MS165 is a compact and powerful range for motor protection up to 45 kW (400 V) / 80 A in width of 55 mm. They offer a reliable protection for motors in the event of overload or phase failure. The devices have trip class 10.
This type has also a clear and reliable indication of fault in a separate window in the event of short-circuit tripping. Further features are the build-in disconnect function, temperature compensation, trip-free mechanism and a rotary handle with a clear switch position indication. The manual motor starter (also known as motor protection circuit breaker or manual motor protector) is suitable for three- and single phase applications. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signaling contacts, undervoltage releases, shunt trips, power in-feed blocks are available as accessory. These
are suitable throughout the MS116/MS132/MS165 range.
Technical Specifications
Dimensions
Product Net Width | 55 mm |
Product Net Height | 142.65 mm |
Product Net Depth / Length | 122 mm |
Product Net Weight | 1 kg |
Technical
Rated Service Short-Circuit Breaking Capacity (Ics) | (230 V AC) 30 kA |
Rated Service Short-Circuit Breaking Capacity (Ics) | (250 V DC) 3 Poles in Series 100 kA |
Rated Service Short-Circuit Breaking Capacity (Ics) | (400 V AC) 30 kA |
Rated Service Short-Circuit Breaking Capacity (Ics) | (440 V AC) 18 kA |
Rated Service Short-Circuit Breaking Capacity (Ics) | (500 V AC) 10 kA |
Rated Service Short-Circuit Breaking Capacity (Ics) | (690 V AC) 6 kA |
Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (230 V AC) 30 kA |
Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (250 V DC) 100 kA |
Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 30 kA |
Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (440 V AC) 18 kA |
Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (500 V AC) 10 kA |
Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (690 V AC) 8 kA |
Rated Instantaneous Short-Circuit Current Setting (Ii) | 1120 A |
Setting range | 70 ... 80 A |
Rated Operational Power AC-3 (Pe) | (400 V) Three Phase 45 kW |
Rated Operational Power AC-3e (Pe) | (400 V) Three Phase 45 kW |
Rated Operational Voltage | Main Circuit 690 V AC |
Rated Operational Voltage | Main Circuit 250 V DC |
Rated Operational Current (Ie) | 80 A |
Rated Operational Current AC-3 (Ie) | 80 A |
Rated Operational Current AC-3e (Ie) | 80 A |
Rated Operational Current DC-5 (Ie) | 80 A |
Rated Frequency (f) | Main Circuit 50 Hz |
Rated Frequency (f) | Main Circuit 60 Hz |
Operating Frequency (fsw) | 0 ... 415 Hz |
Rated Impulse Withstand Voltage (Uimp) | Main Circuit 8 kV |
Rated Insulation Voltage (Ui) | 1000 V |
Power Loss | at Rated Operating Conditions per Pole 6.27 ... 8.33 W |
Number of Poles | 3 |
Conventional Free-air Thermal Current (Ith) | Main Circuit 80 A |
Degree of Protection | Housing IP20 |
Degree of Protection | Main Circuit Terminals IP10 |
Pollution degree | 3 |
Electrical Durability | 20000 cycle |
Mechanical Durability | 50000 cycle |
Terminal Type | Screw Terminals |
Connecting Capacity Main Circuit | Flexible with Ferrule 1/2x 1 ... 35 mm² |
Connecting Capacity Main Circuit | Flexible with Insulated Ferrule 1/2x 1 ... 35 mm² |
Connecting Capacity Main Circuit | Flexible 1/2x 1 ... 35 mm² |
Connecting Capacity Main Circuit | Rigid 1/2x 1 ... 4 mm² |
Connecting Capacity Main Circuit | Solid 1/2x 1 ... 4 mm² |
Connecting Capacity Main Circuit | Stranded 1/2x 1 ... 50 mm² |
Tightening torque | Main Circuit 4 N·m |
Wire Stripping Length | Main Circuit 16 mm |
Recommended Screw Driver | Pozidriv 2 |
Mounting Position | 1 ... 6 |
Mounting on DIN Rail | TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 |
Mounting on DIN Rail | TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715 |
Minimum Mounting Distance | Electrical Conductive Board, Horizontal - Up to 1000 V 1.5 mm |
Minimum Mounting Distance | Electrical Conductive Board, Horizontal - Up to 400 V 0 mm |
Minimum Mounting Distance | Electrical Conductive Board, Horizontal - Up to 690 V 1.5 mm |
Minimum Mounting Distance | Electrical Conductive Board, Vertical 75 mm |
Minimum Mounting Distance | Other Device Same Type, Horizontal 0 mm |
Minimum Mounting Distance | Other Device Same Type, Vertical 150 mm |
Actuator Type | Rotary Handle |
Contact Position Indication | ON / OFF / TRIP |
Standards | CSA 22.2 No. 14 |
Standards | IEC/EN 60947-1 |
Standards | IEC/EN 60947-2 |
Standards | IEC/EN 60947-4-1 |
Standards | UL 60947-4-1 |
Technical UL/CSA
Short-circuit current rating (SCCR) | Manual Self-Protected Combination Controllers (Type E), (480Y / 277 V AC) 50 kA |
Short-circuit current rating (SCCR) | Any UL Listed Fuses or Circuit-Breakers, Group Installations (480 V AC) 50 kA |
Short-circuit current rating (SCCR) | Any UL Listed Fuses or Circuit-Breakers, Group Installations (600 V AC) 10 kA |
Short-circuit current rating (SCCR) | Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (480 V AC) 50 kA |
Short-circuit current rating (SCCR) | Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (600 V AC) 10 kA |
Short-circuit current rating (SCCR) | Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (480Y / 277 V AC) 50 kA |
Short-circuit current rating (SCCR) | Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (600Y / 347 V AC) 10 kA |
Maximum Operating Voltage UL/CSA | Main Circuit 600 V AC |
Horsepower Rating UL/CSA | (200 V AC) Three Phase 25 Hp |
Horsepower Rating UL/CSA | (208 V AC) Three Phase 25 Hp |
Horsepower Rating UL/CSA | (220 ... 240 V AC) Three Phase 30 Hp |
Horsepower Rating UL/CSA | (440 ... 480 V AC) Three Phase 60 Hp |
Horsepower Rating UL/CSA | (550 ... 600 V AC) Three Phase 75 Hp |
Full Load Amps Motor Use | (110 ... 120 V AC) Three Phase 56 A |
Full Load Amps Motor Use | (200 V AC) Three Phase 78.2 A |
Full Load Amps Motor Use | (208 V AC) Three Phase 74.8 A |
Full Load Amps Motor Use | (220 ... 240 V AC) Three Phase 80 A |
Full Load Amps Motor Use | (440 ... 480 V AC) Three Phase 77 A |
Full Load Amps Motor Use | (550 ... 600 V AC) Three Phase 77 A |
Locked Rotor Amps | (200 V AC) Three Phase 420 A |
Locked Rotor Amps | (208 V AC) Three Phase 404 A |
Locked Rotor Amps | (220 ... 240 V AC) Three Phase 435 A |
Locked Rotor Amps | (440 ... 480 V AC) Three Phase 435 A |
Locked Rotor Amps | (550 ... 600 V AC) Three Phase 434 A |
General Use Rating UL/CSA | (600 V AC) 80 A |
Connecting Capacity Main Circuit UL/CSA | Flexible 1/2x 16-0 AWG |
Connecting Capacity Main Circuit UL/CSA | Stranded 1/2x 16-0 AWG |
Tightening Torque UL/CSA | Main Circuit 35 in·lb |
Why Proax for ABB MS165-80?
Proax is an authorized distributor of ABB MS165-80 and one of ABB's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Alternate Names | MS16580 |
Pack Size | 1 |
Recommended