GAF460-10-11-69
By ABB
Contactors for DC switching
GF, GAF, and GA contactors are engineered specifically for switching DC circuits up to 1500 V. These contactors are designed to efficiently break DC circuits, making them one of the most compact solutions on the market. Ideal for applications such as PV solar systems, EV charging stations, UPS, and energy storage systems. Additionally, ABB's standard AF contactor range is suitable for DC switching up to 850 V DC.
Product Benefits:
Compact and Modern: Space-saving design for efficient integration.
Global Compatibility: IEC and UL approved for worldwide use.
Reliable Performance: Suitable for diverse network environments.
Global Support: Access support and use the same products anywhere.
Product Features:
High Current and Voltage Handling:
Up to 1050 A, 1500 V DC-PV3 for PV solar applications.
Up to 2050 A, 1000 V DC-1 for other DC applications.
Proven AF Technology: GF and GAF contactors utilize reliable AF technology.
Versatile Control Voltage: Wide range from 100-250 V AC/DC.
Easy Integration: PLC interface with 24 V DC - 100 mA compatibility.
Built-in Protection: Surge suppression included for enhanced safety.
Dimensions
| Product Net Width | 186 mm |
| Product Net Depth / Length | 216 mm |
| Product Net Height | 278 mm |
| Product Net Weight | 10.6 kg |
| Dimension Diagram | 53540919-59 |
Technical
| Number of Main Contacts NO | 1 |
| Number of Main Contacts NC | 0 |
| Number of Auxiliary Contacts NO | 1 |
| Number of Auxiliary Contacts NC | 1 |
| Number of Poles | 1P |
| Rated Operational Voltage | Main Circuit 1000 V |
| Conventional Free-air Thermal Current (Ith) | acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 700 A |
| Rated Operational Current DC-1 (Ie) | (1000 V) 3 Poles in Series, 40 °C 700 A |
| Rated Operational Current DC-1 (Ie) | (1000 V) 3 Poles in Series, 55 °C 600 A |
| Rated Operational Current DC-1 (Ie) | (1000 V) 3 Poles in Series, 70 °C 480 A |
| Rated Operational Current DC-1 (Ie) | (220 V) 3 Poles in Series, 40 °C 700 A |
| Rated Operational Current DC-1 (Ie) | (220 V) 3 Poles in Series, 55 °C 600 A |
| Rated Operational Current DC-1 (Ie) | (220 V) 3 Poles in Series, 70 °C 480 A |
| Rated Operational Current DC-1 (Ie) | (400 V) 3 Poles in Series, 40 °C 700 A |
| Rated Operational Current DC-1 (Ie) | (400 V) 3 Poles in Series, 55 °C 600 A |
| Rated Operational Current DC-1 (Ie) | (400 V) 3 Poles in Series, 70 °C 480 A |
| Rated Operational Current DC-1 (Ie) | (600 V) 3 Poles in Series, 40 °C 700 A |
| Rated Operational Current DC-1 (Ie) | (600 V) 3 Poles in Series, 55 °C 600 A |
| Rated Operational Current DC-1 (Ie) | (600 V) 3 Poles in Series, 70 °C 480 A |
| Short-Circuit Protective Devices | gG Type Fuses 800 A |
| Rated Insulation Voltage (Ui) | acc. to UL/CSA 1000 V |
| Rated Impulse Withstand Voltage (Uimp) | Main Circuit 8 kV |
| Mechanical Durability | 3 million |
| Maximum Mechanical Switching Frequency | 300 cycles per hour |
| Coil Operating Limits | (acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C) |
| Rated Control Circuit Voltage (Uc) | 50 Hz 48 ... 130 V |
| Rated Control Circuit Voltage (Uc) | 60 Hz 48 ... 130 V |
| Rated Control Circuit Voltage (Uc) | DC Operation 48 ... 130 V |
| Coil Consumption | Holding at Max. Rated Control Circuit Voltage 50 Hz 12 V·A |
| Coil Consumption | Holding at Max. Rated Control Circuit Voltage 60 Hz 12 V·A |
| Coil Consumption | Holding at Max. Rated Control Circuit Voltage DC 7.5 V·A |
| Coil Consumption | Holding at Max. Rated Control Circuit Voltage DC 4 W |
| Coil Consumption | Pull-in at Max. Rated Control Circuit Voltage 50 Hz 890 V·A |
| Coil Consumption | Pull-in at Max. Rated Control Circuit Voltage 60 Hz 890 V·A |
| Coil Consumption | Pull-in at Max. Rated Control Circuit Voltage DC 990 V·A |
| Power Loss | at Rated Operating Conditions per Pole 42 W |
| Connecting Capacity Main Circuit | Bar 47 mm² |
| Connecting Capacity Main Circuit | Rigid Al-Cable 240 mm² |
| Connecting Capacity Main Circuit | Rigid Al-Cable 2x240 mm² |
| Connecting Capacity Main Circuit | Rigid Cu-Cable 240 mm² |
| Connecting Capacity Main Circuit | Rigid Cu-Cable 2x240 mm² |
| Connecting Capacity Auxiliary Circuit | Flexible with Ferrule 1x 0.75 ... 2.5 mm² |
| Connecting Capacity Auxiliary Circuit | Flexible with Ferrule 2x 0.75 ... 2.5 mm² |
| Connecting Capacity Auxiliary Circuit | Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² |
| Connecting Capacity Auxiliary Circuit | Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm² |
| Connecting Capacity Auxiliary Circuit | Flexible 2x0.75 ... 2.5 mm² |
| Connecting Capacity Auxiliary Circuit | Solid 2 x 1 ... 4 mm² |
| Connecting Capacity Auxiliary Circuit | Stranded 2 x 1 .... 4 mm² |
| Connecting Capacity | Bar 47 mm² |
| Connecting Capacity | Rigid Al-Cable 2x240 mm² |
| Connecting Capacity | Rigid Cu-Cable 2x240 mm² |
| Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 |
| Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00 |
| Connecting Terminals (delivered in open position) Main Poles | M 3.5 (+,-) pozidriv 2 screw with cable clamp |
| Recommended Screw Driver | Main Circuit M10 |
| Recommended Screw Driver | Control Circuit Pozidriv 2 |
| Recommended Screw Driver | Control Circuit M3.5 |
| Tightening torque | Cable Lug 35 N·m |
| Tightening torque | Main Circuit 35 N·m |
| Terminal Type | Main Circuit: Bars |
| Suitable for Product Class | Block ContactorsBlock Contactors |
| Product Name | Block Contactor |
Technical UL/CSA
| Horsepower Rating NEMA | (200 V AC) Three Phase 150 Hp |
| Horsepower Rating NEMA | (230 V AC) Three Phase 200 Hp |
| Horsepower Rating NEMA | (460 V AC) Three Phase 400 Hp |
| Maximum Operating Voltage UL/CSA | Main Circuit 1000 V |
| General Use Rating UL/CSA | (1000 V DC) 650 A |
| General Use Rating UL/CSA | (440 V DC) 650 A |
| General Use Rating UL/CSA | (600 V AC) 650 A |
| General Use Rating UL/CSA | (600 V DC) 650 A |
ABB EcoSolutions
| End Of Life Disassembling Instructions | 1SFC100112M0003 |
| Environmental Product Declaration - EPD | 1SFC100105D0201 |
Why Proax for ABB GAF460-10-11-69?
Proax is an authorized distributor of ABB GAF460-10-11-69 and one of ABB's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
| Alternate Names | GAF460101169 |
| Pack Size | 1 |