Proax

Currency
0 Items
proax logo
Cart
CCSOfficial Distributor

By CCS

SKU
Series PD3
This Digital Control Unit can be used for LED Light Units with an input voltage of 24 V within a total power consumption of 46 W. Connection with the HLV3/HLV2-series Spot Lights is also available. It operates with 24 VDC input. It measures 197 x 82.6 x 120 mm (width x depth x height). External control through Parallel communications.
Technical Specifications

DimensionsW 197 mm x D 82.6 mm x H 120 mm
Applicable Light Unit (output ratings)Light Units with 24 VDC input, HLV3/HLV2 series (Spot Light) Total for 4 channels: 46 W
Number of channels4 channels
Lighting MethodConstant/Strobe lighting
Drive Method24V LIGHT connectors: Constant-voltage system, HLV LIGHT connectors: Constant-current system
Intensity control method24V LIGHT connectors: PWM control and lighting time control, HLV LIGHT connectors: Variable-current control
PWM frequency125kHz
Input Voltage24 VDC (21.6 to 26.4 V)
Frequency50/60 Hz
Power consumption52 W
Output Voltage24VDC
Output CurrentTotal for 4 channels: 1.91 A
Intensity controlManual: 256-step using the front setting switch External: 8-bit input (B0 to B7), write pulse (BRTWR), and channel selection (CHSEL0 to CHSEL2)

Error detection displayDigital display on the front-panel; OCP: Overcurrent error, EFN: Fan Stop Error, and EID: ID error (HLV3/HLV2-series Spot Lights only)
Error detection outputNPN transister output to the External control connector pins between 19(OC) and 20(OE); open for normal operation, closed for overcurrent detection.
Over current protectionOperates at 107% of rated output current or higher. Reset by pressing operation setting switch for at least 1 second or by cycling the power supply. *Do not intentionally short-circuit the positive and negative output terminals.
Output connectorSMP-03V-BC x 8
External control connectorTrigger input: MIL connector (MIL-C-83503 compliant), 10 pins For setting the light intensity/mode: MIL connector (MIL-C-83503 compliant), 20 pins
Conformed standardsCE, UKCA、RoHS
Operating temperature and humidityTemperature: 0 to 40°C, Humidity: 20 to 85%RH (no condensation)
Storage temperature and humidityTemperature: -20 to 60°C, Humidity: 20 to 85%RH (no condensation)
Cooling MethodForced cooling
Weight850 g
MaterialAluminium, ABS
AccessoriesInstruction Guide, Brackets for the PD3-series Control Unit (BK-PD3) (including 2 brackets)

Why Proax for CCS PD3-5024-4-PT(A)?

Proax is the authorized distributor of CCS PD3-5024-4-PT(A). Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Alternate NamesPD350244PTA
Pack Size1
Recommended

Not in stock

Request lead time or order—we'll ensure quick delivery