0.27 kg
The AF12-30-10-11 is a 3 pole - 690 V IEC or 600 UL contactor with 1 built-in auxiliary contact and screw terminals, controlling motors up to 5.5 kW / 400 V AC (AC-3) or 7-1/2 hp / 480 V UL and switching power circuits up to 28 A (AC-1) or 28 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (24-60 V 50/60 Hz and 20-60 V DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.

AF 3-pole Contactors

ABB's AF series includes a variety of 3-pole contactors designed for controlling 3-phase motors and power circuits. These contactors are categorized into several sub-series based on their current ratings and applications.

Each sub-series features integrated electronic coils that reduce energy consumption by up to 80%, provide surge protection, and allow operation across wide voltage ranges without coil changes. ABB also offers auxiliary contact blocks and accessories to enhance functionality

Technical Specifications

Supplier Information - BRAPR001

Configuration OnlyNo
Country or Territory of OriginFrance
CriticalityNo
Lead Time19 day
Made to OrderNo
NoteNo
Product Availability ClassFrom stock if available, otherwise Target delivery time is
Product Sales StatusActive
Quote OnlyNo
Stocked At WarehousesBRAPR001EXPU
Storage Location4001
Warranty ReturnProduct under warranty must be returned

Supplier Information - CHNOR001

Configuration OnlyNo
Country or Territory of OriginFrance
CriticalityNo
Lead Time0 day
Made to OrderNo
NoteNo
Product Availability ClassFrom stock if available, otherwise Target delivery time is
Product Sales StatusActive
Quote OnlyNo
Stocked At WarehousesCHNOR001EXPU
Storage Location4001
Warranty ReturnProduct under warranty must be returned

Supplier Information - CLABB001

Configuration OnlyNo
Country or Territory of OriginFrance
CriticalityNo
Lead Time19 day
Made to OrderNo
NoteNo
Product Availability ClassFrom stock if available, otherwise Target delivery time is
Product Sales StatusActive
Quote OnlyNo
Stocked At WarehousesCLABB001EXPU
Storage Location4001
Warranty ReturnProduct under warranty must be returned

Supplier Information - CNIAB001

NoteNo
Country or Territory of OriginFrance
CriticalityNo
Lead Time19 day
Made to OrderNo
Product Availability ClassFrom stock if available, otherwise Target delivery time is
Product Sales StatusActive
Quote OnlyNo
Stocked At WarehousesCNIAB001EXPU
Storage Location4001

Supplier Information - COABB001

Country or Territory of OriginFrance
CriticalityNo
Lead Time19 day
Made to OrderNo
Warranty ReturnProduct under warranty must be returned
NoteNo
Product Availability ClassFrom stock if available, otherwise Target delivery time is
Product Sales StatusActive
Quote OnlyNo
Stocked At WarehousesCOABB001EXPU
Storage Location4001

Supplier Information - DEAPRMLC

Configuration OnlyNo
Country or Territory of OriginFrance
CriticalityNo
Lead Time0 day
Made to OrderNo
NoteNo
Product Availability ClassFrom stock if available, otherwise Target delivery time is
Product Sales StatusActive
Quote OnlyNo
Stocked At WarehousesDEAPRMLCEXPU
Storage Location4001
Warranty ReturnProduct under warranty must be returned

Supplier Information - DKSER001

Configuration OnlyNo
Country or Territory of OriginFrance
CriticalityNo
Lead Time19 day
Made to OrderNo
NoteNo
Product Availability ClassFrom stock if available, otherwise Target delivery time is
Product Sales StatusActive
Quote OnlyNo
Stocked At WarehousesDKSER001EXPU
Storage Location4001
Warranty ReturnProduct under warranty must be returned

Supplier Information - DUABB001

Configuration OnlyNo
Country or Territory of OriginFrance
CriticalityNo
Lead Time19 day
Made to OrderNo
NoteNo
Product Availability ClassFrom stock if available, otherwise Target delivery time is
Product Sales StatusActive
Quote OnlyNo
Stocked At WarehousesDUABB001EXPU
Storage Location4001
Warranty ReturnProduct under warranty must be returned

Supplier Information - DUABB003

Configuration OnlyNo
Country or Territory of OriginFrance
CriticalityNo
Lead Time19 day
Made to OrderNo
NoteNo
Product Availability ClassFrom stock if available, otherwise Target delivery time is
Product Sales StatusActive
Quote OnlyNo
Stocked At WarehousesDUABB003EXPU
Storage Location4001
Warranty ReturnProduct under warranty must be returned

Supplier Information - EESER001

Configuration OnlyNo
Country or Territory of OriginFrance
CriticalityNo
Lead Time19 day
Made to OrderNo
NoteNo
Product Availability ClassFrom stock if available, otherwise Target delivery time is
Product Sales StatusActive
Quote OnlyNo
Stocked At WarehousesEESER001EXPU
Storage Location4001
Warranty ReturnProduct under warranty must be returned

Supplier Information - EGAUT001

Configuration OnlyNo
Country or Territory of OriginFrance
CriticalityNo
Lead Time19 day
Made to OrderNo
NoteNo
Product Availability ClassFrom stock if available, otherwise Target delivery time is
Product Sales StatusActive
Quote OnlyNo
Stocked At WarehousesEGAUT001EXPU
Storage Location4001
Warranty ReturnProduct under warranty must be returned

Supplier Information - ESATD001

Configuration OnlyNo
Country or Territory of OriginFrance
CriticalityNo
Lead Time19 day
Made to OrderNo
NoteNo
Product Availability ClassFrom stock if available, otherwise Target delivery time is
Product Sales StatusActive
Quote OnlyNo
Stocked At WarehousesESATD001EXPU
Storage Location4001
Warranty ReturnProduct under warranty must be returned

Supplier Information - FIPSE

NoteNo
Product Availability ClassFrom stock if available, otherwise Target delivery time is
Lead Time19 day
Country or Territory of OriginFrance

Supplier Information - FISER001

Configuration OnlyNo
Country or Territory of OriginFrance
CriticalityNo
Lead Time0 day
Made to OrderNo
NoteNo
Product Availability ClassFrom stock if available, otherwise Target delivery time is
Product Sales StatusActive
Quote OnlyNo
Stocked At WarehousesFISER001EXPU
Storage Location4001
Warranty ReturnProduct under warranty must be returned

Supplier Information - FRAUT001

Configuration OnlyNo
Country or Territory of OriginFrance
CriticalityNo
Lead Time19 day
Made to OrderNo
NoteNo
Product Availability ClassFrom stock if available, otherwise Target delivery time is
Product Sales StatusActive
Quote OnlyNo
Stocked At WarehousesFRAUT001EXPU
Storage Location4001
Warranty ReturnProduct under warranty must be returned

Supplier Information - GBINS001

Configuration OnlyNo
Country or Territory of OriginFrance
CriticalityNo
Lead Time19 day
Made to OrderNo
NoteNo
Product Availability ClassFrom stock if available, otherwise Target delivery time is
Product Sales StatusActive
Quote OnlyNo
Stocked At WarehousesGBINS001EXPU
Storage Location4001
Warranty ReturnProduct under warranty must be returned

Supplier Information - GRABB001

Configuration OnlyNo
Country or Territory of OriginFrance
CriticalityNo
Lead Time19 day
Made to OrderNo
NoteNo
Product Availability ClassFrom stock if available, otherwise Target delivery time is
Product Sales StatusActive
Quote OnlyNo
Stocked At WarehousesGRABB001EXPU
Storage Location4001
Warranty ReturnProduct under warranty must be returned

Supplier Information - INABB039

Country or Territory of OriginFrance
CriticalityNo
Lead Time19 day
Made to OrderNo
NoteNo
Product Availability ClassFrom stock if available, otherwise Target delivery time is
Product Sales StatusActive
Quote OnlyNo
Stocked At WarehousesINABB039EXPU
Storage Location4001
Warranty ReturnProduct under warranty must be returned

Supplier Information - INABBRLC

Configuration OnlyNo
Country or Territory of OriginFrance
CriticalityNo
Lead Time19 day
Made to OrderNo
NoteNo
Product Availability ClassFrom stock if available, otherwise Target delivery time is
Product Sales StatusActive
Quote OnlyNo
Stocked At WarehousesINABBRLCEXPU
Storage Location4001
Warranty ReturnProduct under warranty must be returned

Supplier Information - ITIND002

Configuration OnlyNo
Country or Territory of OriginFrance
CriticalityNo
Lead Time19 day
Made to OrderNo
NoteNo
Product Availability ClassFrom stock if available, otherwise Target delivery time is
Product Sales StatusActive
Quote OnlyNo
Stocked At WarehousesITIND002EXPU
Storage Location4001
Warranty ReturnProduct under warranty must be returned

Supplier Information - NLABB021

Configuration OnlyNo
Country or Territory of OriginFrance
CriticalityNo
Lead Time19 day
Made to OrderNo
NoteNo
Product Availability ClassFrom stock if available, otherwise Target delivery time is
Product Sales StatusActive
Quote OnlyNo
Stocked At WarehousesNLABB021EXPU
Storage Location4001
Warranty ReturnProduct under warranty must be returned

Supplier Information - NOATDRLC

Configuration OnlyNo
Country or Territory of OriginFrance
CriticalityNo
Lead Time19 day
Made to OrderNo
NoteNo
Product Availability ClassFrom stock if available, otherwise Target delivery time is
Product Sales StatusActive
Quote OnlyNo
Stocked At WarehousesNOATDRLCEXPU
Storage Location4001
Warranty ReturnProduct under warranty must be returned

Supplier Information - SGIND002

Configuration OnlyNo
Country or Territory of OriginFrance
CriticalityNo
Lead Time19 day
Made to OrderNo
NoteNo
Product Availability ClassFrom stock if available, otherwise Target delivery time is
Product Sales StatusActive
Quote OnlyNo
Stocked At WarehousesSGIND002EXPU
Storage Location4001
Warranty ReturnProduct under warranty must be returned

Supplier Information - TRDMD001

Country or Territory of OriginFrance
CriticalityNo
Lead Time19 day
Made to OrderNo
Warranty ReturnProduct under warranty must be returned
NoteNo
Product Availability ClassFrom stock if available, otherwise Target delivery time is
Product Sales StatusActive
Quote OnlyNo
Stocked At WarehousesTRDMD001EXPU
Storage Location4001

Supplier Information - USABB251

Country or Territory of OriginFrance
CriticalityNo
Lead Time19 day
Made to OrderNo
NoteNo
Product Availability ClassFrom stock if available, otherwise Target delivery time is
Product Sales StatusActive
Quote OnlyNo
Stocked At WarehousesUSABB251EXPU
Storage Location4001
Warranty ReturnProduct under warranty must be returned

Supplier Information - ZATAD021

Configuration OnlyNo
Country or Territory of OriginFrance
CriticalityNo
Lead Time0 day
Made to OrderNo
NoteNo
Product Availability ClassFrom stock if available, otherwise Target delivery time is
Product Sales StatusActive
Quote OnlyNo
Stocked At WarehousesZATAD021EXPU
Storage Location4001
Warranty ReturnProduct under warranty must be returned

Dimensions

Product Net Width45 mm
Product Net Depth / Length77 mm
Product Net Height86 mm
Product Net Weight0.27 kg

Technical

Number of Main Contacts NO3
Number of Main Contacts NC0
Number of Auxiliary Contacts NO1
Number of Auxiliary Contacts NC0
Number of Poles3P
StandardsIEC/EN 60947-1, IEC/EN 60947-4-1, UL 60335-2-40 LZGH2 A2L, UL 60947-4-1, CSA C22.2 No. 60335-2-40 LZGH2 A2L, CSA C22.2 No. 60947-4-1
Rated Operational VoltageAuxiliary Circuit 690 V
Rated Operational VoltageMain Circuit 690 V
Rated Frequency (f)Auxiliary Circuit 50 / 60 Hz
Rated Frequency (f)Control Circuit 50 / 60 Hz
Rated Frequency (f)Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 35 A
Conventional Free-air Thermal Current (Ith)acc. to IEC 60947-5-1, Θ = 40 °C 16 A
Rated Operational Current AC-1 (Ie)(690 V) 40 °C 28 A
Rated Operational Current AC-1 (Ie)(690 V) 60 °C 28 A
Rated Operational Current AC-1 (Ie)(690 V) 70 °C 24 A
Rated Operational Current AC-3 (Ie)(415 V) 60 °C 12 A
Rated Operational Current AC-3 (Ie)(440 V) 60 °C 12 A
Rated Operational Current AC-3 (Ie)(500 V) 60 °C 12.5 A
Rated Operational Current AC-3 (Ie)(690 V) 60 °C 9 A
Rated Operational Current AC-3 (Ie)(380 / 400 V) 60 °C 12 A
Rated Operational Current AC-3 (Ie)(220 / 230 / 240 V) 60 °C 12 A
Rated Operational Current AC-3e (Ie)(415 V) 60 °C 12 A
Rated Operational Current AC-3e (Ie)(440 V) 60 °C 12 A
Rated Operational Current AC-3e (Ie)(500 V) 60 °C 12.5 A
Rated Operational Current AC-3e (Ie)(690 V) 60 °C 9 A
Rated Operational Current AC-3e (Ie)(380 / 400 V) 60 °C 12 A
Rated Operational Current AC-3e (Ie)(220 / 230 / 240 V) 60 °C 12 A
Rated Operational Current AC-15 (Ie)(500 V) 2 A
Rated Operational Current AC-15 (Ie)(690 V) 2 A
Rated Operational Current AC-15 (Ie)(24 / 127 V) 6 A
Rated Operational Current AC-15 (Ie)(220 / 240 V) 4 A
Rated Operational Current AC-15 (Ie)(400 / 440 V) 3 A
Rated Operational Current DC-1 (Ie)(110 V) 1-Pole, 40 °C 15 A
Rated Operational Current DC-1 (Ie)(110 V) 1-Pole, 60 °C 15 A
Rated Operational Current DC-1 (Ie)(110 V) 1-Pole, 70 °C 15 A
Rated Operational Current DC-1 (Ie)(110 V) 2 Poles in Series, 40 °C 27 A
Rated Operational Current DC-1 (Ie)(110 V) 2 Poles in Series, 60 °C 27 A
Rated Operational Current DC-1 (Ie)(110 V) 2 Poles in Series, 70 °C 24 A
Rated Operational Current DC-1 (Ie)(110 V) 3 Poles in Series, 40 °C 27 A
Rated Operational Current DC-1 (Ie)(110 V) 3 Poles in Series, 60 °C 27 A
Rated Operational Current DC-1 (Ie)(110 V) 3 Poles in Series, 70 °C 24 A
Rated Operational Current DC-1 (Ie)(220 V) 2 Poles in Series, 40 °C 15 A
Rated Operational Current DC-1 (Ie)(220 V) 2 Poles in Series, 60 °C 15 A
Rated Operational Current DC-1 (Ie)(220 V) 2 Poles in Series, 70 °C 15 A
Rated Operational Current DC-1 (Ie)(220 V) 3 Poles in Series, 40 °C 27 A
Rated Operational Current DC-1 (Ie)(220 V) 3 Poles in Series, 60 °C 27 A
Rated Operational Current DC-1 (Ie)(220 V) 3 Poles in Series, 70 °C 24 A
Rated Operational Current DC-1 (Ie)(72 V) 1-Pole, 40 °C 27 A
Rated Operational Current DC-1 (Ie)(72 V) 1-Pole, 60 °C 27 A
Rated Operational Current DC-1 (Ie)(72 V) 1-Pole, 70 °C 24 A
Rated Operational Current DC-1 (Ie)(72 V) 2 Poles in Series, 40 °C 27 A
Rated Operational Current DC-1 (Ie)(72 V) 2 Poles in Series, 60 °C 27 A
Rated Operational Current DC-1 (Ie)(72 V) 2 Poles in Series, 70 °C 24 A
Rated Operational Current DC-1 (Ie)(72 V) 3 Poles in Series, 40 °C 27 A
Rated Operational Current DC-1 (Ie)(72 V) 3 Poles in Series, 60 °C 27 A
Rated Operational Current DC-1 (Ie)(72 V) 3 Poles in Series, 70 °C 24 A
Rated Operational Current DC-3 (Ie)(110 V) 1-Pole, 40 °C 7 A
Rated Operational Current DC-3 (Ie)(110 V) 1-Pole, 60 °C 7 A
Rated Operational Current DC-3 (Ie)(110 V) 1-Pole, 70 °C 7 A
Rated Operational Current DC-3 (Ie)(110 V) 2 Poles in Series, 40 °C 27 A
Rated Operational Current DC-3 (Ie)(110 V) 2 Poles in Series, 60 °C 27 A
Rated Operational Current DC-3 (Ie)(110 V) 2 Poles in Series, 70 °C 24 A
Rated Operational Current DC-3 (Ie)(110 V) 3 Poles in Series, 40 °C 27 A
Rated Operational Current DC-3 (Ie)(110 V) 3 Poles in Series, 60 °C 27 A
Rated Operational Current DC-3 (Ie)(110 V) 3 Poles in Series, 70 °C 24 A
Rated Operational Current DC-3 (Ie)(220 V) 2 Poles in Series, 40 °C 7 A
Rated Operational Current DC-3 (Ie)(220 V) 2 Poles in Series, 60 °C 7 A
Rated Operational Current DC-3 (Ie)(220 V) 2 Poles in Series, 70 °C 7 A
Rated Operational Current DC-3 (Ie)(220 V) 3 Poles in Series, 40 °C 27 A
Rated Operational Current DC-3 (Ie)(220 V) 3 Poles in Series, 60 °C 27 A
Rated Operational Current DC-3 (Ie)(220 V) 3 Poles in Series, 70 °C 24 A
Rated Operational Current DC-3 (Ie)(72 V) 1-Pole, 40 °C 27 A
Rated Operational Current DC-3 (Ie)(72 V) 1-Pole, 60 °C 27 A
Rated Operational Current DC-3 (Ie)(72 V) 1-Pole, 70 °C 24 A
Rated Operational Current DC-3 (Ie)(72 V) 2 Poles in Series, 40 °C 27 A
Rated Operational Current DC-3 (Ie)(72 V) 2 Poles in Series, 60 °C 27 A
Rated Operational Current DC-3 (Ie)(72 V) 2 Poles in Series, 70 °C 24 A
Rated Operational Current DC-3 (Ie)(72 V) 3 Poles in Series, 40 °C 27 A
Rated Operational Current DC-3 (Ie)(72 V) 3 Poles in Series, 60 °C 27 A
Rated Operational Current DC-3 (Ie)(72 V) 3 Poles in Series, 70 °C 24 A
Rated Operational Current DC-5 (Ie)(110 V) 1-Pole, 40 °C 4 A
Rated Operational Current DC-5 (Ie)(110 V) 1-Pole, 60 °C 4 A
Rated Operational Current DC-5 (Ie)(110 V) 1-Pole, 70 °C 4 A
Rated Operational Current DC-5 (Ie)(110 V) 2 Poles in Series, 40 °C 15 A
Rated Operational Current DC-5 (Ie)(110 V) 2 Poles in Series, 60 °C 15 A
Rated Operational Current DC-5 (Ie)(110 V) 2 Poles in Series, 70 °C 15 A
Rated Operational Current DC-5 (Ie)(110 V) 3 Poles in Series, 40 °C 27 A
Rated Operational Current DC-5 (Ie)(110 V) 3 Poles in Series, 60 °C 27 A
Rated Operational Current DC-5 (Ie)(110 V) 3 Poles in Series, 70 °C 24 A
Rated Operational Current DC-5 (Ie)(220 V) 2 Poles in Series, 40 °C 4 A
Rated Operational Current DC-5 (Ie)(220 V) 2 Poles in Series, 60 °C 4 A
Rated Operational Current DC-5 (Ie)(220 V) 2 Poles in Series, 70 °C 4 A
Rated Operational Current DC-5 (Ie)(220 V) 3 Poles in Series, 40 °C 12 A
Rated Operational Current DC-5 (Ie)(220 V) 3 Poles in Series, 60 °C 12 A
Rated Operational Current DC-5 (Ie)(220 V) 3 Poles in Series, 70 °C 12 A
Rated Operational Current DC-5 (Ie)(72 V) 1-Pole, 40 °C 12 A
Rated Operational Current DC-5 (Ie)(72 V) 1-Pole, 60 °C 12 A
Rated Operational Current DC-5 (Ie)(72 V) 1-Pole, 70 °C 12 A
Rated Operational Current DC-5 (Ie)(72 V) 2 Poles in Series, 40 °C 27 A
Rated Operational Current DC-5 (Ie)(72 V) 2 Poles in Series, 60 °C 27 A
Rated Operational Current DC-5 (Ie)(72 V) 2 Poles in Series, 70 °C 24 A
Rated Operational Current DC-5 (Ie)(72 V) 3 Poles in Series, 40 °C 27 A
Rated Operational Current DC-5 (Ie)(72 V) 3 Poles in Series, 60 °C 27 A
Rated Operational Current DC-5 (Ie)(72 V) 3 Poles in Series, 70 °C 24 A
Rated Operational Current DC-13 (Ie)(24 V) 6 A / 144 W
Rated Operational Current DC-13 (Ie)(48 V) 2.8 A / 134 W
Rated Operational Current DC-13 (Ie)(72 V) 1 A / 72 W
Rated Operational Current DC-13 (Ie)(110 V) 0.55 A / 60 W
Rated Operational Current DC-13 (Ie)(125 V) 0.55 A / 69 W
Rated Operational Current DC-13 (Ie)(220 V) 0.27 A / 60 W
Rated Operational Current DC-13 (Ie)(250 V) 0.27 A / 68 W
Rated Operational Current DC-13 (Ie)(400 V) 0.15 A / 60 W
Rated Operational Current DC-13 (Ie)(500 V) 0.13 A / 65 W
Rated Operational Current DC-13 (Ie)(600 V) 0.1 A / 60 W
Rated Operational Power AC-3 (Pe)(400 V) 5.5 kW
Rated Operational Power AC-3 (Pe)(415 V) 5.5 kW
Rated Operational Power AC-3 (Pe)(440 V) 5.5 kW
Rated Operational Power AC-3 (Pe)(500 V) 7.5 kW
Rated Operational Power AC-3 (Pe)(690 V) 7.5 kW
Rated Operational Power AC-3 (Pe)(380 / 400 V) 5.5 kW
Rated Operational Power AC-3 (Pe)(220 / 230 / 240 V) 3 kW
Rated Operational Power AC-3e (Pe)(415 V) 5.5 kW
Rated Operational Power AC-3e (Pe)(440 V) 5.5 kW
Rated Operational Power AC-3e (Pe)(500 V) 7.5 kW
Rated Operational Power AC-3e (Pe)(690 V) 7.5 kW
Rated Operational Power AC-3e (Pe)(380 / 400 V) 5.5 kW
Rated Operational Power AC-3e (Pe)(220 / 230 / 240 V) 3 kW
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 150 A
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 35 A
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 60 A
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 300 A
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 80 A
Rated Short-time Withstand Current Low Voltage (Icw)for 0.1 s 140 A
Rated Short-time Withstand Current Low Voltage (Icw)for 1 s 100 A
Maximum Breaking Capacitycos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 A
Maximum Breaking Capacitycos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 106 A
Rated Insulation Voltage (Ui)acc. to IEC 60947-4-1 690 V
Rated Insulation Voltage (Ui)acc. to IEC 60947-5-1 690 V
Rated Insulation Voltage (Ui)acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)6 kV
Maximum Electrical Switching Frequency(AC-1) 600 cycles per hour
Maximum Electrical Switching Frequency(AC-15) 1200 cycles per hour
Maximum Electrical Switching Frequency(AC-2 / AC-4) 300 cycles per hour
Maximum Electrical Switching Frequency(AC-3) 1200 cycles per hour
Maximum Electrical Switching Frequency(DC-13) 900 cycles per hour
Maximum Mechanical Switching Frequency3600 cycles per hour
Rated Control Circuit Voltage (Uc)50 Hz 24 ... 60 V
Rated Control Circuit Voltage (Uc)60 Hz 24 ... 60 V
Rated Control Circuit Voltage (Uc)DC Operation 20 ... 60 V
Power Lossat 6 A per Pole 0.1 W
Power Lossat Rated Operating Conditions AC-1 per Pole 1 W
Power Lossat Rated Operating Conditions AC-3 per Pole 0.2 W
Operate TimeBetween Coil De-energization and NC Contact Closing 13 ... 98 ms
Operate TimeBetween Coil De-energization and NO Contact Opening 11 ... 95 ms
Operate TimeBetween Coil Energization and NC Contact Opening 38 ... 90 ms
Operate TimeBetween Coil Energization and NO Contact Closing 40 ... 95 ms
Mounting on DIN RailTH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
Mounting on DIN RailTH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied) 2 x M4 Screws Placed Diagonally
Connecting Capacity Main CircuitFlexible with Ferrule 1/2x 0.75 ... 6 mm²
Connecting Capacity Main CircuitFlexible with Insulated Ferrule 1x 0.75 ... 4 mm²
Connecting Capacity Main CircuitFlexible with Insulated Ferrule 2x 0.75 ... 2.5 mm²
Connecting Capacity Main CircuitRigid Solid 1/2x 1 ... 4 mm²
Connecting Capacity Main CircuitRigid Stranded 1/2x 1 ... 6 mm²
Connecting Capacity Auxiliary CircuitFlexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Connecting Capacity Auxiliary CircuitFlexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Connecting Capacity Auxiliary CircuitFlexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Connecting Capacity Auxiliary CircuitRigid Solid 1/2x 1 ... 2.5 mm²
Connecting Capacity Auxiliary CircuitRigid Stranded 1/2x 1 ... 2.5 mm²
Connecting Capacity Control CircuitFlexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Connecting Capacity Control CircuitFlexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Connecting Capacity Control CircuitFlexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Connecting Capacity Control CircuitRigid Solid 1/2x 1 ... 2.5 mm²
Connecting Capacity Control CircuitRigid Stranded 1/2x 1 ... 2.5 mm²
Wire Stripping LengthAuxiliary Circuit 10 mm
Wire Stripping LengthControl Circuit 10 mm
Wire Stripping LengthMain Circuit 10 mm
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
Tightening torqueAuxiliary Circuit 1.2 N·m
Tightening torqueControl Circuit 1.2 N·m
Tightening torqueMain Circuit 1.5 N·m
Terminal TypeScrew Terminals
Product NameBlock Contactor

Technical UL/CSA

NEMA Size0
Continuous Current Rating NEMA18 A
Horsepower Rating NEMA(115 V AC) Single Phase 1 Hp
Horsepower Rating NEMA(200 V AC) Three Phase 3 Hp
Horsepower Rating NEMA(230 V AC) Single Phase 2 Hp
Horsepower Rating NEMA(230 V AC) Three Phase 3 Hp
Horsepower Rating NEMA(460 V AC) Three Phase 5 Hp
Horsepower Rating NEMA(575 V AC) Three Phase 5 Hp
Maximum Operating Voltage UL/CSAMain Circuit 600 V
General Use Rating UL/CSA(600 V AC) 28 A
Horsepower Rating UL/CSA(120 V AC) Single Phase 1 hp
Horsepower Rating UL/CSA(200 ... 208 V AC) Three Phase 3 hp
Horsepower Rating UL/CSA(220 ... 240 V AC) Three Phase 3 hp
Horsepower Rating UL/CSA(240 V AC) Single Phase 2 hp
Horsepower Rating UL/CSA(440 ... 480 V AC) Three Phase 7-1/2 hp
Horsepower Rating UL/CSA(550 ... 600 V AC) Three Phase 10 hp
Connecting Capacity Main Circuit UL/CSARigid Solid 1/2x 16-10 AWG
Connecting Capacity Main Circuit UL/CSARigid Stranded 1/2x 16-10 AWG
Connecting Capacity Auxiliary Circuit UL/CSARigid Solid 1/2x 18-14 AWG
Connecting Capacity Auxiliary Circuit UL/CSARigid Stranded 1/2x 18-14 AWG
Connecting Capacity Control Circuit UL/CSARigid Solid 1/2x 18-14 AWG
Connecting Capacity Control Circuit UL/CSARigid Stranded 1/2x 18-14 AWG
Tightening Torque UL/CSAAuxiliary Circuit 11 in·lb
Tightening Torque UL/CSAControl Circuit 11 in·lb
Tightening Torque UL/CSAMain Circuit 13 in·lb
Full Load Amps Motor Use(120 V AC) Single Phase 16 A
Full Load Amps Motor Use(200 ... 208 V AC) Three Phase 11 A
Full Load Amps Motor Use(220 ... 240 V AC) Three Phase 9.6 A
Full Load Amps Motor Use(240 V AC) Single Phase 12 A
Full Load Amps Motor Use(440 ... 480 V AC) Three Phase 11 A
Full Load Amps Motor Use(550 ... 600 V AC) Three Phase 11 A

ABB EcoSolutions

End Of Life Disassembling Instructions1SBC101080M6801
Environmental Product Declaration - EPD1SBD250584E3000
Environmental Product Declaration - EPD2TFP200035A1001
Sustainable Material Content in Packaging (wt. %)Recycled Cardboard - 86 %
Sustainable Material Content in Product (wt. %)Recycled Metal - 28 %

Why Proax for ABB AF12-30-10-11?

Proax is an authorized distributor of ABB AF12-30-10-11 and one of ABB's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Alternate NamesAF12301011
Pack Size1
Recommended

Not in stock

Request lead time or order—we'll ensure quick delivery

ABB Availability