Official Distributor
SKU
MPN
FLK 40/EZ-DR/ 300/SLC
Weight
0.431 kg
This product is Not Cancellable/Not Returnable
Series FLK
FLK 40/EZ-DR/ 300/SLC - Cable
Round cable set; controller: Allen-Bradley SLC 500 (OB 32, IB 32); connection 1: IDC/FLK socket strip (1x 40-position); connection 2: IDC/FLK socket strip (1x 40-position); cable length: 3 m
- Passive interface modules (VIP-3/SC/FLK40, etc.) are connected to the I/O cards using the system cable
Technical Specifications
Ambient conditions
Degree of Protection | IP00 |
Degree of protection (Installation location) | ≥ IP54 (Installation location) |
Ambient Temperature (Operation) | -40 °C ... 70 °C (fixed installation) |
Ambient Temperature (Operation) | -10 °C ... 70 °C (flexible installation) |
Ambient temperature (storage/transport) | -40 °C ... 80 °C |
Altitude | ≤ 2000 m |
Electrical properties
Operating voltage (AC) | ≤ 30 V AC |
Operating voltage (DC) | ≤ 60 V DC |
Nominal operating mode | 100% operating factor |
Current (Per path, 50°C) | ≤ 1 A (Uncoiled, see derating) |
Current (Per path, 70°C) | ≤ 0.6 A (Uncoiled, see derating) |
Supported controller ALLEN-BRADLEY SLC 500
Suitable I/O card | 1746 OB 32 |
Suitable I/O card | 1746 OV 32 |
Suitable I/O card | 1746 IB 32 |
Suitable I/O card | 1746 IV 32 |
Cable/line
Cable Length | 3 m |
40X0.14 [PVC]
UL AWM style | 2464/1061 |
Number of Positions | 40 |
Shielded | no |
Cable Type | 40X0.14 [PVC] |
Conductor type | Round cable set |
Conductor structure signal line | 7x 0.16 mm |
AWG Signal Line | 26 |
Conductor Cross Section | 40x 0.14 mm² |
Wire diameter incl. insulation | 1 mm ±0.03 mm |
External Cable Diameter | 9.90 mm ±0.4 mm |
Outer sheath, material | Semi-rigid PVC |
External sheath, color | gray |
Conductor material | Tin-plated Cu litz wires |
Cable resistance | ≤ 145 Ω/km (20 °C) |
Insulation resistance | ≥ 20 MΩ*km (20 °C) |
Smallest bending radius, fixed installation | 82 mm |
Smallest bending radius, movable installation | 155 mm |
Max. bending cycles | 5000 (at a radius of ≥ 15x outside diameter) |
Halogen-free | no |
Flame resistance | IEC 60332-1-2 (raw cable) |
Flame resistance | VDE 0842, Part 332-1-2 (raw cable) |
Flame resistance | IEC 60332-3-22 (raw cable) |
Flame resistance | UL VW-1 |
Flame resistance | CSA FT-1 |
Resistance to Oil | can withstand occasional splashes (raw cable) |
IDC/FLK40 (1) | IDC/FLK40 (1) = black |
IDC/FLK40 (2) | IDC/FLK40 (2) = brown |
IDC/FLK40 (3) | IDC/FLK40 (3) = red |
IDC/FLK40 (4) | IDC/FLK40 (4) = orange |
IDC/FLK40 (5) | IDC/FLK40 (5) = yellow |
IDC/FLK40 (6) | IDC/FLK40 (6) = green |
IDC/FLK40 (7) | IDC/FLK40 (7) = blue |
IDC/FLK40 (8) | IDC/FLK40 (8) = violet |
IDC/FLK40 (9) | IDC/FLK40 (9) = gray |
IDC/FLK40 (10) | IDC/FLK40 (10) = white |
IDC/FLK40 (11) | IDC/FLK40 (11) = white-black |
IDC/FLK40 (12) | IDC/FLK40 (12) = white-brown |
IDC/FLK40 (13) | IDC/FLK40 (13) = white-red |
IDC/FLK40 (14) | IDC/FLK40 (14) = white-orange |
IDC/FLK40 (15) | IDC/FLK40 (15) = white-yellow |
IDC/FLK40 (16) | IDC/FLK40 (16) = white-green |
IDC/FLK40 (17) | IDC/FLK40 (17) = white-blue |
IDC/FLK40 (18) | IDC/FLK40 (18) = white-violet |
IDC/FLK40 (19) | IDC/FLK40 (19) = white-gray |
IDC/FLK40 (20) | IDC/FLK40 (20) = brown-black |
IDC/FLK40 (21) | IDC/FLK40 (21) = brown-red |
IDC/FLK40 (22) | IDC/FLK40 (22) = brown-orange |
IDC/FLK40 (23) | IDC/FLK40 (23) = brown-yellow |
IDC/FLK40 (24) | IDC/FLK40 (24) = brown-green |
IDC/FLK40 (25) | IDC/FLK40 (25) = brown-blue |
IDC/FLK40 (26) | IDC/FLK40 (26) = brown-violet |
IDC/FLK40 (27) | IDC/FLK40 (27) = brown-gray |
IDC/FLK40 (28) | IDC/FLK40 (28) = brown-white |
IDC/FLK40 (29) | IDC/FLK40 (29) = green-black |
IDC/FLK40 (30) | IDC/FLK40 (30) = green-brown |
IDC/FLK40 (31) | IDC/FLK40 (31) = green-red |
IDC/FLK40 (32) | IDC/FLK40 (32) = green-orange |
IDC/FLK40 (33) | IDC/FLK40 (33) = green-blue |
IDC/FLK40 (34) | IDC/FLK40 (34) = green-violet |
IDC/FLK40 (35) | IDC/FLK40 (35) = green-gray |
IDC/FLK40 (36) | IDC/FLK40 (36) = green-white |
IDC/FLK40 (37) | IDC/FLK40 (37) = yellow-black |
IDC/FLK40 (38) | IDC/FLK40 (38) = yellow-brown |
IDC/FLK40 (39) | IDC/FLK40 (39) = yellow-red |
IDC/FLK40 (40) | IDC/FLK40 (40) = yellow-orange |
Cable Type | Cable for one module |
Connection 1
Connection in acc. with standard | based on IEC 60603-13 |
Connection Method | IDC/FLK socket strip |
Number of Connections | 1 |
Number of Positions | 40 |
Insertion/withdrawal cycles | > 50 |
Pitch | 2.54 mm |
Connection 2
Connection in acc. with standard | based on IEC 60603-13 |
Connection Method | IDC/FLK socket strip |
Number of Connections | 1 |
Number of Positions | 40 |
Insertion/withdrawal cycles | > 50 |
Pitch | 2.54 mm |
Notes
Notes on operation | For proper use, the specifications of the installation directive (see Downloads) must be observed. For applications or use with third-party products, the specifications, and the safety and warning instructions of the respective third-party manufacturer must also be met. |
Accessories
Why Proax for Phoenix Contact 2294652?
Proax is an authorized distributor of Phoenix Contact 2294652 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size | 1 |
Recommended