Proax

Currency
0 Items
proax logo
Cart
Phoenix ContactOfficial Distributor

By Phoenix Contact

SKU
MPN
FLK 40/EZ-DR/ 200/SLC
Weight
0.296 kg
This product is Not Cancellable/Not Returnable
Series FLK

FLK 40/EZ-DR/ 200/SLC - Cable

Round cable set; controller: Allen-Bradley SLC 500 (OB 32, IB 32); connection 1: IDC/FLK socket strip (1x 40-position); connection 2: IDC/FLK socket strip (1x 40-position); cable length: 2 m

  • Passive interface modules (VIP-3/SC/FLK40, etc.) are connected to the I/O cards using the system cable
Technical Specifications

Ambient conditions

Degree of ProtectionIP00
Degree of protection (Installation location)≥ IP54 (Installation location)
Ambient Temperature (Operation)-40 °C ... 70 °C (fixed installation)
Ambient Temperature (Operation)-10 °C ... 70 °C (flexible installation)
Ambient temperature (storage/transport)-40 °C ... 80 °C
Altitude≤ 2000 m

Electrical properties

Operating voltage (AC)≤ 30 V AC
Operating voltage (DC)≤ 60 V DC
Nominal operating mode100% operating factor
Current (Per path, 50°C)≤ 1 A (Uncoiled, see derating)
Current (Per path, 70°C)≤ 0.6 A (Uncoiled, see derating)

Supported controller ALLEN-BRADLEY SLC 500

Suitable I/O card1746 OB 32
Suitable I/O card1746 OV 32
Suitable I/O card1746 IB 32
Suitable I/O card1746 IV 32

Cable/line

Cable Length2 m

40X0.14 [PVC]

UL AWM style2464/1061
Number of Positions40
Shieldedno
Cable Type40X0.14 [PVC]
Conductor typeRound cable set
Conductor structure signal line7x 0.16 mm
AWG Signal Line26
Conductor Cross Section40x 0.14 mm²
Wire diameter incl. insulation1 mm ±0.03 mm
External Cable Diameter9.90 mm ±0.4 mm
Outer sheath, materialSemi-rigid PVC
External sheath, colorgray
Conductor materialTin-plated Cu litz wires
Cable resistance≤ 145 Ω/km (20 °C)
Insulation resistance≥ 20 MΩ*km (20 °C)
Smallest bending radius, fixed installation82 mm
Smallest bending radius, movable installation155 mm
Max. bending cycles5000 (at a radius of ≥ 15x outside diameter)
Halogen-freeno
Flame resistanceIEC 60332-1-2 (raw cable)
Flame resistanceVDE 0842, Part 332-1-2 (raw cable)
Flame resistanceIEC 60332-3-22 (raw cable)
Flame resistanceUL VW-1
Flame resistanceCSA FT-1
Resistance to Oilcan withstand occasional splashes (raw cable)
IDC/FLK40 (1)IDC/FLK40 (1) = black
IDC/FLK40 (2)IDC/FLK40 (2) = brown
IDC/FLK40 (3)IDC/FLK40 (3) = red
IDC/FLK40 (4)IDC/FLK40 (4) = orange
IDC/FLK40 (5)IDC/FLK40 (5) = yellow
IDC/FLK40 (6)IDC/FLK40 (6) = green
IDC/FLK40 (7)IDC/FLK40 (7) = blue
IDC/FLK40 (8)IDC/FLK40 (8) = violet
IDC/FLK40 (9)IDC/FLK40 (9) = gray
IDC/FLK40 (10)IDC/FLK40 (10) = white
IDC/FLK40 (11)IDC/FLK40 (11) = white-black
IDC/FLK40 (12)IDC/FLK40 (12) = white-brown
IDC/FLK40 (13)IDC/FLK40 (13) = white-red
IDC/FLK40 (14)IDC/FLK40 (14) = white-orange
IDC/FLK40 (15)IDC/FLK40 (15) = white-yellow
IDC/FLK40 (16)IDC/FLK40 (16) = white-green
IDC/FLK40 (17)IDC/FLK40 (17) = white-blue
IDC/FLK40 (18)IDC/FLK40 (18) = white-violet
IDC/FLK40 (19)IDC/FLK40 (19) = white-gray
IDC/FLK40 (20)IDC/FLK40 (20) = brown-black
IDC/FLK40 (21)IDC/FLK40 (21) = brown-red
IDC/FLK40 (22)IDC/FLK40 (22) = brown-orange
IDC/FLK40 (23)IDC/FLK40 (23) = brown-yellow
IDC/FLK40 (24)IDC/FLK40 (24) = brown-green
IDC/FLK40 (25)IDC/FLK40 (25) = brown-blue
IDC/FLK40 (26)IDC/FLK40 (26) = brown-violet
IDC/FLK40 (27)IDC/FLK40 (27) = brown-gray
IDC/FLK40 (28)IDC/FLK40 (28) = brown-white
IDC/FLK40 (29)IDC/FLK40 (29) = green-black
IDC/FLK40 (30)IDC/FLK40 (30) = green-brown
IDC/FLK40 (31)IDC/FLK40 (31) = green-red
IDC/FLK40 (32)IDC/FLK40 (32) = green-orange
IDC/FLK40 (33)IDC/FLK40 (33) = green-blue
IDC/FLK40 (34)IDC/FLK40 (34) = green-violet
IDC/FLK40 (35)IDC/FLK40 (35) = green-gray
IDC/FLK40 (36)IDC/FLK40 (36) = green-white
IDC/FLK40 (37)IDC/FLK40 (37) = yellow-black
IDC/FLK40 (38)IDC/FLK40 (38) = yellow-brown
IDC/FLK40 (39)IDC/FLK40 (39) = yellow-red
IDC/FLK40 (40)IDC/FLK40 (40) = yellow-orange
Cable TypeCable for one module

Connection 1

Connection in acc. with standardbased on IEC 60603-13
Connection MethodIDC/FLK socket strip
Number of Connections1
Number of Positions40
Insertion/withdrawal cycles> 50
Pitch2.54 mm

Connection 2

Connection in acc. with standardbased on IEC 60603-13
Connection MethodIDC/FLK socket strip
Number of Connections1
Number of Positions40
Insertion/withdrawal cycles> 50
Pitch2.54 mm

Notes

Notes on operationFor proper use, the specifications of the installation directive (see Downloads) must be observed. For applications or use with third-party products, the specifications, and the safety and warning instructions of the respective third-party manufacturer must also be met.
Accessories

Why Proax for Phoenix Contact 2294649?

Proax is an authorized distributor of Phoenix Contact 2294649 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Pack Size1
Recommended

Available for order

Phoenix Contact Availability