By ABB
SKU
MPN
1SFL637001R6911
Weight
15.719 kg
Series AF 3-pole Contactor Series
The AF750-30-11-69 is a 3 pole - 1000 V IEC or 600 V UL contactor with pre-mounted auxiliary contacts and Main Circuit Bars, controlling motors up to 400 kW / 400 V AC (AC-3) or 600 hp / 480 V UL and switching power circuits up to 1050 A (AC-1) or 900 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (48-130 V 50/60 Hz and DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.
AF 3-pole Contactor Series
ABB's AF series includes a variety of 3-pole contactors designed for controlling 3-phase motors and power circuits. These contactors are categorized into several sub-series based on their current ratings and applications.
Each sub-series features integrated electronic coils that reduce energy consumption by up to 80%, provide surge protection, and allow operation across wide voltage ranges without coil changes. ABB also offers auxiliary contact blocks and accessories to enhance functionality
Technical Specifications
Dimensions
Product Net Width | 210 mm |
Product Net Depth / Length | 242 mm |
Product Net Height | 283 mm |
Product Net Weight | 13.6 kg |
Technical
Number of Main Contacts NO | 3 |
Number of Main Contacts NC | 0 |
Number of Auxiliary Contacts NO | 1 |
Number of Auxiliary Contacts NC | 1 |
Rated Operational Voltage | Main Circuit 1000 V |
Rated Frequency (f) | Main Circuit 50 / 60 Hz |
Conventional Free-air Thermal Current (Ith) | acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 1050 A |
Rated Operational Current AC-1 (Ie) | (1000 V) 40 °C 1000 A |
Rated Operational Current AC-1 (Ie) | (1000 V) 55 °C 875 A |
Rated Operational Current AC-1 (Ie) | (1000 V) 70 °C 720 A |
Rated Operational Current AC-1 (Ie) | (690 V) 40 °C 1050 A |
Rated Operational Current AC-1 (Ie) | (690 V) 55 °C 875 A |
Rated Operational Current AC-1 (Ie) | (690 V) 70 °C 720 A |
Rated Operational Current AC-3 (Ie) | (415 V) 55 °C 750 A |
Rated Operational Current AC-3 (Ie) | (440 V) 55 °C 750 A |
Rated Operational Current AC-3 (Ie) | (500 V) 55 °C 750 A |
Rated Operational Current AC-3 (Ie) | (690 V) 55 °C 650 A |
Rated Operational Current AC-3 (Ie) | (1000 V) 55 °C 300 A |
Rated Operational Current AC-3 (Ie) | (380 / 400 V) 55 °C 750 A |
Rated Operational Current AC-3 (Ie) | (220 / 230 / 240 V) 55 °C 750 A |
Rated Operational Power AC-3 (Pe) | (415 V) 425 kW |
Rated Operational Power AC-3 (Pe) | (440 V) 450 kW |
Rated Operational Power AC-3 (Pe) | (500 V) 520 kW |
Rated Operational Power AC-3 (Pe) | (690 V) 600 kW |
Rated Operational Power AC-3 (Pe) | (1000 V) 400 kW |
Rated Operational Power AC-3 (Pe) | (380 / 400 V) 400 kW |
Rated Operational Power AC-3 (Pe) | (220 / 230 / 240 V) 220 kW |
Rated Breaking Capacity AC-3 | 8 x Ie AC-3 |
Rated Making Capacity AC-3 | 10 x Ie AC-3 |
Short-Circuit Protective Devices | gG Type Fuses 1000 A |
Rated Short-time Withstand Current Low Voltage (Icw) | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 6400 A |
Rated Short-time Withstand Current Low Voltage (Icw) | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 1300 A |
Rated Short-time Withstand Current Low Voltage (Icw) | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 3500 A |
Rated Short-time Withstand Current Low Voltage (Icw) | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 7000 A |
Rated Short-time Withstand Current Low Voltage (Icw) | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 4500 A |
Maximum Breaking Capacity | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 7500 A |
Maximum Breaking Capacity | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 7000 A |
Maximum Electrical Switching Frequency | (AC-1) 300 cycles per hour |
Maximum Electrical Switching Frequency | (AC-2 / AC-4) 60 cycles per hour |
Maximum Electrical Switching Frequency | (AC-3) 300 cycles per hour |
Rated Operational Current DC-1 (Ie) | (110 V) 1-Pole, 40 °C 1050 A |
Rated Operational Current DC-1 (Ie) | (110 V) 2 Poles in Series, 40 °C 1050 A |
Rated Operational Current DC-1 (Ie) | (220 V) 3 Poles in Series, 40 °C 1050 A |
Rated Operational Current DC-1 (Ie) | (600 V) 3 Poles in Series, 40 °C 1050 A |
Rated Operational Current DC-1 (Ie) | (850 V) 3 Poles in Series, 40 °C 1050 A |
Rated Operational Current DC-3 (Ie) | (110 V) 1-Pole, 40 °C 1050 A |
Rated Operational Current DC-3 (Ie) | (110 V) 2 Poles in Series, 40 °C 1050 A |
Rated Operational Current DC-3 (Ie) | (220 V) 3 Poles in Series, 40 °C 1050 A |
Rated Operational Current DC-3 (Ie) | (600 V) 3 Poles in Series, 40 °C 1050 A |
Rated Operational Current DC-3 (Ie) | (850 V) 3 Poles in Series, 40 °C 1050 A |
Rated Operational Current DC-5 (Ie) | (110 V) 1-Pole, 40 °C 1050 A |
Rated Operational Current DC-5 (Ie) | (110 V) 2 Poles in Series, 40 °C 1050 A |
Rated Operational Current DC-5 (Ie) | (220 V) 3 Poles in Series, 40 °C 1050 A |
Rated Operational Current DC-5 (Ie) | (600 V) 3 Poles in Series, 40 °C 1050 A |
Rated Operational Current DC-5 (Ie) | (850 V) 3 Poles in Series, 40 °C 1050 A |
Rated Insulation Voltage (Ui) | acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V |
Rated Insulation Voltage (Ui) | acc. to UL/CSA 600 V |
Rated Impulse Withstand Voltage (Uimp) | Main Circuit 8 kV |
Mechanical Durability | 3 million |
Maximum Mechanical Switching Frequency | 300 cycles per hour |
Coil Operating Limits | (acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C) |
Rated Control Circuit Voltage (Uc) | 50 Hz 48 ... 130 V |
Rated Control Circuit Voltage (Uc) | 60 Hz 48 ... 130 V |
Rated Control Circuit Voltage (Uc) | DC Operation 48 ... 130 V |
Coil Consumption | Holding at Max. Rated Control Circuit Voltage 50 Hz 12 V·A |
Coil Consumption | Holding at Max. Rated Control Circuit Voltage 60 Hz 12 V·A |
Coil Consumption | Holding at Max. Rated Control Circuit Voltage DC 5 V·A |
Coil Consumption | Pull-in at Max. Rated Control Circuit Voltage 50 Hz 1100 V·A |
Coil Consumption | Pull-in at Max. Rated Control Circuit Voltage 60 Hz 1100 V·A |
Coil Consumption | Pull-in at Max. Rated Control Circuit Voltage DC 1020 V·A |
Operate Time | Between Coil De-energization and NC Contact Closing 50 ... 70 ms |
Operate Time | Between Coil De-energization and NO Contact Opening 53 ... 73 ms |
Operate Time | Between Coil Energization and NC Contact Opening 45 ... 115 ms |
Operate Time | Between Coil Energization and NO Contact Closing 50 ... 120 ms |
Connecting Capacity Main Circuit | Bar 52 mm² |
Connecting Capacity Main Circuit | Rigid Al-Cable 3x185 mm² |
Connecting Capacity Main Circuit | Rigid Cu-Cable 300 mm² |
Connecting Capacity Auxiliary Circuit | Flexible with Ferrule 2x 0.75 ... 2.5 mm² |
Connecting Capacity Auxiliary Circuit | Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm² |
Connecting Capacity Auxiliary Circuit | Flexible 2x0.75 ... 2.5 mm² |
Connecting Capacity Auxiliary Circuit | Solid 2 x 1 ... 4 mm² |
Connecting Capacity Auxiliary Circuit | Stranded 1 x 1 .... 4 mm² |
Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 |
Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00 |
Terminal Type | Main Circuit: Bars |
Technical UL/CSA
NEMA Size | 7 |
Horsepower Rating NEMA | (230 V AC) Three Phase 300 Hp |
Horsepower Rating NEMA | (460 V AC) Three Phase 600 Hp |
Horsepower Rating NEMA | (575 V AC) Three Phase 600 Hp |
Maximum Operating Voltage UL/CSA | Main Circuit 1000 V |
General Use Rating UL/CSA | (1000 V AC) 900 A |
General Use Rating UL/CSA | (600 V AC) 900 A |
Horsepower Rating UL/CSA | (200 V AC) Three Phase 250 hp |
Horsepower Rating UL/CSA | (208 V AC) Three Phase 250 hp |
Horsepower Rating UL/CSA | (220 ... 240 V AC) Three Phase 300 hp |
Horsepower Rating UL/CSA | (440 ... 480 V AC) Three Phase 600 hp |
Horsepower Rating UL/CSA | (550 ... 600 V AC) Three Phase 700 hp |
Why Proax for ABB AF750-30-11-69?
Proax is an authorized distributor of ABB AF750-30-11-69 and one of ABB's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Alternate Names | AF750301169 |
Pack Size | 1 |
Recommended