AF300B-30-11RT-69

Official Distributor

By ABB

SKU
ABBAF300B3011RT69
MPN
1SFL557062R6911
Weight
5.4 kg
A 3-phase Contactor suitable for Rail way applications application. Operated with a wide voltage control voltage range 48-130 V, AC/DC
Technical Specifications

Dimensions

Product Net Width140 mm
Product Net Depth / Length180.5 mm
Product Net Height227 mm
Product Net Weight5.4 kg
Dimension Diagram53540930-2

Technical

Number of Main Contacts NO3
Number of Main Contacts NC0
Number of Auxiliary Contacts NO1
Number of Auxiliary Contacts NC1
Number of Poles3P
StandardsIEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1, IEC 60077-1 (applicable parts), IEC 60077-2 (applicable parts), EN 50155 (applicable parts), TR CU 001/2011, IEC 61373, For compliance confirmation on applicable parts based on your application and combination, please consult your ABB sales representatives.
Rated Operational VoltageMain Circuit 690 V
Rated Frequency (f)Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 500 A
Rated Operational Current AC-1 (Ie)(690 V) 40 °C 500 A
Rated Operational Current AC-1 (Ie)(690 V) 55 °C 400 A
Rated Operational Current AC-1 (Ie)(690 V) 70 °C 325 A
Rated Operational Current AC-3 (Ie)(415 V) 55 °C 300 A
Rated Operational Current AC-3 (Ie)(440 V) 55 °C 280 A
Rated Operational Current AC-3 (Ie)(500 V) 55 °C 280 A
Rated Operational Current AC-3 (Ie)(690 V) 55 °C 280 A
Rated Operational Current AC-3 (Ie)(380 / 400 V) 55 °C 305 A
Rated Operational Current AC-3 (Ie)(220 / 230 / 240 V) 55 °C 305
Rated Operational Current DC-1 (Ie)(110 V) 2 Poles in Series, 40 °C 450 A
Rated Operational Current DC-1 (Ie)(220 V) 3 Poles in Series, 40 °C 450 A
Rated Operational Current DC-3 (Ie)(110 V) 2 Poles in Series, 40 °C 450 A
Rated Operational Current DC-3 (Ie)(220 V) 3 Poles in Series, 40 °C 450 A
Rated Operational Current DC-5 (Ie)(110 V) 2 Poles in Series, 40 °C 450 A
Rated Operational Current DC-5 (Ie)(220 V) 3 Poles in Series, 40 °C 450 A
Rated Operational Power AC-3 (Pe)(415 V) 160 kW
Rated Operational Power AC-3 (Pe)(440 V) 160 kW
Rated Operational Power AC-3 (Pe)(500 V) 200 kW
Rated Operational Power AC-3 (Pe)(690 V) 250 kW
Rated Operational Power AC-3 (Pe)(380 / 400 V) 160 kW
Rated Operational Power AC-3 (Pe)(220 / 230 / 240 V) 90 kW
Rated Breaking Capacity AC-38 x Ie AC-3
Rated Making Capacity AC-310 x Ie AC-3
Short-Circuit Protective DevicesgG Type Fuses 500 A
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 2400 A
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 500 A
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 1100 A
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 3500 A
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 1500 A
Maximum Breaking Capacitycos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 3000 A
Maximum Breaking Capacitycos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 2500 A
Rated Insulation Voltage (Ui)acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
Rated Insulation Voltage (Ui)acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)Main Circuit 8 kV
Maximum Electrical Switching Frequency(AC-1) 300 cycles per hour
Maximum Electrical Switching Frequency(AC-2 / AC-4) 150 cycles per hour
Maximum Electrical Switching Frequency(AC-3) 300 cycles per hour
Mechanical Durability5 million
Maximum Mechanical Switching Frequency300 cycles per hour
Coil Operating Limits(acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)
Rated Control Circuit Voltage (Uc)50 Hz 48 ... 130 V
Rated Control Circuit Voltage (Uc)60 Hz 48 ... 130 V
Rated Control Circuit Voltage (Uc)DC Operation 48 ... 130 V
Coil ConsumptionHolding at Max. Rated Control Circuit Voltage 50 Hz 10 V·A
Coil ConsumptionHolding at Max. Rated Control Circuit Voltage 60 Hz 10 V·A
Coil ConsumptionHolding at Max. Rated Control Circuit Voltage DC 2 W
Coil ConsumptionPull-in at Max. Rated Control Circuit Voltage 50 Hz 470 V·A
Coil ConsumptionPull-in at Max. Rated Control Circuit Voltage 60 Hz 470 V·A
Coil ConsumptionPull-in at Max. Rated Control Circuit Voltage DC 520 W
Power Lossat Rated Operating Conditions per Pole 18 W
Operate TimeBetween Coil De-energization and NC Contact Closing 40 ... 50 ms
Operate TimeBetween Coil De-energization and NO Contact Opening 43 ... 53 ms
Operate TimeBetween Coil Energization and NC Contact Opening 45 ... 85 ms
Operate TimeBetween Coil Energization and NO Contact Closing 50 ... 90 ms
Connecting Capacity Main CircuitBar 32 mm²
Connecting Capacity Main CircuitRigid Al-Cable 2 x 95 ... 120 mm²
Connecting Capacity Main CircuitRigid Cu-Cable 16 ... 240 mm²
Connecting Capacity Auxiliary CircuitFlexible with Ferrule 2x 0.75 ... 2.5 mm²
Connecting Capacity Auxiliary CircuitFlexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Connecting Capacity Auxiliary CircuitFlexible 2x0.75 ... 2.5 mm²
Connecting Capacity Auxiliary CircuitSolid 2 x 1 ... 4 mm²
Connecting Capacity Auxiliary CircuitStranded 2 x 1 .... 4 mm²
Connecting CapacityBar 32 mm²
Connecting CapacityRigid Al-Cable 2 x 95 ... 120 mm²
Connecting CapacityRigid Cu-Cable 16 ... 240 mm²
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Connecting Terminals (delivered in open position) Main PolesFlat type c/w screws and bolts
Tightening torqueMain Circuit 28 N·m
Terminal TypeRing-Tongue Terminals
Product NameBlock Contactor

Technical UL/CSA

Maximum Operating Voltage UL/CSAMain Circuit 600 V
General Use Rating UL/CSA(600 V AC) 400 A
Horsepower Rating UL/CSA(200 V AC) Three Phase 100 hp
Horsepower Rating UL/CSA(208 V AC) Three Phase 100 hp
Horsepower Rating UL/CSA(220 ... 240 V AC) Three Phase 100 hp
Horsepower Rating UL/CSA(440 ... 480 V AC) Three Phase 250 hp
Horsepower Rating UL/CSA(550 ... 600 V AC) Three Phase 300 hp
Full Load Amps Motor Use(440 ... 480 V AC) Three Phase 302 A
Full Load Amps Motor Use(550 ... 600 V AC) Three Phase 289 A

Why Proax for ABB AF300B-30-11RT-69?

Proax is an authorized distributor of ABB AF300B-30-11RT-69 and one of ABB's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Alternate NamesAF300B3011RT69
Pack Size1
Recommended

CAD$3,610.89

Not in stock

Request lead time or order—we'll ensure quick delivery

ABB Availability