CADEN
Cart

NF71EK-14

Official Distributor

By ABB

SKU
ABBNF71EK14
MPN
1SBH137005R1471
Weight
0.37 kg
The NF71EK-14 is a 690 V IEC or 600 UL 8-pole contactor relay with Push-in Spring terminals, used for switching auxiliary and control circuits. Only one push is all you need for extremely fast wiring: faster than ever installation, easier than ever wiring, reliable as ever connections. Thanks to the AF technology, the contactor relay has a wide control voltage range (250-500 V 50/60 Hz and DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. NF contactor relays have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories. These contactor relays include mechanically-linked auxiliary contacts compliant with Annex L of IEC 60947-5-1 and are side-marked with the "Mechanically Linked" symbol.
Technical Specifications

Dimensions

Product Net Width45 mm
Product Net Depth / Length110.5 mm
Product Net Height92.3 mm
Product Net Weight0.37 kg

Technical

Number of Auxiliary Contacts NO7
Number of Auxiliary Contacts NC1
Number of Poles8P
StandardsIEC/EN 60947-1, IEC/EN 60947-5-1, UL 508, CSA C22.2 No. 14-13
Rated Operational VoltageAuxiliary Circuit 690 V
Rated Operational VoltageMain Circuit 690 V
Rated Frequency (f)Auxiliary Circuit 50 / 60 Hz
Rated Frequency (f)Control Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)acc. to IEC 60947-5-1, Θ = 40 °C 16 A
Rated Operational Current AC-15 (Ie)(500 V) 2 A
Rated Operational Current AC-15 (Ie)(690 V) 2 A
Rated Operational Current AC-15 (Ie)(24 / 127 V) 6 A
Rated Operational Current AC-15 (Ie)(220 / 240 V) 4 A
Rated Operational Current AC-15 (Ie)(400 / 440 V) 3 A
Rated Operational Current DC-13 (Ie)(24 V) 6 A / 144 W
Rated Operational Current DC-13 (Ie)(48 V) 2.8 A / 134 W
Rated Operational Current DC-13 (Ie)(72 V) 1 A / 72 W
Rated Operational Current DC-13 (Ie)(110 V) 0.55 A / 60 W
Rated Operational Current DC-13 (Ie)(125 V) 0.55 A / 69 W
Rated Operational Current DC-13 (Ie)(220 V) 0.27 A / 60 W
Rated Operational Current DC-13 (Ie)(250 V) 0.27 A / 68 W
Rated Operational Current DC-13 (Ie)(400 V) 0.15 A / 60 W
Rated Operational Current DC-13 (Ie)(500 V) 0.13 A / 65 W
Rated Operational Current DC-13 (Ie)(600 V) 0.1 A / 60 W
Rated Short-time Withstand Current Low Voltage (Icw)for 0.1 s 140 A
Rated Short-time Withstand Current Low Voltage (Icw)for 1 s 100 A
Rated Insulation Voltage (Ui)acc. to IEC 60947-5-1 690 V
Rated Insulation Voltage (Ui)acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)6 kV
Maximum Electrical Switching Frequency(AC-15) 1200 cycles per hour
Maximum Electrical Switching Frequency(DC-13) 900 cycles per hour
Maximum Mechanical Switching Frequency6000 cycles per hour
Rated Control Circuit Voltage (Uc)50 Hz 250 ... 500 V
Rated Control Circuit Voltage (Uc)60 Hz 250 ... 500 V
Rated Control Circuit Voltage (Uc)DC Operation 250 ... 500 V
Power Lossat 6 A per Pole 0.1 W
Operate TimeBetween Coil De-energization and NC Contact Closing 13 ... 98 ms
Operate TimeBetween Coil De-energization and NO Contact Opening 11 ... 95 ms
Operate TimeBetween Coil Energization and NC Contact Opening 38 ... 90 ms
Operate TimeBetween Coil Energization and NO Contact Closing 40 ... 95 ms
Mounting on DIN RailTH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
Mounting on DIN RailTH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied) 2 x M4 Screws Placed Diagonally
Connecting Capacity Auxiliary CircuitFlexible with Ferrule 1/2x 0.5 ... 2.5 mm²
Connecting Capacity Auxiliary CircuitFlexible with Insulated Ferrule 1/2x 0.5 ... 1.5 mm²
Connecting Capacity Auxiliary CircuitFlexible 1/2x 0.5 ... 2.5 mm²
Connecting Capacity Auxiliary CircuitRigid Solid 1/2x 1 ... 2.5 mm²
Connecting Capacity Control CircuitFlexible with Ferrule 1/2x 0.5 ... 2.5 mm²
Connecting Capacity Control CircuitFlexible with Insulated Ferrule 1/2x 0.5 ... 1.5 mm²
Connecting Capacity Control CircuitFlexible 1/2x 0.5 ... 2.5 mm²
Connecting Capacity Control CircuitRigid Solid 1/2x 1 ... 2.5 mm²
Wire Stripping LengthAuxiliary Circuit 10 mm
Wire Stripping LengthControl Circuit 10 mm
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
Terminal TypePush-in Spring Terminals
Product NameBlock Contactor Relay

Technical UL/CSA

Connecting Capacity Auxiliary Circuit UL/CSARigid Solid 1/2x 18-14 AWG
Connecting Capacity Control Circuit UL/CSARigid Solid 1/2x 18-14 AWG

ABB EcoSolutions

End Of Life Disassembling Instructions1SBC101080M6801
Environmental Product Declaration - EPD1SBD250584E3000
Sustainable Material Content in Packaging (wt. %)Recycled Cardboard - 86 %
Sustainable Material Content in Product (wt. %)Recycled Metal - 28 %

Why Proax for ABB NF71EK-14?

Proax is an authorized distributor of ABB NF71EK-14 and one of ABB's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Alternate NamesNF71EK14
Pack Size1
Recommended

CAD$139.39

Not in stock

Request lead time or order—we'll ensure quick delivery

ABB Availability