IDC/FLK14-2 (6) = green |
IDC/FLK50 (21) | IDC/FLK14-2 (7) = blue |
IDC/FLK50 (22) | IDC/FLK14-2 (8) = violet |
IDC/FLK50 (23) | IDC/FLK14-2 (10) = white |
IDC/FLK50 (24) | IDC/FLK14-2 (12) = white-brown |
IDC/FLK50 (25) | IDC/FLK14-3 (9) = gray |
IDC/FLK50 (26) | IDC/FLK14-3 (11) = white-black |
IDC/FLK50 (27) | IDC/FLK14-3 (1) = black |
IDC/FLK50 (28) | IDC/FLK14-3 (2) = brown |
IDC/FLK50 (29) | IDC/FLK14-3 (3) = red |
IDC/FLK50 (30) | IDC/FLK14-3 (4) = orange |
IDC/FLK50 (31) | IDC/FLK14-3 (5) = yellow |
IDC/FLK50 (32) | IDC/FLK14-3 (6) = green |
IDC/FLK50 (33) | IDC/FLK14-3 (7) = blue |
IDC/FLK50 (34) | IDC/FLK14-3 (8) = violet |
IDC/FLK50 (35) | IDC/FLK14-3 (10) = white |
IDC/FLK50 (36) | IDC/FLK14-3 (12) = white-brown |
IDC/FLK50 (37) | IDC/FLK14-4 (9) = gray |
IDC/FLK50 (38) | IDC/FLK14-4 (11) = white-black |
IDC/FLK50 (39) | IDC/FLK14-4 (1) = black |
IDC/FLK50 (40) | IDC/FLK14-4 (2) = brown |
IDC/FLK50 (41) | IDC/FLK14-4 (3) = red |
IDC/FLK50 (42) | IDC/FLK14-4 (4) = orange |
IDC/FLK50 (43) | IDC/FLK14-4 (5) = yellow |
IDC/FLK50 (44) | IDC/FLK14-4 (6) = green |
IDC/FLK50 (45) | IDC/FLK14-4 (7) = blue |
IDC/FLK50 (46) | IDC/FLK14-4 (8) = violet |
IDC/FLK50 (47) | IDC/FLK14-4 (10) = white |
IDC/FLK50 (48) | IDC/FLK14-4 (12) = white-brown |
Cable Type | Splitting cable for four modules |
Field level
Connection in acc. with standard | IEC 60603-13 |
Connection Method | IDC/FLK socket strip |
Number of Connections | 4 |
Number of Positions | 14 |
Note | The braided shield is routed to four separate cable ends. |
Note | The separate cable end is approximately 0.5 m long (H05V-K 1 mm², black) |
Insertion/withdrawal cycles | > 50 |
Pitch | 2.54 mm |
Controller level
Connection in acc. with standard | IEC 60603-13 |
Connection Method | IDC/FLK socket strip |
Number of Connections | 1 |
Number of Positions | 50 |
Insertion/withdrawal cycles | > 50 |
Pitch | 2.54 mm |
Air clearances and creepage distances
Standards/regulations | DIN EN 50178 |
Notes
Notes on operation | For proper use, the specifications of the installation directive (see Downloads) must be observed. For applications or use with third-party products, the specifications, and the safety and warning instructions of the respective third-party manufacturer must also be met. |
Why Proax for Phoenix Contact 2302418?
Proax is an authorized distributor of Phoenix Contact 2302418 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size | 1 |
Recommended