Proax

Currency
0 Items
proax logo
Cart
Phoenix ContactOfficial Distributor

By Phoenix Contact

SKU
MPN
SACCEC-M12FSD-4CON-M16/1,0-931
Weight
0.068 kg
Series SACCEC-M

SACCEC-M12FSD-4CON-M16/1,0-931 - Device connector front mounting

Device connector front mounting, Ethernet CAT5 (100 Mbps), Ethernet, 4-position, PUR, water blue RAL 5021, shielded, Socket, straight, M12, coding: D, on free cable end, Front mounting, Cable lug connection, cable length: 1 m, Ethernet flexible CAT5, 2-pair, Alternative product in accordance with RoHS II without Exemption 6c (Pb < 0.1 %) item no.: 1239910

  • Preassembled with cables in various standard lengths for immediate use
  • Customer-specific assemblies and cable lengths can be supplied
  • Sealed on the cable side for optimum tightness of seal
  • Cable designs for all common networks and fieldbuses
  • For high transmission safety: shield connection to the housing with optional EMC nut
Technical Specifications

Notes

Notes on operationThe electrical and mechanical data specified assume that the connector pair is correctly locked and mounted. If the connector is unlocked and if there is a danger of contamination, the connector must be sealed using a protective cap > IP54. Influences arising from litz wires, cables or PCB assembly must also be taken into consideration.
Order information:Lock nut is included in the scope of delivery

Safety note

Safety noteWARNING: The connectors may not be plugged in or disconnected under load. Ignoring the warning or improper use may damage persons and/or property.
Safety note• WARNING: Commission properly functioning products only. The products must be regularly inspected for damage. Decommission defective products immediately. Replace damaged products. Repairs are not possible.
Safety note• WARNING: Only electrically qualified personnel may install and operate the product. They must observe the following safety notes. The qualified personnel must be familiar with the basics of electrical engineering. They must be able to recognize and prevent danger. The relevant symbol on the packaging indicates that only personnel familiar with electrical engineering are allowed to install and operate the product.
Safety note• The products are suitable for applications in plant, controller, and electrical device engineering.
Safety note• When operating the connectors in outdoor applications, they must be separately protected against environmental influences.
Safety note• Assembled products may not be manipulated or improperly opened.
Safety note• Only use mating connectors that are specified in the technical data of the standards listed (e.g. the ones listed in the product accessories online at phoenixcontact.com/products).
Safety note• When using the product in direct connection with third-party manufacturers, the user is responsible.
Safety note• For operating voltages > 50 V AC, conductive connector housings must be grounded
Safety note• Ensure that when laying the cable, the tensile load on the connectors does not exceed the upper limit specified in the standards.
Safety note• Observe the corresponding technical data. You will find information:o On the producto On the packing labelo In the supplied documentationo Online at phoenixcontact.com/products under the product
Safety note• Only use tools recommended by Phoenix Contact
Safety note• Use a protective cap to protect connectors that are not in use. The suitable accessories are available online in the accessory section of the product at phoenixcontact.com/products
Safety note• Ensure that the protective or functional ground has been properly connected.
Safety note• VDE 0100/1.97 § 411.1.3.2 and DIN EN 60 204/11.98 § 14.1.3 are applicable when combining several circuits in a cable and/or connector
Safety note• The connector warms up in normal operation. Depending on the ambient conditions, the surface of the connector can continue to warm up. In this case, the user is responsible for posting warnings (e.g. DIN EN ISO 13732-1:2008-12).

Mounting

Mounting TypeFront mounting

Product properties

Sensor TypeEthernet
Number of Positions4
No. of cable outlets1
Shieldedyes
CodingD
Thread typeM12

Insulation characteristics

Overvoltage categoryII
Degree of pollution3

Material specifications

Flammability rating according to UL 94V0
Seal materialNBR
Contact MaterialCuZn
Contact surface materialNi/Au
Contact carrier materialPA 6.6
Material for screw connectionBrass, nickel-plated
Outer sheath, materialPUR

Electrical properties

Contact resistance≤ 3 mΩ
Insulation resistance≥ 100 MΩ
Nominal voltage UN48 V AC
Nominal voltage UN60 V DC
Nominal current IN4 A (Plug/socket in accordance with IEC 61076-2-101, cable technical data is to be observed)
Test voltage2500 V
Transmission mediumCopper
Transmission characteristics (category)CAT5 (IEC 11801:2002)

Conductor connection

Connection MethodCable lug connection
Contact connection typeSocket

Connection 1

Head designSocket
Head cable outletstraight
Head thread typeM12
CodingD

Connection 2

Head designfree cable end

Cable/line

Cable Length1 m

Ethernet flexible CAT5, 2-pair [93E]

Cable weight42 kg/km
UL AWM style20963 (80°C/30 V)
Wiring standards/regulationsElectrical requirements EN 50288-2-2
Number of Positions4
Shieldedyes
Cable TypeEthernet flexible CAT5, 2-pair [93E]
Conductor structure2x2xAWG26/7, SF/UTP
Signal runtime5.3 ns/m
Conductor structure signal line7x 0.16 mm
AWG Signal Line26
Conductor Cross Section2x 2x 0.14 mm²
Wire diameter incl. insulation0.98 mm
External Cable Diameter6.40 mm ±0.2 mm
Outer sheath, materialPUR
External sheath, colorwater blue RAL 5021
Conductor materialBare Cu litz wires
Material wire insulationFoamed PE
Single wire, colorwhite/orange-orange, white/green-green
Thickness, outer sheath1.20 mm
Twisted pairs2 cores to the pair
Overall twistTwo pairs with two fillers to the core
Optical shield covering70 %
Insulation resistance≥ 500 MΩ*km
Coupling resistance≤ 100.00 mΩ/m (at 10 MHz)
Loop resistance≤ 290.00 Ω/km
Wave impedance100 Ω ±5 Ω (at 100 MHz)
Cable capacityapprox. 45 nF/km (at 1 kHz)
Nominal voltage, cable≤ 100 V (Peak value, not for high-power applications)
Test voltage Core/Core700 V (50 Hz, 1 min.)
Test voltage Core/Shield700.00 V (50 Hz, 1 min.)
Current carrying capacity of cable2.00 A (according to DIN VDE 0891-1)
Minimum bending radius, fixed installation4 x D
Minimum bending radius, flexible installation8 x D
Smallest bending radius, fixed installation26 mm
Smallest bending radius, movable installation52 mm
Tensile strength≤ 80 N
Near end crosstalk attenuation (NEXT)65.3 dB (with 1 MHz)
Near end crosstalk attenuation (NEXT)56.3 dB (at 4 МHz)
Near end crosstalk attenuation (NEXT)50.3 dB (at 10 MHz)
Near end crosstalk attenuation (NEXT)47.2 dB (at 16 MHz)
Near end crosstalk attenuation (NEXT)45.8 dB (at 20 МHz)
Near end crosstalk attenuation (NEXT)42.9 dB (at 31.25 МHz)
Near end crosstalk attenuation (NEXT)38.4 dB (at 62.5 МHz)
Near end crosstalk attenuation (NEXT)35.3 dB (at 100 MHz)
Power-summated near end crosstalk attenuation (PSNEXT)62.3 dB (with 1 MHz)
Power-summated near end crosstalk attenuation (PSNEXT)53.3 dB (at 4 МHz)
Power-summated near end crosstalk attenuation (PSNEXT)47.3 dB (at 10 MHz)
Power-summated near end crosstalk attenuation (PSNEXT)44.2 dB (at 16 MHz)
Power-summated near end crosstalk attenuation (PSNEXT)42.8 dB (at 20 МHz)
Power-summated near end crosstalk attenuation (PSNEXT)39.9 dB (at 31.25 МHz)
Power-summated near end crosstalk attenuation (PSNEXT)35.4 dB (at 62.5 МHz)
Power-summated near end crosstalk attenuation (PSNEXT)32.3 dB (at 100 MHz)
Return attenuation (RL)23 dB (at 4 МHz)
Return attenuation (RL)24.1 dB (at 8 МHz)
Return attenuation (RL)25 dB (at 10 MHz)
Return attenuation (RL)25 dB (at 16 MHz)
Return attenuation (RL)25 dB (at 20 МHz)
Return attenuation (RL)23.6 dB (at 31.25 МHz)
Return attenuation (RL)21.5 dB (at 62.5 МHz)
Return attenuation (RL)20.1 dB (at 100 MHz)
Shield attenuation3.2 dB (with 1 MHz)
Shield attenuation6 dB (at 4 МHz)
Shield attenuation9.5 dB (at 10 MHz)
Shield attenuation12.1 dB (at 16 MHz)
Shield attenuation13.6 dB (at 20 МHz)
Shield attenuation17.1 dB (at 31.25 МHz)
Shield attenuation24.8 dB (at 62.5 МHz)
Shield attenuation32 dB (at 100 MHz)
Halogen-freeaccording to IEC 60754-1
Flame resistanceaccording to IEC 60332-1-2
Flame resistancein acc. to UL VW1
Flame resistancein accordance with UN ECE-R 118.03
Resistance to Oilin accordance with EN 60811-2-1
Ambient Temperature (Operation)-40 °C ... 80 °C (cable, fixed installation)
Ambient Temperature (Operation)-20 °C ... 80 °C (Cable, flexible installation)
Ambient temperature (installation)-20 °C ... 80 °C

Ambient conditions

Degree of ProtectionIP67
Degree of ProtectionIP65/IP67
Ambient Temperature (Operation)-25 °C ... 85 °C (Plug / socket)
Ambient Temperature (Operation)-40 °C ... 85 °C (without mechanical actuation)

M12

Standard designationM12 connector
Standards/specificationsIEC 61076-2-101
Accessories

Why Proax for Phoenix Contact 1528497?

Proax is an authorized distributor of Phoenix Contact 1528497 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Pack Size1
Recommended

Not in stock

Request lead time or order—we'll ensure quick delivery

Phoenix Contact Availability