Technical Specifications

Dimensions

Product Net Width90 mm
Product Net Depth / Length102.5 mm
Product Net Height104 mm
Product Net Weight0.742 kg

Technical

Number of Main Contacts NO3
Number of Main Contacts NC0
Number of Auxiliary Contacts NO2
Number of Auxiliary Contacts NC2
Number of Poles3P
StandardsIEC/EN 60947-1, IEC/EN 60947-4-1, UL 60335-2-40 LZGH2 A2L, UL 60947-4-1, CSA C22.2 No. 60335-2-40 LZGH2 A2L, CSA C22.2 No. 60947-4-1
Rated Operational VoltageAuxiliary Circuit 690 V
Rated Operational VoltageMain Circuit 690 V
Rated Frequency (f)Auxiliary Circuit 50 / 60 Hz
Rated Frequency (f)Control Circuit 50 / 60 Hz
Rated Frequency (f)Main Circuit 50 / 60 Hz
Rated Operational Current AC-1 (Ie)(1000 V) 60 °C 28 A
Rated Operational Current AC-1 (Ie)(690 V) 40 °C 28 A
Rated Operational Current AC-1 (Ie)(690 V) 70 °C 24 A
Rated Operational Current AC-3 (Ie)(415 V) 60 °C 12 A
Rated Operational Current AC-3 (Ie)(440 V) 60 °C 12 A
Rated Operational Current AC-3 (Ie)(500 V) 60 °C 12.5 A
Rated Operational Current AC-3 (Ie)(690 V) 60 °C 9 A
Rated Operational Current AC-3 (Ie)(380 / 400 V) 60 °C 12 A
Rated Operational Current AC-3 (Ie)(220 / 230 / 240 V) 60 °C 12 A
Rated Operational Current AC-3e (Ie)(415 V) 60 °C 12 A
Rated Operational Current AC-3e (Ie)(440 V) 60 °C 12 A
Rated Operational Current AC-3e (Ie)(500 V) 60 °C 12.5 A
Rated Operational Current AC-3e (Ie)(690 V) 60 °C 9 A
Rated Operational Current AC-3e (Ie)(380 / 400 V) 60 °C 12 A
Rated Operational Current AC-3e (Ie)(220 / 230 / 240 V) 60 °C 12 A
Rated Operational Current AC-15 (Ie)(500 V) 2 A
Rated Operational Current AC-15 (Ie)(690 V) 2 A
Rated Operational Current AC-15 (Ie)(24 / 127 V) 6 A
Rated Operational Current AC-15 (Ie)(220 / 240 V) 4 A
Rated Operational Current AC-15 (Ie)(400 / 440 V) 3 A
Rated Operational Current DC-13 (Ie)(24 V) 6 A / 144 W
Rated Operational Current DC-13 (Ie)(48 V) 2.8 A / 134 W
Rated Operational Current DC-13 (Ie)(72 V) 1 A / 72 W
Rated Operational Current DC-13 (Ie)(110 V) 0.55 A / 60 W
Rated Operational Current DC-13 (Ie)(125 V) 0.55 A / 69 W
Rated Operational Current DC-13 (Ie)(220 V) 0.27 A / 60 W
Rated Operational Current DC-13 (Ie)(250 V) 0.27 A / 68 W
Rated Operational Current DC-13 (Ie)(400 V) 0.15 A / 60 W
Rated Operational Current DC-13 (Ie)(500 V) 0.13 A / 65 W
Rated Operational Current DC-13 (Ie)(600 V) 0.1 A / 60 W
Rated Operational Power AC-3 (Pe)(415 V) 5.5 kW
Rated Operational Power AC-3 (Pe)(440 V) 5.5 kW
Rated Operational Power AC-3 (Pe)(500 V) 7.5 kW
Rated Operational Power AC-3 (Pe)(690 V) 7.5 kW
Rated Operational Power AC-3 (Pe)(380 / 400 V) 5.5 kW
Rated Operational Power AC-3 (Pe)(220 / 230 / 240 V) 3 kW
Rated Operational Power AC-3e (Pe)(415 V) 5.5 kW
Rated Operational Power AC-3e (Pe)(440 V) 5.5 kW
Rated Operational Power AC-3e (Pe)(500 V) 7.5 kW
Rated Operational Power AC-3e (Pe)(690 V) 7.5 kW
Rated Operational Power AC-3e (Pe)(380 / 400 V) 5.5 kW
Rated Operational Power AC-3e (Pe)(220 / 230 / 240 V) 3 kW
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 150 A
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 35 A
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 60 A
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 300 A
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 80 A
Rated Short-time Withstand Current Low Voltage (Icw)for 0.1 s 140 A
Rated Short-time Withstand Current Low Voltage (Icw)for 1 s 100 A
Maximum Breaking Capacitycos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 A
Maximum Breaking Capacitycos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 106 A
Rated Insulation Voltage (Ui)acc. to IEC 60947-4-1 690 V
Rated Insulation Voltage (Ui)acc. to IEC 60947-5-1 690 V
Rated Insulation Voltage (Ui)acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)6 kV
Maximum Electrical Switching Frequency(AC-15) 1200 cycles per hour
Maximum Electrical Switching Frequency(DC-13) 900 cycles per hour
Rated Control Circuit Voltage (Uc)50 Hz 24 ... 60 V
Rated Control Circuit Voltage (Uc)60 Hz 24 ... 60 V
Rated Control Circuit Voltage (Uc)DC Operation 20 ... 60 V
Power Lossat 6 A per Pole 0.1 W
Power Lossat Rated Operating Conditions AC-1 per Pole 1 W
Power Lossat Rated Operating Conditions AC-3 per Pole 0.2 W
Mounting on DIN RailTH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
Mounting on DIN RailTH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied) 2 x M4 Screws Placed Diagonally
Connecting Capacity Main CircuitFlexible with Ferrule 1/2x 0.75 ... 6 mm²
Connecting Capacity Main CircuitFlexible with Insulated Ferrule 1x 0.75 ... 4 mm²
Connecting Capacity Main CircuitFlexible with Insulated Ferrule 2x 0.75 ... 2.5 mm²
Connecting Capacity Main CircuitRigid Solid 1/2x 1 ... 4 mm²
Connecting Capacity Main CircuitRigid Stranded 1/2x 1 ... 6 mm²
Connecting Capacity Auxiliary CircuitRigid Solid 1/2x 1 ... 2.5 mm²
Connecting Capacity Auxiliary CircuitRigid Stranded 1/2x 1 ... 2.5 mm²
Connecting Capacity Control CircuitFlexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Connecting Capacity Control CircuitFlexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Connecting Capacity Control CircuitFlexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Connecting Capacity Control CircuitRigid Solid 1/2x 1 ... 2.5 mm²
Connecting Capacity Control CircuitRigid Stranded 1/2x 1 ... 2.5 mm²
Wire Stripping LengthAuxiliary Circuit 10 mm
Wire Stripping LengthControl Circuit 10 mm
Wire Stripping LengthMain Circuit 10 mm
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
Tightening torqueAuxiliary Circuit 1.2 N·m
Tightening torqueControl Circuit 1.2 N·m
Tightening torqueMain Circuit 1.5 N·m
Terminal TypeScrew Terminals
Product NameContactor Starter

Technical UL/CSA

Maximum Operating Voltage UL/CSAMain Circuit 600 V
Connecting Capacity Main Circuit UL/CSARigid Solid 1/2x 16-10 AWG
Connecting Capacity Main Circuit UL/CSARigid Stranded 1/2x 16-10 AWG
Connecting Capacity Auxiliary Circuit UL/CSARigid Solid 1/2x 18-14 AWG
Connecting Capacity Auxiliary Circuit UL/CSARigid Stranded 1/2x 18-14 AWG
Connecting Capacity Control Circuit UL/CSARigid Solid 1/2x 18-14 AWG
Connecting Capacity Control Circuit UL/CSARigid Stranded 1/2x 18-14 AWG
Tightening Torque UL/CSAAuxiliary Circuit 11 in·lb
Tightening Torque UL/CSAControl Circuit 11 in·lb
Tightening Torque UL/CSAMain Circuit 13 in·lb

Why Proax for ABB AF12ZR-30-22-21?

Proax is an authorized distributor of ABB AF12ZR-30-22-21 and one of ABB's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Alternate NamesAF12ZR302221
Pack Size1
Recommended

CAD$535.50

Not in stock

Request lead time or order—we'll ensure quick delivery

ABB Availability