1624130
SKU
PHX1624130
MPN
EV-PLCC-AC1-DC1
Weight
1.139 kg
This product is Not Cancellable/Not Returnable
EV-PLCC-AC1-DC1 - DC charging controller
Programmable charging controller for DC and AC charging of electric vehicles in accordance with IEC 61851-1,-23, DIN SPEC 70121, and CHAdeMO, with integrated cellular modem
Technical Specifications
Utilization restriction
| EMC note | EMC: class A product, see manufacturer's declaration in the download area |
Digital
| Number of digital inputs | 16 |
| Connection Method | COMBICON connectors |
| Description of the input | EN 61131-2 type 1 |
| Input voltage range | -0.5 V DC ... 30 V DC |
| Input voltage range | -0.5 V DC ... 5 V DC (“0” signal) |
| Input voltage range | 15 V DC ... 30 V DC (“1” signal) |
| Typical response time | min. 3 ms |
| Cable Length | max. 30 m |
Output data
| Resistance to permanent reverse voltage | max. 500 mA |
Digital
| Connection Method | COMBICON connectors |
| Number outputs | 16 |
| Output Voltage | 24 V DC |
| Maximum Output Current per channel | 500 mA |
Switching
| Output name | AC charging locking system |
| Maximum output current | max. 2 A |
| Maximum output voltage | 12 V DC (Internal supply) |
Energy storage
| Battery | integrated (rechargeable battery buffered) |
Conductor connection
| Connection Method | COMBICON connectors |
| Conductor cross section rigid | 0.08 mm² ... 1.5 mm² |
| Conductor cross section flexible | 0.08 mm² ... 1.5 mm² |
| Conductor cross section AWG | 28 ... 16 |
Interfaces
| Interface | Ethernet (2x) |
Wireless
| Interface description | 3G / 2G |
| Note | Hardware revision 02 or later |
| Frequency | 900 MHz (GSM/GPRS/EDGE ) |
| Frequency | 1800 MHz (GSM/GPRS/EDGE ) |
| Frequency | 850 MHz (UMTS/HSPA (Class 3)) |
| Frequency | 1900 MHz (UMTS/HSPA (Class 3)) |
| Frequency | 2100 MHz (UMTS/HSPA (Class 3)) |
| Connection Method | SMA (female) |
| Impedance | 50 Ω |
| Antenna | max. cable length of 30 m |
| SIM Interface | 1.8 volt and 3 volt SIM card |
| GPRS | Class 12, Class B |
| EDGE | Multislot Class 10 |
| UMTS | HSPA 3GPP R6 |
| Protocols Supported | OCPP 1.6J (Core-Profile) |
| Interface description | 4G / 2G |
| Note | Hardware revision 04 or later |
| Frequency | 900 MHz (GSM/GPRS/EDGE ) |
| Frequency | 1800 MHz (GSM/GPRS/EDGE ) |
| Frequency | 800 MHz (LTE B20) |
| Frequency | 900 MHz (LTE B8) |
| Frequency | 1800 MHz (LTE B3) |
| Frequency | 2100 MHz (LTE B1) |
| Frequency | 2600 MHz (LTE B7) |
| Frequency | 700 MHz (LTE B28) |
| Connection Method | SMA (female) |
| Impedance | 50 Ω |
| Antenna | max. cable length of 30 m |
| SIM Interface | 1.8 volt and 3 volt SIM card |
| GPRS | Class 12, Class B |
| EDGE | Multislot Class 10 |
| LTE | CAT1, CAT4 |
| Protocols Supported | OCPP 1.6J (Core-Profile) |
DC charging
| Standards/regulations | IEC 61851-1 |
| Standards/regulations | IEC 61851-23 |
| Charging mode | Mode 4 |
| Communication | DIN SPEC 70121 |
| Cable Length | max. 10 m |
| Proximity | Analog input, reserved for future applications |
| Temperature sensors | 2x Pt 1000 |
| Temperature Range | -20 °C ... 120 °C |
| Relay output | DC charging enabled |
| Maximum Switching Voltage | 30 V (External supply) |
| Max. switching current | 6 A (External supply) |
AC charging
| Standards/regulations | IEC 61851-1, Annex A+B |
| Charging mode | Mode 3, Case B + C |
| Locking control | Relay output, supplied internally |
| Locking feedback | Resistance measurement |
| Voltage | ± 12 V |
| Maximum current for locking actuators | 2 A |
| Activation time | Can be set via application program |
| Behavior in the event of voltage drop | Automatic unlocking |
| Switching thresholds | Can be set via application program |
| Temperature sensors | 1x Pt 1000 (evaluation via application program) |
| Temperature Range | -20 °C ... 120 °C |
| Relay output | AC charging enabled |
| Maximum Switching Voltage | 30 V (External supply) |
| Max. switching current | 6 A (External supply) |
RS-485
| Interface | RS-485 2-wire |
| Connection Method | COMBICON connectors |
| Number of interfaces | 2 |
| Transmission length | max. 3 m (with shielded cable max. 30 m) |
| Termination resistor | 120 Ω (Can be connected internally) |
RS-232
| Interface | RS-232 |
| Connection Method | COMBICON connectors |
| Number of interfaces | 2 |
| Transmission length | max. 3 m (with shielded cable max. 30 m) |
Ethernet
| Interface | Ethernet |
| Connection Method | RJ45 jack |
| Number of interfaces | 2 |
| Transmission Speed | 100 Mbps |
| Transmission length | max. 100 m |
CAN-Bus
| Interface | CAN bus |
| Connection Method | COMBICON connectors |
| Number of interfaces | 1 (Transparent mode, CAN 2.0a, 11 Bit Object Identifier, CAN 2.0b, 29 Bit Object Identifier) |
| Transmission Speed | 500 kbps (Default) |
| Transmission Speed | 125 kbps, 250 kbps, 1000 kbps (adjustable) |
| Transmission length | max. 3 m (with shielded cable max. 30 m) |
| Termination resistor | 120 Ω (Can be connected internally) |
System properties
| Parameterization memory | min. 4 Mbyte (depending on storage media) |
IEC 61131 runtime system
| Program Memory | 1 Mbyte (86 K instructions (IL)) |
| Data storage system | 1 Mbyte |
| Retentive data storage | 48 kByte (NVRAM) |
| Number of control tasks | 8 |
| Processing Speed | 1.3 ms (1 K mix instructions) |
| Processing Speed | 90 µs (1 K bit instructions) |
Charging controllers
| Application | Programmable charging controller for DC and AC charging of electric vehicles in accordance with IEC 61851-1,-23, DIN SPEC 70121, and CHAdeMO, with integrated cellular modem |
| Type | in housing |
| Number of charging points | 2 |
System requirements
| Engineering tool | PC Worx |
| Diagnostics tool | DIAG+ |
| Runtime system | eCLR |
Supply
| Supply voltage UL | 24 V DC |
| Supply voltage range UM | 24 V DC -15 % / +20 % (in accordance with EN 61131-2) |
| Residual ripple, in reference to the measured value | 5 % |
| Segment circuit supply US | 24 V DC -15 % / +20 % (in accordance with EN 61131-2) |
| Current consumption from UM | max. 8 A DC |
| Current consumption from US | max. 8 A DC |
| Power supply at UL | max. 0.8 A DC |
| Power supply at UM | max. 8 A DC (sum of UM + US) |
| Power supply at US | max. 8 A DC (sum of UM + US) |
Real-time clock
| Realtime Clock | Yes |
Supply
| Supply Voltage | 24 V DC (Length of cable max. 30 m) |
| Supply Voltage Range | 19.2 V DC ... 30 V DC (Incl. all tolerances, incl. residual ripple) |
Product properties
| Product family | CHARX control professional |
| Application | Programmable charging controller for DC and AC charging of electric vehicles in accordance with IEC 61851-1,-23, DIN SPEC 70121, and CHAdeMO, with integrated cellular modem |
| Operating mode | Stand-Alone |
| Operating mode | Client |
| Operating mode | Server |
Dimensions
| Width | 285.00 mm |
| Height | 158.00 mm |
| Depth | 70.00 mm |
Mounting
| Mounting Type | DIN rail mounting |
| Assembly instructions | DIN rail mounting |
| Mounting Position | horizontal |
Ambient conditions
| Degree of Protection | IP20 |
| Ambient Temperature (Operation) | -25 °C ... 55 °C |
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
| Permissible humidity (operation) | 10 % ... 95 % (according to DIN EN 61131-2, non-condensing, no ice formation) |
| Permissible humidity (storage/transport) | 10 % ... 95 % (in accordance with EN 61131-2) |
| Shock (operation) | 25g (Criterion 1, according to IEC 60068-2-27) |
| Vibration (Operation) | 5g |
| Vibration (storage/transport) | 5g |
| Air pressure (operation) | 70 kPa ... 106 kPa (up to 3000 m above mean sea level) |
| Air pressure (storage/transport) | 58 kPa ... 106 kPa (up to 4500 m above mean sea level) |
Standards
| Standards/regulations | IEC 61851-23 |
| Standards/regulations | DIN SPEC 70121 |
| Standards/regulations | CHAdeMO V1.1 |
EMC data
| Conformance with EMC directives | Immunity test in accordance with EN 61000-6-2/IEC 61000-6-2 Electrostatic discharge (ESD)EN 61000-4-2/IEC 61000-4-2 Criterion B, ±4 kV contact discharge, ±8 kV air discharge |
| Conformance with EMC directives | Immunity test in accordance with EN 61000-6-2/IEC 61000-6-2 Electromagnetic fieldsEN 61000-4-3/IEC 61000-4-3 Criterion A, Field intensity: 10 V/m |
| Conformance with EMC directives | Immunity test in accordance with EN 61000-6-2/IEC 61000-6-2 Fast transients (burst)EN 61000-4-4/IEC 61000-4-4 Criterion B, ±2 kV |
| Conformance with EMC directives | Immunity test in accordance with EN 61000-6-2/IEC 61000-6-2 Transient overvoltage (surge)EN 61000-4-5/IEC 61000-4-5 Criterion B, Supply lines: 1 kV, Signal/data lines: 0,5 kV |
| Conformance with EMC directives | Immunity test in accordance with EN 61000-6-2/IEC 61000-6-2 Conducted interferenceEN 61000-4-6/IEC 61000-4-6 Criterion A, Test voltage 10 V |
| Conformance with EMC directives | Noise emission test in accordance with EN 61000-6-4/IEC 61000-6-4 EN 55011 Class A |
Accessories
Why Proax for Phoenix Contact 1624130?
Proax is an authorized distributor of Phoenix Contact 1624130 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
| Pack Size | 1 |