MS132-2.5

By ABB

ABBMS1322:5
ABBOfficial Distributor
The MS132-2.5 manual motor starter (also known as motor protection circuit breaker or manual motor protector) is a compact 45 mm width device with a rated operational current of Ie = 2.50 A. This device is used to manually switch on and off motors and to protect them reliably and without the need for a fuse from short-circuits, overload and phase failures. The manual motor starter offers a rated service short-circuit breaking capacity Ics = 100 kA at 400 VAC and trip class 10. Further features are the build-in disconnect function, temperature compensation, trip-free mechanism and a rotary handle with a clear switch position indication. The manual motor starter is suitable for three- and single-phase applications. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signaling contacts, undervoltage releases, shunt trips, 3-phase bus bars, power in-feed blocks and terminal spacers are available as accessory.
Technical Specifications

Dimensions

Product Net Width45 mm
Product Net Height90 mm
Product Net Depth / Length86.75 mm
Product Net Weight0.265 kg

Technical

Rated Service Short-Circuit Breaking Capacity (Ics)(230 V AC) 100 kA, (250 V DC) 3 Poles in Series 10 kA, (400 V AC) 100 kA, (440 V AC) 100 kA, (500 V AC) 100 kA, (690 V AC) 100 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)(230 V AC) 100 kA, (400 V AC) 100 kA, (440 V AC) 100 kA, (500 V AC) 100 kA, (690 V AC) 100 kA
Rated Instantaneous Short-Circuit Current Setting (Ii)31.3 A
Setting range1.6 ... 2.5 A
Rated Operational Power AC-3 (Pe)(400 V) Three Phase 0.75 kW
Rated Operational Power AC-3e (Pe)(400 V) Three Phase 0.75 kW
Rated Operational VoltageMain Circuit 690 V AC, Main Circuit 250 V DC
Rated Operational Current (Ie)2.5 A
Rated Operational Current AC-3 (Ie)2.5 A
Rated Operational Current AC-3e (Ie)2.5 A
Rated Operational Current DC-5 (Ie)2.5 A
Rated Frequency (f)Main Circuit 50 Hz, Main Circuit 60 Hz
Rated Impulse Withstand Voltage (Uimp)Main Circuit 6 kV
Rated Insulation Voltage (Ui)690 V
Power Lossat Rated Operating Conditions per Pole 0.7 ... 1.8 W
Number of Poles3
Conventional Free-air Thermal Current (Ith)Main Circuit 2.5 A
Degree of ProtectionHousing IP20, Main Circuit Terminals IP10
Pollution degree3
Electrical Durability50000 cycle
Mechanical Durability100000 cycle
Terminal TypeScrew Terminals
Connecting Capacity Main CircuitFlexible with Ferrule 1/2x 0.75 ... 2.5 mm², Flexible with Insulated Ferrule 1/2x 0.75 ... 2.5 mm², Flexible 1/2x 0.75 ... 2.5 mm², Rigid 1/2x 1 ... 4 mm²
Tightening torqueMain Circuit 0.8 ... 1.2 N·m
Wire Stripping LengthMain Circuit 9 mm
Recommended Screw DriverPozidriv 2
Mounting Position1 ... 6
Mounting on DIN RailTH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715, TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Minimum Mounting DistanceElectrical Conductive Board, Horizontal - Up to 400 V 0 mm, Electrical Conductive Board, Horizontal - Up to 690 V 1.5 mm, Electrical Conductive Board, Vertical 75 mm, Other Device Same Type, Horizontal 0 mm, Other Device Same Type, Vertical 150 mm
Actuator TypeRotary Handle
Contact Position IndicationON / OFF / TRIP
StandardsIEC/EN 60947-1, IEC/EN 60947-2, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1
RemarksUL508 Self-Protected Combination Motor Controller (Type E) in combination with feeder block S1-M3-xx

Technical UL/CSA

Short-circuit current rating (SCCR)Manual Self-Protected Combination Controllers (Type E), (480Y / 277 V AC) 65 kA, Manual Self-Protected Combination Controllers (Type E), (600Y / 347 V AC) 47 kA, Any UL Listed Fuses or Circuit-Breakers, Group Installations (480 V AC) 65 kA, Any UL Listed Fuses or Circuit-Breakers, Group Installations (600 V AC) 47 kA, Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (480 V AC) 65 kA, Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (600 V AC) 47 kA, Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (480Y / 277 V AC) 65 kA, Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (600Y / 347 V AC) 47 kA
Maximum Operating Voltage UL/CSAMain Circuit 600 V AC
Horsepower Rating UL/CSA(200 V AC) Three Phase 0.5 Hp, (208 V AC) Three Phase 0.5 Hp, (220 ... 240 V AC) Three Phase 0.5 Hp, (440 ... 480 V AC) Three Phase 1 Hp, (550 ... 600 V AC) Three Phase 1.5 Hp
Full Load Amps Motor Use(200 V AC) Three Phase 2.5 A, (208 V AC) Three Phase 2.5 A, (220 ... 240 V AC) Three Phase 2.5 A, (440 ... 480 V AC) Three Phase 2.5 A, (550 ... 600 V AC) Three Phase 2.5 A
Locked Rotor Amps(200 V AC) Three Phase 15 A, (208 V AC) Three Phase 15 A, (220 ... 240 V AC) Three Phase 15 A, (440 ... 480 V AC) Three Phase 15 A, (550 ... 600 V AC) Three Phase 15 A
General Use Rating UL/CSA(600 V AC) 2.5 A
Connecting Capacity Main Circuit UL/CSAFlexible 1/2x 16-12 AWG, Stranded 1/2x 16-12 AWG
Tightening Torque UL/CSAMain Circuit 10 ... 12 in·lb

Environmental

Ambient Air TemperatureAround the Enclosure 0 ... +40 °C, Operation -25 ... +70 °C, Operation Compensated -25 ... +60 °C, Storage -50 ... +80 °C
Ambient Air Temperature CompensationYes
Maximum Operating Altitude Permissible2000 m
Resistance to Shock acc. to IEC 60068-2-2711 ms Pulse 25g
Resistance to Vibrations acc. to IEC 60068-2-65g / 3 ... 150 Hz
RoHS StatusFollowing EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019

Why Proax for ABB MS132-2.5?

Proax is an authorized distributor of ABB MS132-2.5 and one of ABB's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Recommended

Available for order