ABBOfficial Distributor

By ABB

SKU
MPN
1SBL103001R8101
Weight
0.295 kg
ASL09 contactors are mainly used for controlling 3-phase motors and generally for controlling power circuits up to 690 V AC or 220 V DC. They are mainly used for controlling 3-phase motors, non-inductive or slightly inductive loads. The ASL... series 1-stack 3-pole contactors are of the block type design. - Main poles and auxiliary contact blocks: 3 main poles, 1 built-in auxiliary contact, front-mounted add-on auxiliary contact blocks (mechanically-linked auxiliary contacts compliant with Annex L of IEC 60947-5-1. N.C. mirror contacts compliant with Annex F of IEC 60947-4-1) - Control circuit: DC operated with solid core magnet circuit. The polarity on the coil terminals (A1+ and A2-) must be respected - Accessories: a wide range of accessories is available. ASL... contactors are fitted with low consumption DC coils and are suitable for a direct control by PLC outputs.
Technical Specifications

Dimensions

Product Net Width45 mm
Product Net Depth / Length72.5 mm
Product Net Height68 mm
Product Net Weight0.28 kg

Technical

Number of Main Contacts NO3
Number of Main Contacts NC0
Number of Auxiliary Contacts NO0
Number of Auxiliary Contacts NC1
StandardsIEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1, UL 508, CSA C22.2 N°14
Rated Operational VoltageAuxiliary Circuit 690 V
Rated Operational VoltageMain Circuit 690 V
Rated Frequency (f)Auxiliary Circuit 50 / 60 Hz
Rated Frequency (f)Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 22 A
Conventional Free-air Thermal Current (Ith)acc. to IEC 60947-5-1, Θ = 40 °C 10 A
Rated Operational Current AC-1 (Ie)(690 V) 40 °C 22 A
Rated Operational Current AC-1 (Ie)(690 V) 60 °C 18 A
Rated Operational Current AC-1 (Ie)(690 V) 70 °C 15 A
Rated Operational Current AC-3 (Ie)(415 V) 60 °C 9 A
Rated Operational Current AC-3 (Ie)(440 V) 60 °C 8 A
Rated Operational Current AC-3 (Ie)(500 V) 60 °C 8 A
Rated Operational Current AC-3 (Ie)(690 V) 60 °C 5 A
Rated Operational Current AC-3 (Ie)(380 / 400 V) 60 °C 9 A
Rated Operational Current AC-3 (Ie)(220 / 230 / 240 V) 60 °C 9 A
Rated Operational Power AC-3 (Pe)(400 V) 4 kW
Rated Operational Power AC-3 (Pe)(415 V) 4 kW
Rated Operational Power AC-3 (Pe)(440 V) 4 kW
Rated Operational Power AC-3 (Pe)(500 V) 4 kW
Rated Operational Power AC-3 (Pe)(690 V) 4 kW
Rated Operational Power AC-3 (Pe)(220 / 230 / 240 V) 2.2 kW
Rated Operational Current AC-15 (Ie)(500 V) NC 2
Rated Operational Current AC-15 (Ie)(500 V) 2 A
Rated Operational Current AC-15 (Ie)(690 V) 2 A
Rated Operational Current AC-15 (Ie)(24 / 127 V) 6 A
Rated Operational Current AC-15 (Ie)(220 / 240 V) 4 A
Rated Operational Current AC-15 (Ie)(400 / 440 V) 3 A
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 100 A
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 22 A
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 50 A
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 230 A
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 65 A
Rated Short-time Withstand Current Low Voltage (Icw)for 0.1 s 140 A
Rated Short-time Withstand Current Low Voltage (Icw)for 1 s 100 A
Maximum Breaking Capacitycos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 155 A
Maximum Breaking Capacitycos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 90 A
Maximum Electrical Switching Frequency(AC-1) 600 cycles per hour
Maximum Electrical Switching Frequency(AC-15) 1200 cycles per hour
Maximum Electrical Switching Frequency(AC-2 / AC-4) 300 cycles per hour
Maximum Electrical Switching Frequency(AC-3) 1200 cycles per hour
Maximum Electrical Switching Frequency(DC-13) 900 cycles per hour
Rated Operational Current DC-13 (Ie)(24 V) 6 A / 144 W
Rated Operational Current DC-13 (Ie)(48 V) 2.8 A / 134 W
Rated Operational Current DC-13 (Ie)(72 V) 1 A / 72 W
Rated Operational Current DC-13 (Ie)(110 V) 0.55 A / 60 W
Rated Operational Current DC-13 (Ie)(125 V) 0.55 A / 69 W
Rated Operational Current DC-13 (Ie)(220 V) 0.27 A / 60 W
Rated Operational Current DC-13 (Ie)(250 V) 0.27 A / 68 W
Rated Insulation Voltage (Ui)acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
Rated Insulation Voltage (Ui)acc. to IEC 60947-5-1 and VDE 0110 (Gr. C) 690 V
Rated Insulation Voltage (Ui)acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)Auxiliary Circuit 6 kV
Maximum Mechanical Switching Frequency3600 cycles per hour
Rated Control Circuit Voltage (Uc)DC Operation 24 V
Operate TimeBetween Coil De-energization and NC Contact Closing 15 ... 20 ms
Operate TimeBetween Coil De-energization and NO Contact Opening 13 ... 17 ms
Operate TimeBetween Coil Energization and NC Contact Opening 31 ... 53 ms
Operate TimeBetween Coil Energization and NO Contact Closing 36 ... 59 ms
Connecting Capacity Main CircuitFlexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Connecting Capacity Main CircuitFlexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Connecting Capacity Main CircuitFlexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Connecting Capacity Main CircuitRigid 1/2x 0.75 ... 4 mm²
Connecting Capacity Auxiliary CircuitFlexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Connecting Capacity Auxiliary CircuitFlexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Connecting Capacity Auxiliary CircuitFlexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Connecting Capacity Auxiliary CircuitRigid 1/2x 0.75 ... 2.5 mm²
Connecting Capacity Control CircuitFlexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Connecting Capacity Control CircuitFlexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Connecting Capacity Control CircuitFlexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Connecting Capacity Control CircuitRigid 1/2x 0.75 ... 2.5 mm²
Wire Stripping LengthAuxiliary Circuit 9 mm
Wire Stripping LengthControl Circuit 9 mm
Wire Stripping LengthMain Circuit 9 mm
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
Degree of ProtectionIP20
Terminal TypeScrew Terminals

Technical UL/CSA

General Use Rating UL/CSA(600 V AC) 20 A
Horsepower Rating UL/CSA(120 V AC) Single Phase 1/3 hp
Horsepower Rating UL/CSA(200 ... 208 V AC) Three Phase 2 hp
Horsepower Rating UL/CSA(220 ... 240 V AC) Three Phase 2 hp
Horsepower Rating UL/CSA(240 V AC) Single Phase 1 hp
Horsepower Rating UL/CSA(440 ... 480 V AC) Three Phase 5 hp
Horsepower Rating UL/CSA(550 ... 600 V AC) Three Phase 7.5 hp
Tightening Torque UL/CSAAuxiliary Circuit 9 in·lb
Tightening Torque UL/CSAControl Circuit 9 in·lb
Tightening Torque UL/CSAMain Circuit 9 in·lb

Why Proax for ABB ASL09-30-01-81?

Proax is an authorized distributor of ABB ASL09-30-01-81 and one of ABB's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Alternate NamesASL09300181
Pack Size1
Recommended

Not in stock

Request lead time or order—we'll ensure quick delivery

ABB Availability