The BMU Series features a compact, high-power and high-efficiency brushless DC motor (BLDC motor) and is combined with an easy to use, easy to set speed controller. The entire motor structure features our latest brushless DC motor technology and has been innovated in pursuit of the optimal performance.High-efficiency motorWide Speed Control Range (Max. speed 3,600 r/min)Easy wiring and set upExpanded functionsIP66 rated motor*Connection Cable Required.
Technical Specifications
Motor TypeBrushless DC Motor
Motor Frame Size3.15 in.
Output Power60 W (1/12 HP)
Power SupplySingle-Phase 100-120 VAC
Shaft/Gear TypeRight-Angle Hollow Shaft (Stainless Steel) Gearhead
Gear Ratio (X:1)30 :1
Output Shaft Diameter12 mm
Rated Torque35 lb-in
Electromagnetic BrakeNot Equipped
Variable Speed Range (r/min)2.7 ~ 120
Permissible Load Inertia*When instantaneous stop or instantaneous bi-directional operation is performed = 1640 oz-in²
Permissible Radial Load0.79 in. from Shaft End = 119 lb
Permissible Axial Load39 lb
Max. Extension Length (m)10.50
ComponentsBLM460SHPK-4H30S (Motor)BMUD60-A2 (Driver)
RoHS CompliantThese products do not contain substances that exceed the regulation values in the RoHS Directive.
Safety StandardsUL
CE MarkingLow Voltage Directives
Insulation Resistance (Motor)100 MΩ or more when 500 VDC megger is applied between the windings and the case after continuous operation under normal ambient temperature and humidity.
Insulation Resistance (Driver)100 MΩ or more when a 500 VDC megger is applied between the power supply terminal and the protective earth terminal and between the power supply terminal and the I/O signal terminal after continuous operation under normal ambient temperature and humidity.
Dielectric Strength (Motor)Sufficient to withstand 1.5 kVAC at 50 Hz applied between the windings and the case for 1 minute after continuous operation under normal ambient temperature and humidity.
Dielectric Strength (Driver)No abnormality is judged even with application of 1.5 VAC at 50 Hz between the power supply terminal and the protective earth terminal and with application of 1.5 kVAC at 50 Hz between the power supply terminal and the I/O terminal for 1 minute after continuous operation under normal ambient temperature and humidity.
Temperature Rise (Motor)The maximum temperature rise of the windings is 90ºF (50ºC) and that of the case is 72ºF (40ºC) when measured by the thermocouple method after rated continuous operation under normal ambient temperature and humidity.
Temperature Rise (Driver)Temperature rise of the heat sink is 90ºF (50ºC) or less measured by the thermocouple method after rated continuous operation under normal ambient temperature and humidity.
Ambient temperature range32ºF ~ 104ºF (0ºC ~ 40ºC), nonfreezing
Ambient Humidity85% or less, noncondensing
AltitudeUp to 3300 ft (1000 m) above sea level.
Operating AtmosphereNo corrosive gases or dust. Cannot be used in a radioactive area, magnetic field, vacuum or other special environment.
Thermal ClassCSA standards: 105 (A), EN standards: 120 (E)
Degree of Protection[Motor] IP66[Driver] IP20
Speed Control Method (Select one of the following)Digital Setting using the dial
Number of Speed Settings4
Acceleration/Deceleration TimeAnalog Setting: 0.1 ~ 15.0 s (Time setting from stopped state until reaching rated speed)Common setting for acceleration/deceleration time with the use of acceleration/deceleration time potentiometer*.Digital setting: 0.0 ~ 15.0 s (Time setting from current speed to setting speed)Individual settings for acceleration time/deceleration time for each operating data*.*Acceleration time/deceleration time varies with the load condition of the motor.
Input SignalsPhotocoupler Input method Input Resistance: 5.7 kΩOperation by internal power supply: 5 VDCConnectable External DC Power Supply: 24 VDC -15~+20% Current 100 mA or moreSink input/Source input Supplied through external wiring.Arbitrary signal assignment to X0~X2 input (3 points) is possible [ ]: Initial Setting[FWD], [REV], [MO], ALARM-RESET, EXT-ERROR, H-FREE.
Output SignalsPhotocoupler and Open-Collector OutputExternal Power Supply: 4.5 ~ 30 VDC Current 100 mA or lessSink output/Source output Supplied through external wiring. Arbitrary signal assignment to Y0, Y1 (2 points) is possible [ ]:Initial Setting[ALARM-OUT1], [SPEED-OUT], ALARM-OUT2, MOVE, VA, WNG
Protective FunctionWhen the following protective functions are activated, ALARM-OUT1 output turns OFF and the motor will undergo a coasting stop. At the same time, the alarm code will be displayed. (Instantaneous stop for external stop only)Overcurrent, Main circuit overheating, Overvoltage, Undervoltage, Sensor error, Overload, Overspeed, EEPROM error, Initial sensor error, Initial operation inhibition, External stop
Time RatingContinuous

Why Proax for Oriental Motor BLM460SHPK-4H30S / BMUD60-A2?

Proax is the authorized distributor of Oriental Motor BLM460SHPK-4H30S / BMUD60-A2. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Alternate NamesBLM460SHPK4H30SBMUD60A2
Pack Size1
Recommended

Not in stock

Request lead time or order—we'll ensure quick delivery