The AF80N3-30-11-13 is a 3 pole - 600 V UL, NEMA size N3 contactor with pre-mounted auxiliary contacts and Screw, switching power circuits up to 90 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (100-250 V 50/60 Hz and DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.
Technical Specifications

Dimensions

Product Net Width82 mm
Product Net Depth / Length116 mm
Product Net Height125.5 mm
Product Net Weight1.21 kg

Technical

Number of Main Contacts NO3
Number of Main Contacts NC0
Number of Auxiliary Contacts NO1
Number of Auxiliary Contacts NC1
Number of Poles3P
StandardsIEC/EN 60947-1, IEC/EN 60947-4-1, UL 60335-2-40 LZGH2 A2L, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60335-2-40 LZGH2 A2L, CSA C22.2 No. 60947-1:22, CSA C22.2 No. 60947-4-1:22
Rated Operational VoltageAuxiliary Circuit 690 V
Rated Operational VoltageMain Circuit 1000 V
Rated Frequency (f)Auxiliary Circuit 50 / 60 Hz
Rated Frequency (f)Control Circuit 50 / 60 Hz
Rated Frequency (f)Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 130 A
Conventional Free-air Thermal Current (Ith)acc. to IEC 60947-5-1, Θ = 40 °C 16 A
Rated Operational Current AC-1 (Ie)(690 V) 40 °C 125 A
Rated Operational Current AC-1 (Ie)(690 V) 60 °C 100 A
Rated Operational Current AC-1 (Ie)(690 V) 70 °C 85 A
Rated Operational Current AC-3 (Ie)(415 V) 60 °C 80 A
Rated Operational Current AC-3 (Ie)(440 V) 60 °C 80 A
Rated Operational Current AC-3 (Ie)(500 V) 60 °C 65 A
Rated Operational Current AC-3 (Ie)(690 V) 60 °C 49 A
Rated Operational Current AC-3 (Ie)(1000 V) 60 °C 25 A
Rated Operational Current AC-3 (Ie)(380 / 400 V) 60 °C 80 A
Rated Operational Current AC-3 (Ie)(220 / 230 / 240 V) 60 °C 80 A
Rated Operational Current AC-3e (Ie)(415 V) 60 °C 80 A
Rated Operational Current AC-3e (Ie)(440 V) 60 °C 80 A
Rated Operational Current AC-3e (Ie)(500 V) 60 °C 65 A
Rated Operational Current AC-3e (Ie)(690 V) 60 °C 49 A
Rated Operational Current AC-3e (Ie)(380 / 400 V) 60 °C 80 A
Rated Operational Current AC-3e (Ie)(220 / 230 / 240 V) 60 °C 80 A
Rated Operational Current AC-15 (Ie)(500 V) 2 A
Rated Operational Current AC-15 (Ie)(690 V) 2 A
Rated Operational Current AC-15 (Ie)(24 / 127 V) 6 A
Rated Operational Current AC-15 (Ie)(220 / 240 V) 4 A
Rated Operational Current AC-15 (Ie)(400 / 440 V) 3 A
Rated Operational Current DC-13 (Ie)(24 V) 6 A / 144 W
Rated Operational Current DC-13 (Ie)(48 V) 2.8 A / 134 W
Rated Operational Current DC-13 (Ie)(72 V) 1 A / 72 W
Rated Operational Current DC-13 (Ie)(110 V) 0.55 A / 60 W
Rated Operational Current DC-13 (Ie)(125 V) 0.55 A / 69 W
Rated Operational Current DC-13 (Ie)(220 V) 0.27 A / 60 W
Rated Operational Current DC-13 (Ie)(250 V) 0.27 A / 68 W
Rated Operational Current DC-13 (Ie)(400 V) 0.15 A / 60 W
Rated Operational Current DC-13 (Ie)(500 V) 0.13 A / 65 W
Rated Operational Current DC-13 (Ie)(600 V) 0.1 A / 60 W
Rated Operational Power AC-3 (Pe)(400 V) 37 kW
Rated Operational Power AC-3 (Pe)(415 V) 45 kW
Rated Operational Power AC-3 (Pe)(440 V) 45 kW
Rated Operational Power AC-3 (Pe)(500 V) 45 kW
Rated Operational Power AC-3 (Pe)(690 V) 45 kW
Rated Operational Power AC-3 (Pe)(1000 V) 35 kW
Rated Operational Power AC-3 (Pe)(380 / 400 V) 37 kW
Rated Operational Power AC-3 (Pe)(220 / 230 / 240 V) 22 kW
Rated Operational Power AC-3e (Pe)(415 V) 45 kW
Rated Operational Power AC-3e (Pe)(440 V) 45 kW
Rated Operational Power AC-3e (Pe)(500 V) 45 kW
Rated Operational Power AC-3e (Pe)(690 V) 45 kW
Rated Operational Power AC-3e (Pe)(380 / 400 V) 37 kW
Rated Operational Power AC-3e (Pe)(220 / 230 / 240 V) 22 kW
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 780 A
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 140 A
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 300 A
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1200 A
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 450 A
Rated Short-time Withstand Current Low Voltage (Icw)for 0.1 s 140 A
Rated Short-time Withstand Current Low Voltage (Icw)for 1 s 100 A
Maximum Breaking Capacitycos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1150 A
Maximum Breaking Capacitycos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 750 A
Rated Insulation Voltage (Ui)acc. to IEC 60947-4-1 1000 V
Rated Insulation Voltage (Ui)acc. to IEC 60947-5-1 690 V
Rated Insulation Voltage (Ui)acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)8 kV
Maximum Electrical Switching Frequency(AC-1) 600 cycles per hour
Maximum Electrical Switching Frequency(AC-15) 1200 cycles per hour
Maximum Electrical Switching Frequency(AC-2 / AC-4) 150 cycles per hour
Maximum Electrical Switching Frequency(AC-3) 1200 cycles per hour
Maximum Electrical Switching Frequency(DC-13) 900 cycles per hour
Maximum Mechanical Switching Frequency3600 cycles per hour
Rated Control Circuit Voltage (Uc)50 Hz 100 ... 250 V
Rated Control Circuit Voltage (Uc)60 Hz 100 ... 250 V
Rated Control Circuit Voltage (Uc)DC Operation 100 ... 250 V
Power Lossat 6 A per Pole 0.1 W
Power Lossat Rated Operating Conditions AC-1 per Pole 7.6 W
Power Lossat Rated Operating Conditions AC-3 per Pole 3 W
Operate TimeBetween Coil De-energization and NC Contact Closing 19 ... 105 ms
Operate TimeBetween Coil De-energization and NO Contact Opening 17 ... 100 ms
Operate TimeBetween Coil Energization and NC Contact Opening 38 ... 95 ms
Operate TimeBetween Coil Energization and NO Contact Closing 42 ... 100 ms
Mounting on DIN RailTH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied) 2 x M4 or 2 x M6 Screws Placed Diagonally
Connecting Capacity Main CircuitFlexible with Ferrule 1/2x 6 ... 50 mm²
Connecting Capacity Main CircuitFlexible with Insulated Ferrule 1/2x 6 ... 50 mm²
Connecting Capacity Main CircuitRigid Stranded 1x 6 ... 70 mm²
Connecting Capacity Main CircuitRigid Stranded 2x 6 ... 50 mm²
Connecting Capacity Auxiliary CircuitFlexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Connecting Capacity Auxiliary CircuitFlexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Connecting Capacity Auxiliary CircuitFlexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Connecting Capacity Auxiliary CircuitRigid 1/2x 1 ... 2.5 mm²
Connecting Capacity Control CircuitFlexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Connecting Capacity Control CircuitFlexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Connecting Capacity Control CircuitFlexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Connecting Capacity Control CircuitRigid 1/2x 1 ... 2.5 mm²
Wire Stripping LengthAuxiliary Circuit 10 mm
Wire Stripping LengthControl Circuit 10 mm
Wire Stripping LengthMain Circuit 17 mm
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Tightening torqueAuxiliary Circuit 1.2 N·m
Tightening torqueControl Circuit 1.2 N·m
Tightening torqueMain Circuit 6 N·m
Terminal TypeScrew Terminals
Product NameBlock Contactor

Technical UL/CSA

NEMA Size3
Continuous Current Rating NEMA90 A
Horsepower Rating NEMA(200 V AC) Three Phase 25 Hp
Horsepower Rating NEMA(230 V AC) Three Phase 30 Hp
Horsepower Rating NEMA(460 V AC) Three Phase 50 Hp
Horsepower Rating NEMA(575 V AC) Three Phase 50 Hp
Maximum Operating Voltage UL/CSAMain Circuit 600 V
General Use Rating UL/CSA(600 V AC) 105 A
Connecting Capacity Main Circuit UL/CSARigid Stranded 1/2x 6-1 AWG
Tightening Torque UL/CSAAuxiliary Circuit 11 in·lb
Tightening Torque UL/CSAControl Circuit 11 in·lb
Tightening Torque UL/CSAMain Circuit 53 in·lb
Full Load Amps Motor Use(120 V AC) Single Phase 7-1/2 A
Full Load Amps Motor Use(200 ... 208 V AC) Three Phase 25 A
Full Load Amps Motor Use(220 ... 240 V AC) Three Phase 30 A
Full Load Amps Motor Use(240 V AC) Single Phase 15 A
Full Load Amps Motor Use(440 ... 480 V AC) Three Phase 60 A
Full Load Amps Motor Use(550 ... 600 V AC) Three Phase 75 A

ABB EcoSolutions

ABB EcoSolutionsYes
End Of Life Disassembling Instructions1SBC101081M6801
Environmental Product Declaration - EPD1SBD250584E1000

Why Proax for ABB AF80N3-30-11-13?

Proax is an authorized distributor of ABB AF80N3-30-11-13 and one of ABB's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Alternate NamesAF80N3301113
Pack Size1
Recommended

CAD$568.26

Not in stock

Request lead time or order—we'll ensure quick delivery

ABB Availability