CAL4-11 is a 2-pole side mounted auxiliary contact block equipped with screw terminals and can be fitted on AF(C)09(Z)(B)...96 contactors and NF(C)(Z)(B) contactor relays. CAL4 auxiliary contact block can be clipped onto the right- and/or left-hand side of the contactors or the contactor relays and bears the corresponding function marking. CAL4-11 is available with 1 N.O. and 1 N.C. instantaneous contacts for standard industrial environments.
Technical Specifications
Dimensions
Product Net Width | 12 mm |
Product Net Depth / Length | 60 mm |
Product Net Height | 69.4 mm |
Product Net Weight | 0.04 kg |
Technical
Number of Auxiliary Contacts NO | 1 |
Number of Auxiliary Contacts NC | 1 |
Standards | IEC/EN 60947-5-1, UL 60947-5-1, CSA C22.2 No. 60947-5-1-14 |
Rated Operational Voltage | Auxiliary Circuit 690 V |
Rated Frequency (f) | Auxiliary Circuit 50 / 60 Hz |
Conventional Free-air Thermal Current (Ith) | acc. to IEC 60947-5-1, Θ = 40 °C 16 A |
Rated Operational Current AC-15 (Ie) | (500 V) 2 A |
Rated Operational Current AC-15 (Ie) | (690 V) 2 A |
Rated Operational Current AC-15 (Ie) | (24 / 127 V) 6 A |
Rated Operational Current AC-15 (Ie) | (220 / 240 V) 4 A |
Rated Operational Current AC-15 (Ie) | (400 / 440 V) 3 A |
Rated Short-time Withstand Current Low Voltage (Icw) | for 0.1 s 140 A |
Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 100 A |
Maximum Electrical Switching Frequency | (AC-15) 1200 cycles per hour |
Maximum Electrical Switching Frequency | (DC-13) 900 cycles per hour |
Rated Operational Current DC-13 (Ie) | (24 V) 6 A / 144 W |
Rated Operational Current DC-13 (Ie) | (48 V) 2.8 A / 134 W |
Rated Operational Current DC-13 (Ie) | (72 V) 1 A / 72 W |
Rated Operational Current DC-13 (Ie) | (110 V) 0.55 A / 60 W |
Rated Operational Current DC-13 (Ie) | (125 V) 0.55 A / 69 W |
Rated Operational Current DC-13 (Ie) | (220 V) 0.27 A / 60 W |
Rated Operational Current DC-13 (Ie) | (250 V) 0.27 A / 68 W |
Rated Operational Current DC-13 (Ie) | (400 V) 0.15 A / 60 W |
Rated Operational Current DC-13 (Ie) | (500 V) 0.13 A / 65 W |
Rated Operational Current DC-13 (Ie) | (600 V) 0.1 A / 60 W |
Rated Insulation Voltage (Ui) | acc. to IEC 60947-5-1 690 V |
Rated Insulation Voltage (Ui) | acc. to UL/CSA 600 V |
Rated Impulse Withstand Voltage (Uimp) | 6 kV |
Maximum Mechanical Switching Frequency | 3600 cycles per hour |
Connecting Capacity Auxiliary Circuit | Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² |
Connecting Capacity Auxiliary Circuit | Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² |
Connecting Capacity Auxiliary Circuit | Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² |
Connecting Capacity Auxiliary Circuit | Rigid Solid 1/2x 1 ... 2.5 mm² |
Connecting Capacity Auxiliary Circuit | Rigid Stranded 1/2x 1 ... 2.5 mm² |
Wire Stripping Length | Auxiliary Circuit 10 mm |
Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20 |
Terminal Type | Screw Terminals |
Suitable for | AF09 |
Suitable for | AF09Z |
Suitable for | AF12 |
Suitable for | AF12Z |
Suitable for | AF16 |
Suitable for | AF16Z |
Suitable for | AF26 |
Suitable for | AF26Z |
Suitable for | AF30 |
Suitable for | AF30Z |
Suitable for | AF38 |
Suitable for | AF38Z |
Suitable for | AF40 |
Suitable for | AF52 |
Suitable for | AF65 |
Suitable for | AF80 |
Suitable for | AF96 |
Suitable for | AFC09 |
Suitable for | AFC12 |
Suitable for | AFC16 |
Suitable for | AFC26 |
Suitable for | AFC30 |
Suitable for | AFC38 |
Suitable for | AFC40 |
Suitable for | AFC52 |
Suitable for | AFC65 |
Suitable for | AFC80 |
Suitable for | AFC96 |
Suitable for | AFS09 |
Suitable for | AFS12 |
Suitable for | AFS16 |
Suitable for | AFS26 |
Suitable for | AFS30 |
Suitable for | AFS38 |
Suitable for | AFS40 |
Suitable for | AFS52 |
Suitable for | AFS65 |
Suitable for | AFS80 |
Suitable for | AFS96 |
Suitable for | AF09B |
Suitable for | AF09ZB |
Suitable for | AF12B |
Suitable for | AF12ZB |
Suitable for | AF16B |
Suitable for | AF16ZB |
Suitable for | AF26B |
Suitable for | AF26ZB |
Suitable for | AF30B |
Suitable for | AF30ZB |
Suitable for | AF38B |
Suitable for | AF38ZB |
Suitable for | AF40B |
Suitable for | AF52B |
Suitable for | AF65B |
Suitable for | AF80B |
Suitable for | AF96B |
Suitable for | NF22E |
Suitable for | NFZ22E |
Suitable for | NF31E |
Suitable for | NFZ31E |
Suitable for | NF40E |
Suitable for | NFZ40E |
Suitable for | NF44E |
Suitable for | NFZ44E |
Suitable for | NF53E |
Suitable for | NFZ53E |
Suitable for | NF62E |
Suitable for | NFZ62E |
Suitable for | NF71E |
Suitable for | NFZ71E |
Suitable for | NF80E |
Suitable for | NFZ80E |
Suitable for | NF33/11 |
Suitable for | NF51/11 |
Suitable for | NFC22E |
Suitable for | NFC31E |
Suitable for | NFC40E |
Suitable for | NFC44E |
Suitable for | NFC53E |
Suitable for | NFC62E |
Suitable for | NFC71E |
Suitable for | NFC80E |
Suitable for | NFC33/11 |
Suitable for | NFC51/11 |
Suitable for | NFZB22E |
Suitable for | NFB22E |
Suitable for | NFZB31E |
Suitable for | NFB31E |
Suitable for | NFZB40E |
Suitable for | NFB40E |
Suitable for | NFZB44E |
Suitable for | NFB44E |
Suitable for | NFZB62E |
Suitable for | NFB62E |
Suitable for | NFZB80E |
Suitable for | NFB80E |
Technical UL/CSA
Connecting Capacity Auxiliary Circuit UL/CSA | Rigid Solid 1/2x 18-14 AWG |
Connecting Capacity Auxiliary Circuit UL/CSA | Rigid Stranded 1/2x 18-14 AWG |
Tightening Torque UL/CSA | Auxiliary Circuit 11 in·lb |
Why Proax for ABB CAL4-11?
Proax is an authorized distributor of ABB CAL4-11 and one of ABB's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Alternate Names | CAL411 |
Pack Size | 1 |