Proax

Currency
0 Items
proax logo
Cart
ABBOfficial Distributor

By ABB

SKU
MPN
1SBH137001R1140
Weight
0.281 kg
NF contactor relays are used for switching auxiliary and control circuits. NF contactor relays include an electronic coil interface accepting a wide control voltage Uc min. ... Uc max. Only four coils cover control voltages between 24...500 V 50/60 Hz or 20...500 V DC. NF contactor relays can manage large control voltage variations. One coil can be used for different control voltages used worldwide without any coil change. NF contactor relays have built-in surge protection and do not require additional surge suppressors. - Poles: 4-pole contactor relays - Control Circuit: AC or DC operated - Accessories: a wide range of Accessories is available. Note: NF..E-11 not suitable for a direct control by PLC-output. NF..E-11 type available in some countries: please consult your ABB representative.
Technical Specifications

Dimensions

Product Net Width45 mm
Product Net Depth / Length77 mm
Product Net Height86 mm
Product Net Weight0.27 kg

Technical

Number of Auxiliary Contacts NO4
Number of Auxiliary Contacts NC0
StandardsIEC/EN 60947-1, IEC/EN 60947-5-1, UL 508, CSA C22.2 No. 14-13
Rated Operational VoltageAuxiliary Circuit 690 V
Rated Frequency (f)Auxiliary Circuit 50 / 60 Hz
Rated Frequency (f)Control Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)acc. to IEC 60947-5-1, Θ = 40 °C 16 A
Rated Operational Current AC-15 (Ie)(500 V) 2 A
Rated Operational Current AC-15 (Ie)(690 V) 2 A
Rated Operational Current AC-15 (Ie)(24 / 127 V) 6 A
Rated Operational Current AC-15 (Ie)(220 / 240 V) 4 A
Rated Operational Current AC-15 (Ie)(400 / 440 V) 3 A
Rated Short-time Withstand Current Low Voltage (Icw)for 0.1 s 140 A
Rated Short-time Withstand Current Low Voltage (Icw)for 1 s 100 A
Maximum Electrical Switching Frequency(AC-15) 1200 cycles per hour
Maximum Electrical Switching Frequency(DC-13) 900 cycles per hour
Rated Operational Current DC-13 (Ie)(24 V) 6 A / 144 W
Rated Operational Current DC-13 (Ie)(48 V) 2.8 A / 134 W
Rated Operational Current DC-13 (Ie)(72 V) 1 A / 72 W
Rated Operational Current DC-13 (Ie)(110 V) 0.55 A / 60 W
Rated Operational Current DC-13 (Ie)(125 V) 0.55 A / 69 W
Rated Operational Current DC-13 (Ie)(220 V) 0.27 A / 60 W
Rated Operational Current DC-13 (Ie)(250 V) 0.27 A / 68 W
Rated Operational Current DC-13 (Ie)(400 V) 0.15 A / 60 W
Rated Operational Current DC-13 (Ie)(500 V) 0.13 A / 65 W
Rated Operational Current DC-13 (Ie)(600 V) 0.1 A / 60 W
Rated Insulation Voltage (Ui)acc. to IEC 60947-5-1 690 V
Rated Insulation Voltage (Ui)acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)6 kV
Maximum Mechanical Switching Frequency6000 cycles per hour
Rated Control Circuit Voltage (Uc)50 Hz 24 ... 60 V
Rated Control Circuit Voltage (Uc)60 Hz 24 ... 60 V
Rated Control Circuit Voltage (Uc)DC Operation 20 ... 60 V
Operate TimeBetween Coil De-energization and NC Contact Closing 13 ... 98 ms
Operate TimeBetween Coil De-energization and NO Contact Opening 11 ... 95 ms
Operate TimeBetween Coil Energization and NC Contact Opening 38 ... 90 ms
Operate TimeBetween Coil Energization and NO Contact Closing 40 ... 95 ms
Mounting on DIN RailTH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
Mounting on DIN RailTH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied)2 x M4 screws placed diagonally
Connecting Capacity Auxiliary CircuitFlexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Connecting Capacity Auxiliary CircuitFlexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Connecting Capacity Auxiliary CircuitFlexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Connecting Capacity Auxiliary CircuitRigid Solid 1/2x 1 ... 2.5 mm²
Connecting Capacity Auxiliary CircuitRigid Stranded 1/2x 1 ... 2.5 mm²
Connecting Capacity Control CircuitFlexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Connecting Capacity Control CircuitFlexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Connecting Capacity Control CircuitFlexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Connecting Capacity Control CircuitRigid Solid 1/2x 1 ... 2.5 mm²
Connecting Capacity Control CircuitRigid Stranded 1/2x 1 ... 2.5 mm²
Wire Stripping LengthAuxiliary Circuit 10 mm
Wire Stripping LengthControl Circuit 10 mm
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
Terminal TypeScrew Terminals

Technical UL/CSA

Connecting Capacity Auxiliary Circuit UL/CSARigid Solid 1/2x 18-14 AWG
Connecting Capacity Auxiliary Circuit UL/CSARigid Stranded 1/2x 18-14 AWG
Tightening Torque UL/CSAAuxiliary Circuit 11 in·lb
Tightening Torque UL/CSAControl Circuit 11 in·lb

Why Proax for ABB NF40E-11?

Proax is an authorized distributor of ABB NF40E-11 and one of ABB's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Alternate NamesNF40E11
Pack Size1
Recommended

Not in stock

Request lead time or order—we'll ensure quick delivery

ABB Availability