ASL09 contactors are mainly used for controlling 3-phase motors and generally for controlling power circuits up to 690 V AC or 220 V DC. They are mainly used for controlling 3-phase motors, non-inductive or slightly inductive loads. The ASL..S contactors are the spring terminal version of the ASL... range. The ASL... series 1-stack 3-pole contactors are of the block type design. - Main poles and auxiliary contact blocks: 3 main poles, 1 built-in auxiliary contact, front-mounted add-on auxiliary contact blocks (mechanically-linked auxiliary contacts compliant with Annex L of IEC 60947-5-1. N.C. mirror contacts compliant with Annex F of IEC 60947-4-1) - Control circuit: DC operated with solid core magnet circuit. The polarity on the coil terminals (A1+ and A2-) must be respected - Accessories: a wide range of accessories is available. ASL... contactors are fitted with low consumption DC coils and are suitable for a direct control by PLC outputs.
Technical Specifications
Dimensions
Product Net Width | 45 mm |
Product Net Depth / Length | 72.5 mm |
Product Net Height | 68 mm |
Product Net Weight | 0.28 kg |
Technical
Number of Main Contacts NO | 3 |
Number of Main Contacts NC | 0 |
Number of Auxiliary Contacts NO | 1 |
Number of Auxiliary Contacts NC | 0 |
Standards | IEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1, UL 508, CSA C22.2 N°14 |
Rated Operational Voltage | Auxiliary Circuit 690 V |
Rated Operational Voltage | Main Circuit 690 V |
Rated Frequency (f) | Auxiliary Circuit 50 / 60 Hz |
Rated Frequency (f) | Main Circuit 50 / 60 Hz |
Conventional Free-air Thermal Current (Ith) | acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 20 A |
Conventional Free-air Thermal Current (Ith) | acc. to IEC 60947-5-1, Θ = 40 °C 10 A |
Rated Operational Current AC-1 (Ie) | (690 V) 40 °C 20 A |
Rated Operational Current AC-1 (Ie) | (690 V) 60 °C 15 A |
Rated Operational Current AC-1 (Ie) | (690 V) 70 °C 12 A |
Rated Operational Current AC-3 (Ie) | (415 V) 60 °C 9 A |
Rated Operational Current AC-3 (Ie) | (440 V) 60 °C 8 A |
Rated Operational Current AC-3 (Ie) | (500 V) 60 °C 8 A |
Rated Operational Current AC-3 (Ie) | (690 V) 60 °C 5 A |
Rated Operational Current AC-3 (Ie) | (380 / 400 V) 60 °C 9 A |
Rated Operational Current AC-3 (Ie) | (220 / 230 / 240 V) 60 °C 9 A |
Rated Operational Power AC-3 (Pe) | (400 V) 4 kW |
Rated Operational Power AC-3 (Pe) | (415 V) 4 kW |
Rated Operational Power AC-3 (Pe) | (440 V) 4 kW |
Rated Operational Power AC-3 (Pe) | (500 V) 4 kW |
Rated Operational Power AC-3 (Pe) | (690 V) 4 kW |
Rated Operational Power AC-3 (Pe) | (220 / 230 / 240 V) 2.2 kW |
Rated Operational Current AC-15 (Ie) | (500 V) NC 2 |
Rated Operational Current AC-15 (Ie) | (500 V) 2 A |
Rated Operational Current AC-15 (Ie) | (690 V) 2 A |
Rated Operational Current AC-15 (Ie) | (24 / 127 V) 6 A |
Rated Operational Current AC-15 (Ie) | (220 / 240 V) 4 A |
Rated Operational Current AC-15 (Ie) | (400 / 440 V) 3 A |
Rated Short-time Withstand Current Low Voltage (Icw) | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 100 A |
Rated Short-time Withstand Current Low Voltage (Icw) | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 20 A |
Rated Short-time Withstand Current Low Voltage (Icw) | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 50 A |
Rated Short-time Withstand Current Low Voltage (Icw) | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 230 A |
Rated Short-time Withstand Current Low Voltage (Icw) | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 65 A |
Rated Short-time Withstand Current Low Voltage (Icw) | for 0.1 s 140 A |
Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 100 A |
Maximum Breaking Capacity | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 155 A |
Maximum Breaking Capacity | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 90 A |
Maximum Electrical Switching Frequency | (AC-1) 600 cycles per hour |
Maximum Electrical Switching Frequency | (AC-15) 1200 cycles per hour |
Maximum Electrical Switching Frequency | (AC-2 / AC-4) 300 cycles per hour |
Maximum Electrical Switching Frequency | (AC-3) 1200 cycles per hour |
Maximum Electrical Switching Frequency | (DC-13) 900 cycles per hour |
Rated Operational Current DC-13 (Ie) | (24 V) 6 A / 144 W |
Rated Operational Current DC-13 (Ie) | (48 V) 2.8 A / 134 W |
Rated Operational Current DC-13 (Ie) | (72 V) 1 A / 72 W |
Rated Operational Current DC-13 (Ie) | (110 V) 0.55 A / 60 W |
Rated Operational Current DC-13 (Ie) | (125 V) 0.55 A / 69 W |
Rated Operational Current DC-13 (Ie) | (220 V) 0.27 A / 60 W |
Rated Operational Current DC-13 (Ie) | (250 V) 0.27 A / 68 W |
Rated Insulation Voltage (Ui) | acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V |
Rated Insulation Voltage (Ui) | acc. to IEC 60947-5-1 and VDE 0110 (Gr. C) 690 V |
Rated Insulation Voltage (Ui) | acc. to UL/CSA 600 V |
Rated Impulse Withstand Voltage (Uimp) | Auxiliary Circuit 6 kV |
Maximum Mechanical Switching Frequency | 3600 cycles per hour |
Rated Control Circuit Voltage (Uc) | DC Operation 24 V |
Operate Time | Between Coil De-energization and NC Contact Closing 15 ... 20 ms |
Operate Time | Between Coil De-energization and NO Contact Opening 13 ... 17 ms |
Operate Time | Between Coil Energization and NC Contact Opening 31 ... 53 ms |
Operate Time | Between Coil Energization and NO Contact Closing 36 ... 59 ms |
Connecting Capacity Main Circuit | Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² |
Connecting Capacity Main Circuit | Flexible with Insulated Ferrule 1/2x 0.75 ... 1.5 mm² |
Connecting Capacity Main Circuit | Rigid 1/2x 0.75 ... 2.5 mm² |
Connecting Capacity Auxiliary Circuit | Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² |
Connecting Capacity Auxiliary Circuit | Flexible with Insulated Ferrule 1/2x 0.75 ... 1.5 mm² |
Connecting Capacity Auxiliary Circuit | Rigid 1/2x 0.75 ... 2.5 mm² |
Connecting Capacity Control Circuit | Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² |
Connecting Capacity Control Circuit | Flexible with Insulated Ferrule 1/2x 0.75 ... 1.5 mm² |
Connecting Capacity Control Circuit | Rigid 1/2x 0.75 ... 2.5 mm² |
Wire Stripping Length | Auxiliary Circuit 10 mm |
Wire Stripping Length | Control Circuit 10 mm |
Wire Stripping Length | Main Circuit 10 mm |
Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20 |
Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 |
Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20 |
Degree of Protection | IP20 |
Terminal Type | Spring Terminals |
Technical UL/CSA
General Use Rating UL/CSA | (600 V AC) 12 A |
Horsepower Rating UL/CSA | (120 V AC) Single Phase 1/3 hp |
Horsepower Rating UL/CSA | (200 ... 208 V AC) Three Phase 2 hp |
Horsepower Rating UL/CSA | (220 ... 240 V AC) Three Phase 2 hp |
Horsepower Rating UL/CSA | (240 V AC) Single Phase 1 hp |
Horsepower Rating UL/CSA | (440 ... 480 V AC) Three Phase 5 hp |
Horsepower Rating UL/CSA | (550 ... 600 V AC) Three Phase 7.5 hp |
Why Proax for ABB ASL09-30-10S-81?
Proax is an authorized distributor of ABB ASL09-30-10S-81 and one of ABB's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Alternate Names | ASL093010S81 |
Pack Size | 40 |
Recommended